WISE-S100 Series User Manual

2

1.1

General Introduction

WISE-S100 is an easy to install intelligent stack light monitoring sensor to fit a variety

of stack-type light towers.  When  WISE-4000  wireless  modular  I/O  series  is  paired

with WISE-S100 sensor, users get a remote and intelligent OEE solution that can be

integrated  without  stopping  machinery,  or  worrying  about  wiring.  WISE-S100

enhances the productivity and overall equipment effectiveness. It supports WiFi 2.4G

and  various  LPWAN  wireless  technologies  such  as  LoRaWAN  and  proprietary

LPWAN (SUB-G) which has higher penetration, lower interference, wider coverage

and  fits  diverse  production  scenarios  on  the  production  line.  WISE-4000  LPWAN

series come with an optional battery power solution.

1.2

Features & Benefits

One Size Fits a Variety of Machine-Types

There are 8 light sensors inside WISE-S100 tower light. The idea of the design is for
quick and easy installation without needing to stop a machine. All users need to do is

to simply position a sensor indicator at the stack light and adjust WISE-S100 directly

to match each light and mount them together.

No Need to Stop the Machinery While Installation

WISE-S100 is able to detect the light status by light colors, such as light on, light off,

slow blink, and fast blink. It has 8 built-in light sensors for quick installation to fulfill

most tower light applications in the market. Directly position WISE-S100 on the stack-

type light tower to quickly get light status. You do not need to stop machines/equip

-

ment so you can quickly deploy your intelligent OEE solution. 

Intelligent OEE Solution by Wireless Remote Management

By pairing WISE-4051 I/O module and WISE-S100, users can enjoy wireless remote
management including up to 10, 000 data samples of local data storage with time

stamps.  WISE-S100  sends  data  to  SCADA  system,  MES  etc.  via  Modbus  TCP,

RESTful, HTTP and MQTT messaging protocols. The sensors support more than 20

Modbus  addresses  for  intelligent  OEE  applications.  WISE-4000  series  also  have

WiFi, LoRaWAN  and proprietary LPWAN wireless solution  which  support Modbus,

and  MQTT  messaging  protocols  for  remote  management.  With  LPWAN  wireless

technologies, the whole solution can be battery powered with high penetration and

wide coverage for complex production line environments.

Содержание WISE-S100

Страница 1: ...User Manual WISE S100 ...

Страница 2: ...ation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed accordi...

Страница 3: ...pment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with part 15 of the FCC Rules Operation is subject to the foll...

Страница 4: ...le precautions to protect yourself from harm and the products from damage Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are included to help you avoid damaging hardware or losin...

Страница 5: ... liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel 15 The power cord or plug is damaged 16 Liquid has penetrated into the equipment 17 The equipment has been exposed to moisture 18 ...

Страница 6: ...WISE S100 Series User Manual vi ...

Страница 7: ...WISE S100 6 Figure 2 2 Installation of WISE S100 6 Chapter 3 Hardware Specification 7 3 1 Power 8 3 2 Generic 8 3 3 Ambient Light Sensor 8 3 4 Mechanical 8 3 5 Environmental 8 3 6 Cable Wiring and Ping Assignment 9 Table 3 1 WISE S100 Cable Definition 9 Figure 3 1 WISE S100 Connector Pin Assignment 9 Chapter 4 Firmware Specification 11 4 1 Operation Mode 12 4 2 Configuration 14 4 3 Light Sensor Ch...

Страница 8: ...WISE S100 Series User Manual viii ...

Страница 9: ...Chapter 1 1 Product Introduction ...

Страница 10: ...djust WISE S100 directly to match each light and mount them together No Need to Stop the Machinery While Installation WISE S100 is able to detect the light status by light colors such as light on light off slow blink and fast blink It has 8 built in light sensors for quick installation to fulfill most tower light applications in the market Directly position WISE S100 on the stack type light tower ...

Страница 11: ... Industrial Design Figure 1 1 WISE S100 Industrial Design 1 4 Dimension Figure 1 2 WISE S100 Dimension 1 5 LED Indication LED Color Indication Behavior Status Green Steady On Modbus RTU Mode On for 5 secs Serial Bus Mode power saving Blinking 2Hz Sensor Initial Error ...

Страница 12: ...er Manual 4 1 6 Packing List 1 x WISE S100 Stack Light Monitoring Sensor 3 x Plastic Tie 1 x 2m Cable 1 x WISE S100 Startup Manual 1 x China RoHS Declaration Note The 2m cable is installed on WISE S100 in default package ...

Страница 13: ...Chapter 2 2 Hardware Installation ...

Страница 14: ... WISE S100 directly to match each light and mount them together Simply position WISE S100 on the stack type light tower to quickly get light status You do not need to stop machine equipment so you can quickly deploy your intelli gent OEE solution There are only two steps to install the WISE S100 when deployment Step 1 Position the light sensor by the indicator Step 2 Use the plastic tie to fix the...

Страница 15: ...Chapter 3 3 Hardware Specification ...

Страница 16: ...ring Light Status On Off Slow Blink Fast Blink Peak Irradiance 550 nm TYP Spectral Responsivity Resolution 12 bits Accuracy 15 Accuracy of measurement of fluorescent light Linearity Input illuminance 40 lux 2 TYP Input illuminance 40 lux 5 TYP Temperature Drift 0 02 C 3 4 Mechanical Dimension L x W x H 220 x 14 x 12 8 mm Material Polycarbonate PC 3 5 Environmental Operating Temperature 25 70 C Sto...

Страница 17: ...onnected and installed in default package The power input of the sensor is 3 3 30VDC Please refer to the pin assignment via below table Figure 3 1 WISE S100 Connector Pin Assignment Table 3 1 WISE S100 Cable Definition 2M Cable with Wafer Box PN 1700031410 01 1 Red V In 2 Black GND 3 Brown DATA 4 Yellow MCU Interrupt 5 Orange DATA 6 Green IO Interrupt ...

Страница 18: ...WISE S100 Series User Manual 10 ...

Страница 19: ...Chapter 4 4 Firmware Specification ...

Страница 20: ... change to Modbus mode via WISE Studio WISE Studio version needs to be 1 01 01 B05 or above Step 2 Operation Mode Change The way to access WISE S100 in Serial Bus Mode through WISE Studio when switching into Modbus Mode PC ADAM 4561 or any other USB to RS 485 converter WISE S100 Step 3 Check the LED Indicator The LED indicator will be on when WISE S100 is powered on Serial Bus Mode LED indicator w...

Страница 21: ...mation please click into I O status for the device mode and further information Step 5 Modbus Mode Enter into Configuration page through WISE Studio Please take note of your RS 485 setting in case you could not search it Note Please refer to the Modbus Address table for more information ...

Страница 22: ...sen sor Normal Status To support better power saving mode please tick the normal status of the light tower For example the light is usually on please tick normal on Low Illumination Limited Value Lux x means Dark High Illumination Limited Value Lux x means Light Fast Blink Frequency Threshold Frequency x means Fast Blinking Note Tips for better accuracy Please enable Lux reading at the first Recor...

Страница 23: ...mode On Off Blink mode On Off Blink mode Delay time In On Off Blink mode if within delay time the state keeps high low the state becomes high low 1s 5s Unit second 2s Filter How many consecutive events are required to trigger the state implement by sensor 0 disable 1 2 conversion time Disable Illumination option Whether to get illumination 0 disable 1 enable disable Normal state Which state should...

Страница 24: ...e in serial protocol mode Modbus RTU Address not modifiable See Appendix I Values Setting parameters State High Low Slow blink Fast blink Frequency State count Keep last value State duration unit 0 1s Keep last value Illumination Enable option if serial protocol mode LED Color Indication Behavior Status Green Steady On Modbus RTU Mode On for 5 secs Serial Bus Mode power saving Blinking 2Hz Sensor ...

Страница 25: ... series Communi cation between I O module and RF module is via serial bus interface and serial bus protocol The interface of the serial bus is UART and two GPIOs to control the com munication in power saving mode The serial protocol defines the commands for exchanging module information I O configuration and value and upgrading the firm ware of I O module ...

Страница 26: ...WISE S100 Series User Manual 18 ...

Страница 27: ...Appendix A A Modbus Table ...

Страница 28: ...dis able 0xFD Read Read 40024 8 Read 40025 1 Frequency hundredfold Read Read 40032 8 Read 40033 40034 1 Low state count Read Read 40047 40048 8 Read 00033 1 Clear low state count Write 40049 40050 1 High state count Read Write Read 00040 8 Write 40063 40064 8 Read 00041 1 Clear high state count Write 40065 40066 1 Slow Blink state count Read Write Read 00048 8 Write 40079 40080 8 Read 00049 1 Clea...

Страница 29: ...k state total time 100 ms Read Write Read 00080 8 Write 40143 40144 8 Read 00081 1 Clear slow blink state total time Write 40145 40146 1 Fast Blink state total time 100 ms Read Write Read 00088 8 Write 40159 40160 8 Read 00089 1 Clear fast blink state total time Write 40211 Module Name 1 Read Write 40212 Module Name 2 Read 00096 8 Write 40213 Module Name 3 Read 40214 Reserved for Module Name Read ...

Страница 30: ...4 Read 01041 Clear high state count only enabled channel Write 41065 41066 Slow Blink state count only enabled channel Read Write Read 01048 Write 41079 41080 Read 01049 Clear slow blink state count only enabled channel Write 41081 41082 Fast Blink state count only enabled channel Read Write Read 01056 Write 41095 41096 Read 01057 Clear fast blink state count only enabled channel Write 41097 41098...

Страница 31: ...r channel3 and 41005 for channel 1 sensor status 01073 Clear high state total time only enabled channel Write 41129 41130 Slow Blink state total time only enabled channel 100 ms Read Write Read 01080 Write 41143 41144 Read 01081 Clear slow blink state total time only enabled channel Write 41145 41146 Fast Blink state total time only enabled channel 100 ms Read Write Read 01088 Write 41159 41160 Re...

Страница 32: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2020 ...