7
TREK-60 User Manual
C
ha
pte
r 1
G
en
era
l In
fo
rm
atio
n
EMC:
–
Emissions: FCC Part 15 Subpart B Class A, IC ICES-003 Class A, EN 55032
Class A, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3
–
Immunity: EN 55035, EN 61000-6-2/EN 61000-6-4
Power Consumption
Note 1: The converter efficiency is 90 ~ 95%. Thus, if the PoE loader setting is 30W,
the input power must be at least 33W (for sufficient power at 90% efficiency).
Note 2: The system tested was a TREK-60 platform equipped with 32 GB UMLC
mSATA, u-Blox NEO-M8N, RF extension module with Wi-Fi and WWAN, SDP 2.0,
and a TREK-306PH2 display.
Note 3: Tested at an environmental temperature of 25 °C/77 °F.
Note 4: Burn-in setting test items: CPU, memory, 2D/3D GPU, video, and SSD.
Table 1.3: Power Consumption for Intel® Core™ i7-7600U CPU Model
Mode
PoE Loader
SDP2.0
Without SDP2.0
Power off
NA
0.096W
0.096W
Idle
0W
34.9W
19.7W
Burn-in
0W
63.6W
47.5W
30W
96.6W
80.5W
60W
129.6W
113.5W
Table 1.4: Power Consumption for Intel® Atom™ E3940 CPU Model
Mode
PoE Loader
SDP2.0
12/24V
Without SDP2.0
12/24V
Power off
NA
0.096W
0.096W
Idle
0W
34.1W/31.7W
16.7W/17.8W
Burn-in
0W
40.7W/37.7W
22.3W/23.5W
30W
73.7W/70.7W
55.3W/56.5W
60W
106.7W/103.7W
88.3W/89.5W
Содержание TREK-60
Страница 1: ...User Manual TREK 60 Modular AI Platform for Scalable Surveillance and Fleet Management ...
Страница 8: ...TREK 60 User Manual viii ...
Страница 10: ...TREK 60 User Manual x ...
Страница 11: ...Chapter 1 1 General Information ...
Страница 18: ...TREK 60 User Manual 8 1 5 Dimensions Figure 1 2 TREK 60 Dimensions ...
Страница 19: ...Chapter 2 2 System Setup ...
Страница 25: ...15 TREK 60 User Manual Chapter 2 System Setup ...