Page. 28 of 29
March 2016
Edition 1
PLANAR
6
Tools and Equipment for Maintenance and Repairs.
6.1 Test Stand.
Maintenance and repair of liquid and air heaters is carried out on the stationary test
stand DV 1105.000 (Figure 19) manufactured by OOO ADVERS.
The stand is designed for the following operations:
a)
testing liquid and air heaters using a diagnostic device and determination of their
faults;
b)
checking the performance of a fuel pump, air blower, temperature and overheat
sensors, flame indicator, glow plug;
c)
checking the performance of liquid and air heaters after repairs.
Key features and work procedures on the stand are described in the operation manual
for DV1105.000.
Fig19- Test Stand.
Note.
This stand allows you to perform quick and high quality repairs of liquid and air
heaters.
6.2 USB adapter.
The USB adapteris designed for connecting liquid and air heaters to a personal
computer (PC). It is used to obtain data on the status of the liquid or air heater.
The program starts Planar heaters from computer and reads data from the heaters:
-
start number
,
-
current mode of operation
,
-
software version
,
-
air inlet temperature in °C
,
-
supply voltage in V
,
-
flame indicator value in standard units
,
-
fuel pump frequency in Hz
,
-
electric motor speed.
For more information, refer to the instruction manual of the USB adapter.