85 mm {3-11/32 inches}
(85.7 mm {3-3/8 inches})
ø
25.4 mm
{
ø
1 inch}
*5
85 mm
{3-11/32 inches}
(85.7 mm
{3-3/8 inches})
138 mm
{5-7/16 inches}
ø
25.4 mm
{
ø
1 inch}
*5
138 mm
{5-7/16 inches}
83.5 mm
{3-9/32 inches}
46 mm
{1-13/16 inches}
ø
25.4 mm
{
ø
1 inch}
*5
63 mm
{2-15/32 inches}
ø
25.4 mm
{
ø
1 inch}
*5
63 mm
{2-15/32 inches}
83.5 mm
{3-9/32 inches}
ø
25.4 mm
{
ø
1 inch}
*5
108.5 mm
{4-9/32 inches}
70 mm
{2-3/4 inches}
ø
25.4 mm
{
ø
1 inch}
*5
Position A
Position D
Position B
Position C
Position E
Position F
Attachment plate (accessory)
Fixing screws for attachment plate: x4 (M4, locally procured)
Two-gang junction box
46 mm {1-13/16 inches}
83.5 mm {3-9/32 inches}
Installation
Step2 Fixing the brackets
Step1 Preparations
The installation tasks are explained using 4 steps.
There are 3 methods to install the camera to a ceiling or wall as described below. Prepare the
required parts for each installation method before starting the installation. The following are the
requirements for the various installation methods.
Installation method
Recommended
screw
Minimum pull-out
strength (per 1 pc.)
[1] Mount the camera on the two-gang junction
box using the attachment plate.
M4 screws x 4
196 N {44 lbf}
[2] Directly mount the camera onto the ceiling or
wall using the attachment plate (when wiring
can be installed in the ceiling or wall).
M4 screws x 4
196 N {44 lbf}
[3] Mount the camera onto the ceiling or wall using
the base bracket (when conduits are used for
wiring, or when there is no space available for
wiring in the ceiling or the wall).
*1
M4 screws x 4
196 N {44 lbf}
*1 Use 4 screws (M4 × 8 mm, accessory) to fix the attachment plate to the base bracket.
IMPORTANT:
●
Procure 4 screws (M4) to secure the attachment plate (accessory) or base bracket
(accessory) to a ceiling or a wall.
●
The minimum required pull-out capacity of a single screw or anchor bolt is 196 N
{44 lbf} or more when mounting with the installation method [1] to [3] above.
When mounting the camera on a concrete ceiling, use an AY plug bolt (M4) for secur-
ing. (Recommended tightening torque: 1.6 N·m {1.18 lbf·ft})
●
Select screws according to the material of the ceiling or wall that the camera will be
mounted to. In this case, wood screws and nails should not be used.
●
If a ceiling board such as plaster board is too weak to support the total weight, the
area shall be sufficiently reinforced.
[1] Using a two-gang junction box
[2] Directly mount the camera to the ceiling or wall using the attachment plate
[3] Mount the camera to a ceiling or a wall using base bracket
< When using the conduit on the ceiling
or wall for wiring>
The base bracket can be fixed in any of the following 6 screwing positions
according to ceiling and wall conditions. Match the hole used when
installing the camera to any of positions A to F.
<Mounting the base bracket>
①
Remove the cap for the female thread for
the conduit by using a hexagon wrench
(ISO 2936, width across flats S=5 mm
{3/16 inches}).
②
Mount the attachment plate and
the base bracket.
Attachment plate (accessory)
Fixing screws for attach-
ment plate: x4 (M4, locally
procured)
ø25.4 mm
*3
{1 inch}
ø73 mm
*4
{2-7/8 inches}
*5 The wiring hole diameter is 25.4 mm {1 inch}. Select any of the 2 base bracket fixture holes of
Ⓖ
template B when installing the base bracket. After mounting the attachment plate, the mounting direction
of the camera can be adjusted in 90° increments.
*6 When attaching the base bracket to a one-gang junction box in Position E, secure the base bracket
with 2 screws (M4,
locally procured
).
IMPORTANT:
●
If open wiring is conducted, be sure to use conduits and run the cables inside
the tubes to protect the cables from direct sunlight.
●
Installation work shall be such that there is no exposure to water into the
architecture through the conduits having been joined.
Step1
Make sure all items are prepared
before beginning installation.
Step2
Mount the brackets to a ceiling or
wall
Step3
Connect cables, and then attach the
camera to the mount bracket.
Step4
Adjust the angle of view and focus,
and then mount the enclosure.
FRONT
Cap for the female
thread for the con-
duit
Base bracket (accessory)
Fixing screws (M4x4, locally
procured)
Minimum pull-out
strength: 196 N {44.06 lbf}
(per 1 pc.)
Fixing screws for attachment
plate: x4 (accessory)
(Recommended tightening
torque: 0.78 N·m {0.58 lbf·ft})
Attachment plate
(accessory)
*3
If the mounting direction of the camera has already been determined
Align the FRONT direction (the direction of FRONT marker on the camera that indicates the
installation direction when installing the camera) of
Ⓕ
template A with the desired direction, and
drill through a 25.4 mm {1 inch} diameter hole.
*4
If the mounting direction of the camera is not determined yet or if you want to change
the direction of the camera after it has been installed
If you want to be able to change the direction of the camera, drill through a 73 mm {2-7/8 inches}
diameter hole in the center. By doing so you can adjust the mounting direction of the camera in
90° increments.
Step3 Mount the camera to the attachment plate
Step4 Adjustment
①
Check the position of attachment
mounting screws on the rear side
of the camera.
②
Connect cables to the camera according to
the instructions in “Making connections”, and
mount the camera by inserting the attachment
mounting screws into the holes of the attach-
ment plates.
③
Loosen the enclosure fixing screws.
④
Remove the enclosure from the camera,
and secure the camera using camera
fixing screws.
Note:
●
After cables have been connected to the camera, align the OPEN mark of the enclosure
side panel with the protruding part of base bracket, insert 2 attachment mounting screws
into the attachment plate, and rotate the camera approximately 15°. The LOCK mark is
moved to the protruding part of base bracket and the camera is temporarily secured.
(When directly attaching the attachment plate to a ceiling or wall, align the OPEN mark to
the tab position of the attachment plate.)
*The fixing angle of the camera can be rotated in 90° increments
.
Note:
●
Loosen 4 enclosure fixing screws
using the bit (accessory).
IMPORTANT:
●
Be sure to tighten the camera fixing
screw. Failure to observe this may
cause camera trouble due to camera
falling. (Recommended tightening
torque: 0.78 N·m {0.58 lbf·ft})
①
Turn on power for the camera by either
connecting a LAN cable or a 12 V DC
power cable.
②
Connect the MONITOR OUT conversion
plug (accessory) to the MONITOR OUT
terminal of the camera, and then connect
the monitor for adjustment with a RCA pin
cable (locally procured).
●
The camera is set to be connected to the
NTSC monitor for adjustment at factory
shipment.
Horizontal position (Panning):
±
180°
Vertical position (Tilting): 0° to 85°
Image tilt adjustment:
-45°(Left) to +300°(Right)
●
To remove the SD memory card, hold down the SD ON/OFF
button for about 2 seconds. When the flashing SD MOUNT
indicator goes out, you can remove the SD memory card.
●
After the SD memory card has been replaced, press the
SD ON/OFF button, and make sure the SD MOUNT
indicator is continually lit. (If you replace both SD memory
cards, press the SD ON/OFF button after replacing the
cards.)
●
If you do not press the SD ON/OFF button after replacing
the SD memory card, the SD MOUNT indicator is
continually lit approximately 5 minutes later.
●
When adjusting the viewing angle, make sure not
to touch the light-blocking rubber ring or IR LED
cover. Fingerprints or dirt can reduce the quality of
viewed images.
③
Adjust the angle of the camera with the
tilt table, pan table, and azimuth adjust-
ment ring, and then adjust the viewing
angle by pressing the WIDE or TELE
buttons.
④
Insert an SD memory card into the slot,
if necessary.
⑤
Disconnect the monitor for adjustment
after adjusting the focus by pressing the
AF button.
⑥
Attach the enclosure.
(Remove the protection film from inside
of the dome cover, match the protruding
part of base bracket to LOCK mark
of the enclosure, and then attach the
enclosure.)
Ⓔ
MONITOR OUT conversion plug
(accessory)
NTSC
⇔
PAL
WIDE
Note:
●
When the screen size is adjusted using the WIDE
⇔
TELE button, the camera’s focus is
automatically adjusted with the basic focus adjustment function each time the
WIDE
⇔
TELE button is pressed.
●
When mounting the camera on a ceiling, adjust the tilt angle so that the TOP mark above
the lens always comes to the top side.
●
When the camera is installed to a wall, the image is reversed in the default settings. To
correct the way the image is displayed, rotate the azimuth adjustment ring 180° clockwise,
or select “On” for “Upside-down” from the setup menu. For information about performing
the “Upside-down” setting from the setup menu, refer to the Operating Instructions
(included in the CD-ROM).
●
Remove the camera using the reverse order of the installation procedures.
IMPORTANT:
●
Securely tighten all the fixing screws (x4) of enclosure. Otherwise, camera dropping
may result in injury. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft})
●
Defocus may be caused by the reinstalled enclosure. In this case, perform the auto
focus function from the setup menu.
●
Remove the cover film from the dome cover.
Approx. 15°
Enclosure
Camera fixing screw
Attachment mounting screws
IMPORTANT:
●
Disconnect the 12 V DC power source and PoE power source to prevent power from being
supplied during mounting work.
●
Enclosure is fixed at the installation auxiliary wire to the camera body, please do not
remove the installed auxiliary wire.
●
For installations on the wall, to prevent water from accumulating on the surface of the
dehumidifying device, install the camera so that the dehumidifying device does not face up.
If water accumulates on the surface of the dehumidifying device, it cannot function properly.
AF
SD1, SD2
TELE
< When drilling a hole through the
ceiling or wall for wiring>
●
The female thread for conduit is compliant
with ANSI NPSM (parallel pipe threads)
3/4 inches or G3/4 of ISO 228-1.
*
6
After installing the camera, refer to “Configure the settings of the camera (leaflet)” and
perform the camera settings.
Tab position
of the attach-
ment plate
(x4)
Conduit
Protruding part (x4)
Direction marker
for installation
(FRONT )
●
Insert the SD memory card with its label
facing down.
46 mm
{1-13/16 inches}
83.5 mm