background image

2  WISE-4671 Startup Manual

6.  Press 

Connect

 to link WISE-4671 and you will see the web configuration page.

7. 

Use web configuration in WISE Utility or press 

Open in Browser

 to open the web configuration in any browser (Google 

Chrome is recommended).

8.  Click 

Information

 to check whether your module has successfully connected to a Cat.NB1/Cat.M1 network. 

Pin Assignment of WISE-S600 I/O Module with M12 Connectors 

M12 

Connector

Model Name

M12 Cable

WISE-S672

WISE-S614

WISE-S615

WISE-S617

Pin Number

PCB P/N

4Pin : 1700028162-01 

8Pin : 1700028163-01

19A3DC7200-01 19A3DB1402-01 19A3DC1500-01

19A3DC1702-01

A

1

White

DI 0

DI 0

RTD0+

AI 0+

2

Brown

DI 1

DI 1

RTD0-

AI 0-

3

Green

DI 2

DI 2

RTD0 COM

+12V Out0

4

Yellow

DI 3

DI 3

NC

+12V Out GND

5

Gray

DI 4

NC

RTD1+

AI 1+

6

Pink

DI 5

NC

RTD1-

AI 1-

7

Blue

NC

NC

RTD1 COM

+12V Out1

8

Red

DI COM

DI COM

NC

+12V Out GND

  

Application Wiring

  Quick Start for WISE-4671 Series (Cont.)

LUCOM GmbH    —   Flößaustr. 22a   —   90763 Fürth   —   Tel.:  +49 911/ 957 606 00   —   E-Mail: [email protected]   —   www.lucom.de

www

.lucom.de

Содержание WISE-4671

Страница 1: ...he below I O module should be selected and ordered respectively to be paired with WISE 4671 Selected I O Module to be paired with WISE 4671 WISE S614 4AI 4DI with M12 Connectors WISE S614T 4AI 4DI with Terminal Block WISE S615 4RTD with M12 Connectors WISE S617 2AI 2DI 1DO 1RS 485 with M12 Connectors WISE S617T 2AI 2DI 1DO 1RS 485 with Terminal Block WISE S672 6DI 1RS 485 1RS 485 or RS 232 with M1...

Страница 2: ...ectors M12 Connector Model Name M12 Cable WISE S672 WISE S614 WISE S615 WISE S617 Pin Number PCB P N 4Pin 1700028162 01 8Pin 1700028163 01 19A3DC7200 01 19A3DB1402 01 19A3DC1500 01 19A3DC1702 01 A 1 White DI 0 DI 0 RTD0 AI 0 2 Brown DI 1 DI 1 RTD0 AI 0 3 Green DI 2 DI 2 RTD0 COM 12V Out0 4 Yellow DI 3 DI 3 NC 12V Out GND 5 Gray DI 4 NC RTD1 AI 1 6 Pink DI 5 NC RTD1 AI 1 7 Blue NC NC RTD1 COM 12V O...

Страница 3: ...2 TX AI 1 RTD2 COM DI COM 4 Yellow RS 232 RX AI 1 NC DO 0 5 Gray DATA1 AI 2 RTD3 DO GND 6 Pink DATA1 AI 2 RTD3 RS 485 D 7 Blue NC AI 3 RTD3 COM RS 485 D 8 Red RS 232 GND AI 3 NC RS 485 GND PWR 1 Brown VS VS VS VS 2 White VS VS VS VS 3 Blue SP SP SP SP 4 Black NC SP SP SP Application Wiring of WISE S600 Series I O Module with M12 Connectors WISE S614 4AI 4DI Application Wiring Cont LUCOM GmbH Flößa...

Страница 4: ...er Connector RTD 0 White 1 A RTD 0 Brown 2 COM 0 Green 3 NC Yellow 4 RTD 1 Gray 5 RTD 1 Pink 6 COM 1 Blue 7 NC Red 8 RTD 2 White 1 B RTD 2 Brown 2 COM 2 Green 3 NC Yellow 4 RTD 3 Gray 5 RTD 3 Pink 6 COM 3 Blue 7 NC Red 8 Vs Brown 1 PWR Vs White 2 Solar Panel V Blue 3 Solar Panel V Black 4 Application Wiring Cont LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lu...

Страница 5: ...ng Cont WISE S672 6DI 1RS 485 1RS 485 or 1RS 232 Application Wiring of WISE S600T Series I O Module with Terminal Block WISE S614T 4AI 4DI LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 6: ...7T 2AI 2DI 1DO 1RS 485 Install the CP210x USB to UART controller driver USB does not power the module Application Wiring Cont Notes LUCOM GmbH Flößaustr 22a 90763 Fürth Tel 49 911 957 606 00 E Mail info lucom de www lucom de www lucom de ...

Страница 7: ...672 WISE S614 etc with the WISE 4671 module There are three ways to power up the WISE module battery power solar panel power and line power Open the rubber cover on the side of the WISE module and you can see a battery switch for turning on off the battery power For solar power it is not only to recharge the battery but also to power up the device Refer to the application wiring section for solar ...

Страница 8: ...d error with 3rd Good signal strength LED 2 Hz blink ing 0 5 Hz a Battery related Error b Low battery voltage v 20 Off No error Signal Strength Green ON normal 4 ON Full signal RSRP Index 56 85 dBm RSRP 3 ON Good signal RSSP Index 47 94 dBm RSRP 85 dBm 2 ON Okay signal RSRP Index 37 104 dBm RSRP 95 dBm 1 ON Poor signal RSRP Index 0 RSRP 105 dBm ALL OFF No signal Not registered to network or regist...

Отзывы: