background image

 

 

4. Input port mapping 

In order to get correct information, TIG 2go requires the input ports DI0 to DI3 be mapped to the fol-

lowing signals from the machine: 

4.1. 

Status information 

The first two wires are expected to be connected to a continuous signal for the machine and produc-

tion status. Each change of TRUE/FALSE in any direction is considered a status change and will be 

recorded. 

Input Port 

Meaning 

Explanation 

DI0 

ONLINE / OF-

FLINE 

Signals the “on” state of the connected device, e.g. a machine. A “True” 

signal is interpreted as ONLINE, “False” as OFFLINE. 

In order to provide useful information, the machine interface should not 

just signal its own “power on” status, but communicate whether or not 

the machine itself is up and “ready to go”. The informative value of this 

status information depends on the ability of the machine’s host com-

puter to determine and transmit a meaningful machine ONLINE / OF-

FLINE condition. 

DI1 

PRODUCING / 

NOT PRO-

DUCING 

Signals whether the device is running. 

A “True” signal is interpreted as PRODUCING. This status should be 

signaled whenever the production status of the machine is “Production”. 

A “False” signal is interpreted as NOT PRODUCING. 

As with the ON / OFF status, the informative value of the RUNNING / 

STOPPED status information depends on the ability of the machine’s 

host computer to properly determine and transmit the machine’s current 

production status. 

 

 

 

 

Содержание WISE-4050

Страница 1: ...Advantech WISE 4050 Installation Guide for TIG 2go Revision 1 4 ...

Страница 2: ... 3 Hardware setup 5 3 1 Step 1 Internet connection 5 3 1 1 Wi Fi 5 3 1 2 LAN 5 3 2 Step 2 Cloud connection 6 3 3 Step 3 Device configuration 6 3 4 Step 4 Device registration 7 4 Input port mapping 8 4 1 Status information 8 4 2 Counter information 9 4 2 1 Alternate signaling systems 9 4 2 2 Concurrent signaling systems 10 5 Revision index 11 ...

Страница 3: ...and qualified personnel In case of any queries re garding the machine interface please contact the machine manufacturer 1 1 Hardware variants Advantech provides two hardware variants WIFI and LAN version Advantech WISE 4050 Advantech WISE 4050 LAN For more information on the device please refer to the manual by the manufacturer which can be downloaded here 1 2 Reference WISE 4050 is a product of A...

Страница 4: ...nternet connection depending on local network Configure MQTT broker settings o MQTT Host Name mqtt cred tig2go com o Port Number 61614 o SSL secure Enable o User Name tig2gouser o Password abysm manager bump boulder Enable logging via push notifications for all channels Change of State Recalibrate Time 2 3 Connect Connect the device with the internet cable or Wi Fi 2 4 Register Register the device...

Страница 5: ...work Information click Go to Configuration and enter your Wi Fi connection infor mation 3 1 2 LAN Power up using a 10 30V power sup ply that s connected between the Vs and Vs pin Use an Ethernet cable to connect be tween the RJ 45 port and the Ethernet switch Set the IP address of your device to the same as your IP domain The default IP address of the WISE module is 10 0 0 1 For example set your P...

Страница 6: ...r Name tig2gouser o Password abysm manager bump boulder o Hearbeat Frequency sec 60 o Publish QoS 2 o Subscribe QoS 2 Submit and ensure that the Connection Status is Connected 3 3 Step 3 Device configuration Configure the device so that it sends the data to the MQTT broker Go to Advanced Data Logger In tab Data Configuration o In Log Data Channel Fields For all Input Channels 0 3 enable Change of ...

Страница 7: ...Admin email o Read Only email The login credentials for the ad min and read only user are sent to the respective email ad dresses The admin email will have more rights on the TIG2go platform Name of the connected machine The name will be used to identify the machine in the TIG2go platform Currently only alphanu meric characters are supported Configuration of the connected machine o Counter informa...

Страница 8: ...ion the machine interface should not just signal its own power on status but communicate whether or not the machine itself is up and ready to go The informative value of this status information depends on the ability of the machine s host com puter to determine and transmit a meaningful machine ONLINE OF FLINE condition DI1 PRODUCING NOT PRO DUCING Signals whether the device is running A True sign...

Страница 9: ...aling systems After every completion of a good cycle this information is signaled over one wire the good signal line whereas a bad cycle is signaled over the other wire the bad signal line Good and bad cycles will therefore result in raising a True signal in one of the two counter lines but never in both of them at the same time Input Port Meaning Explanation DI2 GOOD CY CLE Signals the completion...

Страница 10: ...n over the cy cle signal line Bad cycles will therefore result in raising a True signal in both counter signal input ports The TIG daas system will recognize and correctly handle these situations by counting such cy cles as bad Input Port Meaning Explanation DI2 CYCLE COM PLETED Signals the completion of a cycle On each True signal received the GOOD PARTS COUNTER is in cremented if and only if the...

Страница 11: ...e Revision Author Commentary 2018 Dec 18 1 0 VB Initial Version 2019 Jan 17 1 1 VB Corrected MQTT settings port 2019 Mar 20 1 2 VB Added quick start section 2019 Mar 28 1 3 PL Added Reference 2019 Apr 02 1 4 VB Adapted to CI ...

Отзывы: