AE Conversion INV-EU Series Скачать руководство пользователя страница 1

turn over

- Mark the appropriate center of each PV 

module on the framework for inverter 

placement.

- Attach the Micro-Inverter using hardware 

accessories that are suitable for the framework 

used in the PV System, i.e. screws and sliding 

blocks. 

- Ensure a minimum distance of 20 mm between 

the roof top and the bottom of the inverter. 

In addition, a distance of 25 mm between 

the back of the PV module and the top of the 

inverter should be complied with.

- Connect the RJ45 connector with the RS-485 

interface of the inverter. All unused ports must 

be closed with a protective cap.

- The last RJ45 socket must be terminated with a 

120 Ω terminating plug.

- The end of the RS-485 cable can be connected 

to a data logging system.

- Make a note of the serial numbers of each 

inverter and the corresponding PV module. 

It will help you later to create an overview of 

your PV system.

- Connect the PV module to the Micro-Inverter 

using the DC Cabling.

- Switch in the circuit breaker to energize the AC 

line.

1

2

3

4

This Quick Manual provides basic information for the installation of the 

AEconversion Micro-Inverter. For detailed information, please refer to the 

Installation Manual provided on CD. 

WARNING! 

All electrical installations must be done by in compliance with local and national 

electrical codes. 

CE Mark

The CE mark documents that according to the label the inverter fulfills the 

following essential requirements of relevant directives:

· Directive on the Electromagnetic Compatibility with the Directive 2004/108/EC 

 · Low Voltage Directive (Directive 2006/95/EC)

Accessories needed

P

” - Included   /   “

O

” - not included in scope of delivery

1 - Mounting accessories for PV racking system

2 - Cover for female AC connector

2

 - Male connector with strain relief

2

 - Female connector with strain relief 

2

 - Connection Cable

3 - RJ45 connector / terminating plug (14-05-500422-1)

5 - PV-modules including male and female connector Amphenol H4 

O
P
O

O
O
O

EU/50Hz/230V 

Installations:

16A Circuit Breaker

Non-EU/50Hz/230V 
Installations:

16A Circuit Breaker

Non-EU/50Hz/230V 
Installations:

20A Circuit Breaker

Type of inverter

Max. number of inverters in one branch

INV250-45 EU

12

12

15

INV350-60 EU

9

9

11

INV350-90 EU

9

9

11

INV500-90 EU

6

6

8

- Connect the last Micro-Inverter to the next one   

using AC connector cabling and continue with 

following inverters.

- Ensure that the maximum allowable number 

of inverters is not exceeded in one branch.  

(see table)

- Any unused AC Connectors must be covered 

with an end cap.

- The end of the AC wire of one branch must 

be switched to a circuit breaker with a current 

rating of 16A (20A) and a characteristic of type 

B. (see table)

QUICK MANUAL - INV-EU RS485