12
Technical data
12.1
Controller
Note
Values specified for system voltages of 12 V, 24 V and 48 V are specified below separated by a "/"
character.
MPPT 6000
Characterisation of the operating behaviour
System voltage
12 V / 24 V / 48 V (automatic detection)
Rated output
850 W / 1700 W / 3400 W
Max. MPP efficiency
> 99.8 %
Max. DC/DC efficiency
> 98.5 %
Own consumption
In operation: 2 W; standby: < 1 W
DC input side
Max. input voltage
1) 2)
200 VDC
Module current
1) 2)
2 x 30 A
MPP voltage/string
> 1.15 x V
bat
up to 180 V
Open circuit solar module/string voltage
20 ... 200 V (at minimum operating temperature)
DC output side
Max. charging current
60 A
Float charge completion of charging
voltage
Factory setting
14.1 VDC / 28.2 VDC / 56.4 VDC
Setting range
12.6 VDC ... 14.4 VDC / 25.2 VDC ... 28.8 VDC /
50.4 VDC ... 57.6 VDC
Boost charge switch-on threshold
SOC
3)
| Voltage control
Factory setting
70 % | 12.7 V / 25.4 V / 50.8 V
Setting range
40 % ... 70 % | 11.4 VDC ... 12.7 VDC /
22.8 VDC ... 25.4 VDC / 45.6 VDC ... 50.8 VDC
Boost charge completion of charging
voltage
Factory setting
14.4 VDC / 28.8 VDC / 57.6 VDC
Setting range
13.2 VDC ... 15.6 VDC / 26.4 VDC ... 31.2 VDC /
52.8 VDC ... 62.4 VDC
Boost charge duration
Factory setting
120 min
GB
749.126 | M02 | 2013-11-13
38