Micro-Inverter
English
INV250-45EU RS485
INV250-45EU PLC
INV250-45EU
INV350-60EU RS485
INV350-60EU PLC
INV350-60EU
INV500-90EU RS485
INV500-90EU PLC
INV500-90EU
Страница 1: ...Micro Inverter English INV250 45EU RS485 INV250 45EU PLC INV250 45EU INV350 60EU RS485 INV350 60EU PLC INV350 60EU INV500 90EU RS485 INV500 90EU PLC INV500 90EU ...
Страница 2: ...ng instructions INV250 45EU RS485 INV250EU 45 PLC and INV250EU 45 INV350 60EU RS485 INV350EU 60 PLC and INV350EU 60 INV500 90EU RS485 INV500EU 90 PLC and INV500EU 90 Printed in Germany Copyright by AEconversion GmbH Co KG ...
Страница 3: ...tion 8 7 1 Installation on PV racking 9 7 2 Mounting alternatives 9 8 0 Connections 9 8 1 Overview of connections 10 8 1 1 Connection areas of the inverter PLC NOCOM 10 8 1 2 Connection areas of the RS485 inverter 10 8 2 AC connection 10 8 2 1 AC connections of the inverter PLC NOCOM 11 8 2 2 AC connections of the inverter RS485 11 8 3 DC connection 11 8 4 Communication setup 12 8 4 1 RS485 commun...
Страница 4: ...tions of all parts and components of the system 2 1 General information and safety instructions The proper and safe operation of this device requires proper transport storage installation and assembly as well as careful operation and maintenance When operating this equipment certain parts of the equipment are under dangerous voltage which can cause serious bodily injury or death Therefore please f...
Страница 5: ...odies and force majeure lightning overvoltage thunderstorms fire Insufficient or non existent ventilation of the unit Non observance of safety regulations Transport damage Use of non original PV mating plugs and sockets from the HELIOS H4 product series by Amphenol If you mount the inverters at a great height avoid possible risks of falling Do not insert any electrically conductive parts into the ...
Страница 6: ...nd designed for operating temperatures from 25 C to 70 C If the temperature inside the enclosure exceeds a certain value the inverter automatically regulates the maximum power to protect itself Systems with micro inverters are easy to design and install Each inverter can be mounted on the mounting rack underneath the PV modules but it is recommended to have a place where emergency service work can...
Страница 7: ...t within tolerance range LED 1sec ON 0 75sec OFF 0 25sec 3 cycles AC and DC voltages not within tolerance range LED 1sec ON 0 75sec OFF 0 25sec 4 cycles Internal overtemperature LED 1sec ON 0 75sec OFF 0 25sec 5 cycles Sequence ends 2 sec AUS Insulation measurement on the PV side In feed in operation a too low insulation resistance between PV and AC side is signalled with a fast flashing For this ...
Страница 8: ... 90V for INV500 UMpp 60 C min input voltage 20 VDC for INV250 20 VDC for INV350 60 40 VDC for INV350 90 40 VDC für INV500 For INV250 45EU this voltage is 20 V For INV350 60EU this voltage is 20 V For INV350 90EU this voltage is 40 V For INV500 90EU this voltage is 40 V The UMpp Voltage of the connected string should not fall below the allowed input voltage range even at very high module temperatur...
Страница 9: ... an example slot stones can be fastened to the mounting profiles at the positions below the inverter brackets with screws When mounting make sure that the inverter is mounted in the correct installation position the cover must face upwards connection plugs must point downwards 7 2 Installation alternative If mounting on the mounting frame below the PV modules is not possible another mounting alter...
Страница 10: ...he line length is long on the AC side the voltage at the mains terminals of the inverter increases during feed in operation This voltage is measured by the inverter If the voltage at the grid terminals exceeds the limit for grid overvoltage the inverter switches off due to grid overvoltage This circumstance must be taken into account in the AC wiring and when dimensioning the AC line When using se...
Страница 11: ...nections is correct Check the PV generator for earth connection before connecting it to the inverter Only use original mating plugs and sockets from the HELIOS H4 product range from Amphenol Observe the Amphenol assembly instructions for the DC connectors if you assemble the cables yourself Check that the PV generator is free of earth faults before connecting it to the inverter Before connecting t...
Страница 12: ...e functions that may be required from the legal requirements or technical guidelines from chapter 4 For the selection of the correct data logger please contact your specialist dealer With the inverters the external power limitation is implemented via the RS485 interface To establish communication we recommend a twisted and shielded data cable of type Cat 5 T568B Using the following pre assembled i...
Страница 13: ...nction Description of the inverter or Declaration of conformity and clearance certificate Information on the short circuit resistance of the switching devices 10 0 Switching off the inverter You must switch off the inverter for adjustment maintenance and repair work Proceed as follows Switch off the mains voltage deactivate the external fuse elements After switching off check that there is no volt...
Страница 14: ...t and dirt 12 3 Laws regulations and technical rules When constructing solar installations the laws and regulations applicable to the respective country at state federal and European or international level must be observed In general the generally recognised rules of technology apply which are usually formulated in the form of standards guidelines regulations provisions and technical rules by stat...
Страница 15: ...fficiency Maximum efficiency 93 5 European efficiency 91 4 MPP efficiency 99 8 Mechanical data Operating temperature range 25 C 70 C Nightly energy consumption 30 mW Max Operating altitude above sea level 2000 m DC connector MC4 compatible Dimensions WxHxD 314 mm x 267 mm x 66 5 mm Weight 2 5 kg Cooling Natural convection Enclosure material Aluminium Enclosure protection class IP65 50Hz version NE...
Страница 16: ...ficiency Maximum efficiency 93 5 European efficiency 91 8 MPP efficiency 99 8 Mechanical data Operating temperature range 25 C 70 C Nightly energy consumption 30 mW Max Operating altitude above sea level 2000 m DC connector MC4 compatible Dimensions WxHxD 314 mm x 267 mm x 66 5 mm Weight 2 5 kg Cooling Natural convection Enclosure material Aluminium Enclosure protection class IP65 50Hz version NEM...
Страница 17: ...ficiency Maximum efficiency 95 0 European efficiency 93 6 MPP efficiency 99 8 Mechanical data Operating temperature range 25 C 70 C Nightly energy consumption 30 mW Max Operating altitude above sea level 2000 m DC connector MC4 compatible Dimensions WxHxD 314 mm x 267 mm x 66 5 mm Weight 2 5 kg Cooling Natural convection Enclosure material Aluminium Enclosure protection class IP65 50Hz version NEM...
Страница 18: ...ficiency Maximum efficiency 95 0 European efficiency 94 0 MPP efficiency 99 8 Mechanical data Operating temperature range 25 C 70 C Nightly energy consumption 30 mW Max Operating altitude above sea level 2000 m DC connector MC4 compatible Dimensions WxHxD 314 mm x 267 mm x 66 5 mm Weight 2 5 kg Cooling Natural convection Enclosure material Aluminium Enclosure protection class IP65 50Hz version NEM...
Страница 19: ...19 02 2020 INV250 INV350 INV500 Overview Country specific data 250W 350W 500W ...
Страница 20: ...20 INV250 INV350 INV500 02 2020 Derating Ppv T ambient 0m s Wind speed Derating P pv I pv Derating Ppv T ambient 0 1 m s Wind speed Derating diagrams for INV250 ...
Страница 21: ...21 02 2020 INV250 INV350 INV500 Derating diagrams for INV350 60 Derating Ppv T ambient 0m s Wind speed Derating P pv I pv Leistungsreduzierung Ppv T ambient 0 1 m s Wind speed ...
Страница 22: ...22 INV250 INV350 INV500 02 2020 Derating diagrams for INV350 90 and INV500 90 Derating Ppv T ambient 0m s Wind speed Derating P pv I pv Derating Ppv T ambient 0 1 m s Wind speed ...
Страница 23: ...23 02 2020 INV250 INV350 INV500 Derating diagrams for INV350 90 and INV500 90 Derating P pv U ac ...
Страница 24: ...24 INV250 INV350 INV500 02 2020 Konformitätserklärung ...
Страница 25: ...25 02 2020 INV250 INV350 INV500 AEconversion GmbH Co KG An der Helle 26 59495 Bad Sassendorf Germany Telefon 49 0 2927 9194 10 Telefax 49 0 2927 9194 50 www aeconversion de ...