background image

SmartStart SL305

6.2

Start

The router will start when a power supply is connected to the router. By default, the router

will automatically start to log on to the default APN. The DHCP server will start to assign
addresses for devices connected through the Ethernet port ETH. Router’s behavior can be
changed via the web interface. This is described in detail in the

Configuration manual for

SmartStart

.

6.3

Configuration

If no SIM card is inserted in the router, it is not possible for the router to operate. Any
inserted SIM card must have active data transmission.

6.3.1

Configuration by web browser

For status monitoring, configuration and administration of the router, a web interface is

available, which can be accessed by entering the IP address of the router into the web browser.
The default IP address of the router is 192.168.1.1.

Attention, it is necessary to use HTTPS

protocol for secure communication over a network!

Figure 25: Entering the IP address of the router

By default, configuration may be performed only by the user "root". The default password is
printed on the router’s label.

1

Change the default password as soon as possible!

All routers have the

WebAccess/DMP

client pre-installed by default. The activated client

periodically uploads router identifiers, configuration, and cellular network statistics to the

WebAccess/DMP

server. See the configuration manual

[2]

chapter

Basic Information ->

WebAccess/DMP Configuration

, for more information.

1

If the router’s label does not contain a unique password, use the password "root".

25

Содержание SL305

Страница 1: ...LTE Industrial Router SmartStart SL305 USER MANUAL ...

Страница 2: ... subject to change without notice and does not represent a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication i...

Страница 3: ...pecific situations Information notice Useful tips or information of special interest GPL licence Source codes under GPL licence are available at https icr advantech cz source code address Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0056 EN revision from March 3 2022 Released in the Czech Republic ii ...

Страница 4: ...11 5 4 1 Front view 11 5 4 2 Top view 11 5 4 3 Bottom view 12 5 4 4 Rear view 12 5 5 Mounting recommendations 13 5 6 Removal from the DIN rail 14 5 7 Description of the Rear Panel 15 5 8 Description of the Front Panel 15 5 8 1 Status indication 16 5 8 2 Power PWR IO Connector 17 5 8 3 Antenna Connector ANT DIV and WiFi 19 5 8 4 SIM Card Reader 20 5 8 5 Ethernet Port ETH 21 5 8 6 Serial Port RS232 ...

Страница 5: ...on of user interfaces 29 7 3 Standards and Regulations 29 7 4 Type Tests and Environmental Conditions 30 7 5 Technical Parameters of Module 31 7 6 Technical Parameters of WiFi 32 7 7 Other Technical Parameters 32 8 Related Documents 33 9 Troubleshooting 34 9 1 FAQ 34 10 Customer Support 37 iv ...

Страница 6: ...Default position of metal DIN rail clip 14 13 Removal from the DIN rail 14 14 SmartStart front panel 15 15 PWR IO connector 17 16 Circuit example connection of power supply 17 17 Binary connection 18 18 Connecting the antenna 19 19 SIM cards 20 20 Ethernet connector 21 21 Connection of Ethernet cable 21 22 RS232 connector 22 23 Router reset 23 24 Router connection 24 25 Entering the IP address of ...

Страница 7: ...stics of binary input 18 8 Connection of Ethernet connector 21 9 Connection of RS232 connector 22 10 Description of router reset and restart 23 11 Basic parameters 28 12 Technical specification of user interfaces 29 13 Standards and regulations 29 14 Type tests and environmental conditions 30 15 Technical parameters of module for EMEA 31 16 Technical parameters of WiFi 32 17 Other technical parame...

Страница 8: ...router to extreme ambient conditions Protect the router against dust moisture and high temperature Only routers with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the utilization...

Страница 9: ...o minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains a battery Remove the battery from the device before disposal The battery in the device needs to be disposed of apart accordingly Check the terms and conditions ...

Страница 10: ... point in the future The SmartStart router is supplied in a plastic casing 3 3 Configuration and Diagnostics The router can be configured using a password protected Web interface The web interface provides after logging in detailed statistics about the router activities signal strength detailed system logs etc This device supports the creation of VPN tunnels using technologies IPSec OpenVPN and L2...

Страница 11: ...ccess Examples of possible applications mobile office smart meters for utilities fleet management security systems telematic telemetric remote monitoring vending and dispatcher machines 3 4 Usage of the Router The router is primarily intended for these four basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN 5 ...

Страница 12: ...SmartStart SL305 II Backed up access to the Internet from LAN Figure 2 Backed up access to the Internet III Secure networks interconnection or using VPN Figure 3 Using a VPN tunnel 6 ...

Страница 13: ...SmartStart SL305 IV Serial Gateway Figure 4 Serial Gateway 7 ...

Страница 14: ...ntents of Package The basic router set available for delivery includes the following items router power and IO cable 1 5 m long clip for the DIN rail two screws are included paper start guide Figure 5 Contents of package 8 ...

Страница 15: ...er is supplied in the following versions see table below All versions are available only in plastic casing Router versions SIM BIN BOUT ETH RS232 WiFi SL305 with RS232 2 x 1 x 1 x 1 x 1 x SL305 with RS232 WiFi 2 x 1 x 1 x 1 x 1 x 1 x Table 1 Router versions Figure 6 Front panel 9 ...

Страница 16: ...ion Figure 7 Product label 5 3 Order Codes The table below shows an overview of order codes Name Order code Features interfaces SmartStart SL305 BB SL30500110 LTE module Cat 4 EMEA 1x ETH 1x RS232 1x BI 1x BO 2x SIM reader SmartStart SL305 BB SL30510110 LTE module Cat 4 EMEA 1x ETH 1x RS232 1x BI 1x BO 2x SIM reader WiFi Table 3 Order codes overview 10 ...

Страница 17: ...SmartStart SL305 5 4 Basic Dimensions of the Router 5 4 1 Front view Figure 8 Front view 5 4 2 Top view Figure 9 Top view 11 ...

Страница 18: ...SmartStart SL305 5 4 3 Bottom view Figure 10 Bottom view 5 4 4 Rear view Figure 11 Rear view 12 ...

Страница 19: ...hese instructions For whip antennas it is recommended to observe a minimum distance of 6 cm from ca bles and metal surfaces on every side in order to avoid interference When using an external antenna separate from the switchboard it is necessary to fit a lightning conduc tor When mounting a router on sheet steel we recommend using a cable antenna For all cables we recommend to bind the bunch and f...

Страница 20: ... is shown in the following figure When mounting the DIN rail clip tighten the screws with max 0 4 Nm torque Figure 12 Default position of metal DIN rail clip To remove the router from the DIN rail push the router down lightly so the bottom part of the DIN rail clip hitched to the DIN rail gets out of the rail and then pull out the bottom part of the router away from the DIN rail Figure 13 Removal ...

Страница 21: ...8 7 5 8 Description of the Front Panel On the front panel is the following Caption Connector Description PWR IO 4 pin Connector for the power supply and connection of the binary input and output ETH RJ45 Connector for connection into the computer network RS232 DB9 female Connector for serial interface RS232 ANT SMA Connector for main antenna DIV SMA Connector for diversity antenna WiFi R SMA Conne...

Страница 22: ...ellow Fades out 1x 5 s Fades out 1x 2 s Fades out 1x 1 s Signal strength is good Signal strength is fair1 Signal strength is poor2 For value ranges of signal strength see Configuration manual chapter Mobile WAN Status ETH Green On Off Selected 100 Mbps Selected 10 Mbps ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected Table 5 Status indi...

Страница 23: ...r supply cable provided with device is not used always use the cables with minimum wire size nominal cross section 0 5 square mm for power supply The power supply for the router must be between 9 V to 36 V DC with current output 1 A Protection against reversed polarity without signaling is built into the router Note The protection against reversed polarity is lost if the negative pole is grounded ...

Страница 24: ...ut connections Binary inputs and output connections example Figure 17 Binary connection Low Power Mode The router can be put into low power mode using a special command lpm It can then be awakened by an activity on binary input or using an internal timer For more details of this command see the application note Commands and Scripts 3 Consumption in LPM mode may vary depending on the configuration ...

Страница 25: ...y antenna the second antenna connector DIV is used An R SMA connector named WiFi is designed for the connection of a WiFi antenna available only for versions with a WiFi module The router can not operate without a main antenna connected through the port marked as ANT An SMA connector is used for the connection of the antenna The antenna is connected by screwing this antenna to the SMA connector on...

Страница 26: ...oint Names adjusted Supported type of SIM cards mini SIM 2FF dimensions 25 0 x 15 0 x 0 76 mm Changing the SIM card Always disconnect the router from the power supply before handling the SIM card To remove the SIM card use the flat end of a spudger or your fingernail press the SIM card slightly into its slot until you hear a click After hearing this click release the card and it will pop out of it...

Страница 27: ...flow direction 1 TXD Transmit Data positive pole Input Output 2 TXD Transmit Data negative pole Input Output 3 RXD Receive Data positive pole Input Output 4 5 6 RXD Receive Data negative pole Input Output 7 8 Table 8 Connection of Ethernet connector Figure 20 Ethernet connector The Ethernet cable plugs into the RJ45 connector labeled as ETH see the figure below Figure 21 Connection of Ethernet cab...

Страница 28: ...iption Data flow direction 1 DCD Data Carrier Detect Output 2 RXD Receive Data Output 3 TXD Transmit Data Input 4 DTR Data Terminal Ready Input 5 GND System Ground 6 DSR Data Set Ready Output 7 RTS Request to Send Input 8 CTS Clear to Send Output 9 RI Ring Indicator NC Table 9 Connection of RS232 connector Figure 22 RS232 connector 22 ...

Страница 29: ...r small tool Figure 23 Router reset Before resetting the router it is recommend to back up the router configuration settings see Configuration manual because resetting the router will return all configuration set tings to their default states It is important to distinguish between a router reset and reboot Action Router behavior Invoking events Reboot Turns off and then turns on the router Disconn...

Страница 30: ...o operation it is necessary to connect all of the components that are required to run your applications Don t forget to insert a SIM card The router can not operate without a connected antenna SIM card and power supply If the antenna is not connected the router may be damaged Figure 24 Router connection 24 ...

Страница 31: ...r a web interface is available which can be accessed by entering the IP address of the router into the web browser The default IP address of the router is 192 168 1 1 Attention it is necessary to use HTTPS protocol for secure communication over a network Figure 25 Entering the IP address of the router By default configuration may be performed only by the user root The default password is printed o...

Страница 32: ...SmartStart SL305 Figure 26 Entering login information 26 ...

Страница 33: ...tered successfully the user will have access to the router s web interface via the web browser Figure 27 Router web interface A detailed description of the router settings in the Web interface can be found in the Configuration manual for SmartStart 27 ...

Страница 34: ...Degree of protection IP30 Supply voltage 9 to 36 V DC Battery for RTC CR1225 Consumption without WiFi Average Maximum 2 1 W 4 8 W Consumption with WiFi Average Maximum 2 7 W 5 5 W Sleep mode consumption 40 mW Dimensions 30 x 87 x 150 mm DIN 35 mm EN 60715 Weight approximately 187 g depends on interface Antenna connectors 2x SMA 50 Ohm 1x R SMA 50 Ohm only for WiFi Table 11 Basic parameters Tempera...

Страница 35: ... user interfaces 7 3 Standards and Regulations The router complies with the following standards and regulations Standards and regulations for EMEA routers National CE UKCA EMC EN 301 489 1 EN 301 489 17 EN 301 489 52 EN 61000 6 2 EN 55032 class B Radio EN 301 511 EN 301 908 1 EN 301 908 2 EN 301 908 13 EN 300 328 Safety EN 62368 1 Transportation E Mark E8 homologation number 10R 04 8634 Environmen...

Страница 36: ...N 61000 4 6 All ports AC DC 10 V crit A 0 15 80 MHz 10 V crit A Voltage dips interrup tions EN 61000 4 11 AC DC Dry heat EN 60068 2 2 Operation Storage 75 C 40 rel humidity 16 hours 85 C 40 rel humidity 16 hours Cold EN 60068 2 1 Operation Storage 40 C 16 hours 40 C 16 hours Damp heat EN 60068 2 30 test Db 55 C 25 C 6 h 6 h 2 cycles Temperature variation EN 60068 2 14 Nb 40 C 75 C 3 h 3 h 2 cycles...

Страница 37: ...encies B8 900 MHz B1 2100 MHz Max power typical 24 dBm UMTS parameters PS bit rate 384 kbps DL 384 kbps UL Supported frequencies B8 900 MHz B1 2100 MHz Max power typical 24 dBm GPRS EDGE parameters Bit rate 296 kbps DL 236 kbps UL Supported frequencies 900 1800 MHz Other parameters Rx Diversity and MIMO DL 2x2 Table 15 Technical parameters of module for EMEA Antenna Requirements VSWR 2 1 Antenna i...

Страница 38: ...n 18 typ 19 max 20 dBm 11g 54 Mbps min 14 5 typ 16 max 17 5 dBm 802 11n HT20 min 13 5 typ 15 max 16 5 dBm 802 11n HT40 min 13 5 typ 15 max 16 5 dBm Type of device Access point station AP maximum users Unlimited WiFi module does not support multi role oper ation Table 16 Technical parameters of WiFi 7 7 Other Technical Parameters Other technical parameters CPU power 2 DMIPS per MHz Flash memory Ava...

Страница 39: ...SmartStart SL305 8 Related Documents 1 Advantech Czech Start Guide for SmartStart 2 Advantech Czech SmartStart Configuration Manual 3 Advantech Czech Commands and Scripts 33 ...

Страница 40: ... status page If the signal power is weak you will have to use a better antenna If the neighbouring cells have a similar signal strength you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable automatic ping from the router which will check the connection when there are no data running and in the case of a failed ping restart the connection Th...

Страница 41: ... You can verify NAT using ping to your server with static address and then compare with router s IP address You can verify a Firewall by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the System Log DynDNS daemon sta...

Страница 42: ...routers only You can use SFTP on all routers to transfer files to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can c...

Страница 43: ...eu Web www advantech com Customer Support for NAM Advantech B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 1 815 433 5109 E mail support advantech bb com Web www advantech bb com Customer Support for Asia Phone 886 2 2792 7818 1299 Monday Friday 9 a m to 5 30 p m UTC 8 Fax 886 2 2794 7327 E mail icg support advantech com tw Web www ad...

Страница 44: ...complies with Radio Equipment Regulations 2017 S I 2017 No 1206 We Advantech Czech s r o declare that the radio equipment narrated in this user s manual complies with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following internet address icr advantech cz eudoc ...