- 25 -
www.advateklights.com
PixLite 16 Long Range Mk2 User Manual V210222
9 - Troubleshooting
Generally, troubleshooting requires looking at the LEDs on the control board.
9.1 - LED Codes
Please refer to the table below for condition codes for the onboard status and power
LEDs.
Status LED (Red)
Power LED (Green)
Condition
Flashing
Solid
Normal operation,
Main application running okay
Slow flashing
Solid
Test mode running
Flashing together
Flashing together
Looking for IP address
(DHCP Mode)
Solid
Solid
Main application not running
Off
Solid
Main application not running
Solid
Off
Main application not running
Alternate flashing
Alternate flashing
Bootloader mode
Off
Off
No power
Please refer to the table below for condition codes for the Ethernet jack status LEDs.
Link LED (Green)
Data LED (Yellow)
Condition
Solid
Flashing
Connected okay, receiving data
Solid
Off
Connected okay, no data
Off
Off
No link established
9.2 - No Power/Status LEDs
Ensure that your power supply is supplying correct voltage as per
.
Additionally, ensure that it can supply enough current to drive the lights that are
connected. You should also try disconnecting all outputs and see if the controller then
turns on. If the supplied power is correct, try performing a recovery firmware update
as per