UR5i v2
6.2
Start
The router is put into operation when the power supply is connected to this router. By
default, the router will automatically start to log on to the default APN. DHCP server will start
to assign addresses for devices on the Ethernet port ETH0. Router’s behavior can be changed
via the web interface. This is described in detail in the
Configuration manual for v2 routers
.
The power consumption during receiving is 2.6 W. The peak power consumption during
data sending is 5.5 W. However, values of consumption can be increased, if some expansion
port is equipped. For correct operation it is necessary that the power source is able to supply
a peak current of 1 A.
6.3
Configuration
If no SIM card is inserted in the router, it is not possible to operate. Inserted SIM card
must have activated data transmission.
6.3.1
Configuration over web browser
For status monitoring, configuration and administration of the router is available a web
interface which can be accessed by entering the IP address of the router into the web browser.
The default IP address of the router is 192.168.1.1.
Figure 32: Entering the IP address of the router
Configuration may be performed only by the user "root". The default password is printed
on the router’s label.
Change the default password as soon as possible!
Figure 33: Entering login information
1
If the router’s label does not contain a unique password, use the password "root".
27