UNO-3072A/3074A User Manual
20
2.5.7 Interrupt Triggering Edge Control
The interrupt can be triggered by a rising edge or a falling edge of the
interrupt signal, as determined by the value in the interrupt triggering edge
control bit in the interrupt control register, as shown in Table 2.15.
2.5.8 Interrupt Flag Bit
The interrupt flag bit is a flag indicating the status of an interrupt. It is a
readable/writable bit. To find the status of the interrupt, you have to read
the bit value. To clear the interrupt, you have to write “1” to this bit. This
bit must first be cleared to service the next coming interrupt.
Table 2.4: Interrupt Triggering Edge Control
DI0TE & DI1TE
Triggering edge of interrupt signal
0
Falling edge trigger
1
Rising edge trigger
Table 2.5: Interrupt Flag Bit Values
DI0F & DI1F
Interrupt Status
Read
0
No interrupt
1
Interrupt occur
Write
0
Don’t care
1
Clear interrupt
Note:
UNO-3072A/3074A provides built-in examples to show
how to deliver digital input functionality. Refer to console
mode examples in
C:\Program Files\Advantech\UNO\UNO_IsaDIO\Exam-
ples\Console.
(Please install DI/O driver from the UNO CD to use
these examples)
Содержание UNO-3072A
Страница 10: ...UNO 3072A 3074A User Manual x ...
Страница 16: ...UNO 3072A 3074AUser Manual 6 1 4 Chassis Dimensions Figure 1 1 Chassis Dimensions ...
Страница 18: ...UNO 3072A 3074AUser Manual 8 ...
Страница 50: ...UNO 3072A 3074A User Manual 40 ...
Страница 57: ...47 Chapter 3 6 Screw back the upper cover with the eight screws ...
Страница 63: ...APPENDIX A System Settings and Pin Assignments ...
Страница 80: ...UNO 3072A 3074A User Manual 70 ...
Страница 81: ...APPENDIX B Programming the Watchdog Timer ...
Страница 84: ...UNO 3072A 3074A User Manual 74 ...