background image

RS-100-SF User’s Manual 

4

1.

 

Collect all the information about the problem encountered. 

For example, CPU speed, Advantech products used, other 

hardware and software used, etc. Note anything abnormal 

and list any on-screen messages you get when the 

problem occurs. 

 

2.

 

Call your dealer and describe the problem. Please have 

your manual, product, and any helpful information 

readily available. 

 

3.

 

If your product is diagnosed as defective, obtain an RMA 

(return merchandise authorization) number from your 

dealer. This allows us to process your return more 

quickly. 

 

4.

 

Carefully pack the defective product, a fully completed 

Repair and Replacement Order Card and a photocopy 

proof of purchase date (such as your sales receipt) in a 

shippable container. A product returned without proof of 

the purchase date is not eligible for warranty service. 

 

5.

 

Write the RMA number visibly on the outside of the 

package and ship it prepaid to your dealer. 

 

Содержание RS-100-SF

Страница 1: ...User s Manual RS 100 SF 1U Server ...

Страница 2: ...ny form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties that may result from its use CE Notification RS 100 SF developed by Advantech Co Ltd has passed the CE ...

Страница 3: ...tion z Intel Pentium 4 is trademarks of Intel Corporation z Windows 98 ME 2000 XP are trademarks of Microsoft Corporation z SiS is a registered trademark of Silicon Integrated Systems Corp z ITE is a trademark of ITE Corp All other product names or trademarks are properties of their respective owners Part No 2002010090 1st Edition Printed in Taiwan July 2002 ...

Страница 4: ...e accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repai...

Страница 5: ...tion readily available 3 If your product is diagnosed as defective obtain an RMA return merchandise authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without pr...

Страница 6: ...ews z 1 CD Title Driver Bank z 1 Power cord z RS 100 SF User s Manual in Driver Bank CD z 1 Warrant Card Technical Support and Sales Assistance If you have any technical questions about the RS 100 SF series products please visit our support website at http www advantech com tw support For more information about Advantech products and sales information please visit http www advantech com ...

Страница 7: ...d Layout 17 2 3 I O Ports 18 2 4 Jumpers and Connectors on motherboard 19 2 5 Safety Precautions 21 2 6 System Installation 22 2 6 1 Installing Memory 22 2 6 2 Memory Installation Procedure 22 2 6 3 Cache Memory 25 2 6 4 CPU Installation 26 2 6 5 Installing HDD Drive 30 2 6 6 Installing Add on Card 33 Chapter 3 BIOS Setup 35 3 1 Function Keys 36 3 2 Main Menu 37 3 2 1 Standard CMOS Features 38 3 2...

Страница 8: ...out Saving 70 Chapter 4 Driver Installation 73 4 1 Install VGA Driver 73 4 1 1 Driver Installation for Win98 ME 73 4 1 2 Driver Installation for Win2K XP 74 4 1 3 Driver Installation for Linux 74 4 1 4 Driver Installation for FreeBSD 4 x 74 4 1 5 Driver Installation for QNX R6 1 75 4 2 Install LAN Driver 76 4 2 1 Driver Installation for Win98 ME 76 4 2 2 Driver Installation for Win2K XP 78 4 2 3 D...

Страница 9: ...RS 100 SF User s Manual 8 Appendix A Memory Approval List 80 Appendix B Safety Instructions 81 B 1 English 81 B 2 German Wichtige Sicherheishinweise 83 ...

Страница 10: ...Acceleration MPEGI MPEGII Video Decoder for the Intel Pentium 4 series based PC systems It also integrates a high performance 3GB s DDR266 Memory controller to sustain the bandwidth demand from the integrated GUI or external AGP master host processor as well as the multi I O masters In addition to the integrated GUI the SiS650 can also support external AGP slot with AGP 4X capability and Fast Writ...

Страница 11: ...and advanced hardware acceleration logic to deliver high quality DVD playback The RS 100 SF has one PCI slots for function expansion The SIS650 currently supports front bus PSB processor at 400MHz The RS 100 SF will support PSB 533MHz once it upgrades to the SIS651 chipset ...

Страница 12: ... Socket DDR 266 DIMM x 3 Controller Integrated in SIS 650 with AGP 4X Graphic VRAM Shares with system memory up to 4 8 16 32 64MB Interface 10 100 Base TX Controller Intel 82559ER x2 Ethernet Connector RJ 45 x2 Expansion PCI 1 PCI bus slot 3 5 HDD 2 IDE HDD space 3 5 FDD 1 Drive Bay 24 X speed CD ROM 1 I O Interface USB 2 Serial 2 RS 232 PS 2 2 mouse x1 keyboard x1 CRT 1 Cooling Fan 75 CFM system ...

Страница 13: ...nd HDD Miscellaneous Control Momentary power switch Watt 200W ATX Power Supply Input AC 90 264 V Full Range 47 63 Hz Operating Non Operating Temperature 0 40 C 32 104 F 20 70 C 68 158 F Environment Humidity 5 85 40 C 104 F 5 95 Physical Dimension W x H x D 482 x 44 2 x 502 mm 19 x 1 73 x 19 76 Weight 6 kg ...

Страница 14: ...RS 100 SF User s Manual 13 1 2 Software Specifications OS support Windows XP 2000 98 ME RedHat Linux 6 x 7 x FreeBSD 4 x No support for Win NT Series ...

Страница 15: ...RS 100 SF User s Manual 14 1 3 Environmental Specifications Operating temperature 0 50 C Storage temperature 40 75 C 40 167 F Operating Humidity 10 85 40 Storage Humidity 5 95 ...

Страница 16: ... User s Manual 15 Chapter 2 Placement and Installation 2 1 System Placement 2 1 1 Frontal View CD ROM drive FDD drive Power switch LED 2 1 2 Rear View Power switch PS 2 VGA LAN Power socket USB RS 232 Expansion ...

Страница 17: ...RS 100 SF User s Manual 16 2 1 3 Top View HDD location CD ROM FDD Power Supply FAN Motherboard ...

Страница 18: ... 2 2 Board Layout ATX Power connector JP35 DDR DIMM IDE 2 Connector JP15 JP12 IDE 1 Connector JP9 JP8 FDD Connector Parallel Connector JP5 S1 U1 Connector JP7 CPU socket ATXPWR1 APG 4X slot PCI slot ISA Slot JP2 CNR slot J6 JP34 ...

Страница 19: ...RS 100 SF User s Manual 18 2 3 I O Ports PS 2 KB port USB port VGA port COM1 Port LAN1 LAN2 PS 2 Mouse Port COM2 port ...

Страница 20: ...2 LED 7 Signal 8 VCC5 9 10 IDE Channel 0 LED 9 Signal 10 VCC5 11 12 IDE Channel 1 LED 11 Signal 12 VCC5 J5 POWER LED Pin Function Remark 1 3 POWER LED 1 Vcc3 2 3 GND JP5 SUPER I O BATTERY SUPPLY Pin Function Remark 1 2 POWER FROM BATTERY 2 3 POWER FROM SB3V Close Default 2 3 close S1 Flash ROM Size Pin Function Remark 1 2 ROM Size is 2Mbit Close 2 3 ROM Size is 4Mbit Default 1 2 close ...

Страница 21: ...Remark 1 2 CMOS Clear 2 3 RTC COMS Active Close Default 2 3 close JP38 SPEAKER SELECT Jumper Function Remark 1 2 Internal BUZZER Close 2 3 External SPEAKER Fan Connectors JP2 JP7 JP9 JP12 JP15 JP34 JP35 Pin Function 1 Ground 2 12V 3 TACK Sensor JP 35 is used for CPU fan ...

Страница 22: ...amaged by sudden power surges Only experienced electronics personnel should open the PC chassis Caution Always remember to ground yourself when removing any static charge before touching the CPU card Modern electronic devices are very sensitive to static electric charges As a safety precaution use a grounding wrist strap at all times Place all electronic components in a static dissipative surface ...

Страница 23: ...3 GB of memory 2 6 2 Memory Installation Procedures To install DDR DIMMs first make sure the two handles of the DDR DIMM socket are in the open position i e The handles lean outward Slowly slide the DDR DIMM module along the plastic guides on both ends of the socket Then press the DDR DIMM module right down into the socket until you hear a click This is when the two handles have automatically lock...

Страница 24: ...RS 100 SF User s Manual 23 DDR DIMM 184 pin Press the socket retaining latches back out of the way ...

Страница 25: ... socket place it in the socket so that the edge connectors insert slightly in the socket Make sure they match Press the DDR DIMM into the socket so that it seats firmly in place and the retaining latches rotate upwards and seat them selves in the notches on the side of the DDR DIMM Repeat this operation for the rest of DIMMs you will install ...

Страница 26: ...r you do not have to take care of either SRAM chips or SRAM modules The built in second level cache in the Pentium 4 Celeron processor yields much higher performance than the external cache memories The cache size in the Intel Pentium 4 processor is 512KB depending on the type of CPU The cache size in the Intel Celeron processor is 128KB ...

Страница 27: ...Intel Pentium 4 Celeron Processor The CPU on the board must have a fan or heat sink attached to prevent overheating Warning Without a fan or heat sink the CPU will overheat and cause damage to both the CPU and the motherboard To install a CPU first turn off your system Locate the processor socket 478 ...

Страница 28: ...he empty socket Follow the instructions that came with the CPU If you have no instructions complete the following procedure Carefully align the CPU so it is parallel to the socket and the notches on the corners of the CPU correspond with the notches on the inside of the socket Gently slide the CPU in It should insert easily If it does not insert easily pull the lever up a little bit more ...

Страница 29: ...ocket This is normal and will not damage the CPU When the CPU is installed the lever should snap into place at the side of the socket Note To remove a CPU pull the lever out to the side a little and raise it as far as it will go Lift out the CPU Paint the heat spread glue on the CPU evenly It is recommended but some CPU cooler fan comes with a thermal pad ...

Страница 30: ... s Manual 29 Place CPU cooler fan to sit on the top of the installed CPU then fasten the cooler fan on the motherboard with screw Please connect the fan power cable to JP35 the 3 pin fan power connector on the board ...

Страница 31: ...RS 100 SF User s Manual 30 2 6 5 Installing HDD Drive Unscrew the HDD tray Unlatch the HDD tray ...

Страница 32: ...RS 100 SF User s Manual 31 Put HDD drive into the HDD tray Fasten the HDD drive in the HDD tray with screws ...

Страница 33: ...RS 100 SF User s Manual 32 Place the HDD tray with HDD installed into chassis Fasten it with screw Plug HDD flat cable and power cable into HDD socket and power socket of the HDD drive respectively ...

Страница 34: ...Installing Add on Card Take off the riser card from the chassis plug the half size PCI add on card into the riser card then place it into Bracket and screw it Plug the riser with half size PCI add on card installed into PCI slot 1 3 2 ...

Страница 35: ...RS 100 SF User s Manual 34 Fasten the I O bracket of Add on card with screw Fasten the bracket of Add on card on the chassis with screw ...

Страница 36: ...hat it retains the Setup information when the power is turned off You should be able to use the BIOS optimized default settings as they come from the factory If you want to check or alter BIOS settings run the CMOS Setup Utility by pressing the Del key command during the POST If you think the settings need to be refreshed run the Setup Utility choose the Load Optimized Defaults option from the mai...

Страница 37: ... Select the menu item to the left or the right Enter Select menu item F10 Save Exit Setup The Function keys of sub menu are described as below Key Function Description Esc Jump to Exit menu or return to the main menu from sub menu or Move the cursor to the up or down between fields or Select the menu item to the left or the right PU PD Modify the value or setting Modify the value or setting Enter ...

Страница 38: ...ce you will setup and press Enter for selection When BIOS CMOS setup has been completed data in the CMOS RAM is automatically backed up to the Flash ROM This is particularly useful in industrial environments that may cause soft errors Upon such an error occurring BIOS will check the data and automatically restore the original data for booting ...

Страница 39: ...atures allows users to configure system components such as date time hard disk drive and floppy drive types showed in the screen below Date mm dd yy Set the system date The format is month day and year Move to proper place by arrow keys in order to modify the values by Page Up Key or Page Down Key Time hh mm ss change internal clock ...

Страница 40: ... 39 IDE Primary Master Move the highlight to the IDE Primary Master and enter to get the following screen IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD IDE Primary Master Auto Manual None ...

Страница 41: ... To auto detect the capacity cylinder head and sector of HDD IDE Primary Slave Auto Manual None Access Mode Auto Large LBA CHS IDE Secondary Master Choose the option then get the following three items IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD IDE Secondary Master Auto Manual None Access Mode Auto Large LBA CHS ...

Страница 42: ...41 IDE Secondary Slave Choose the option then get the following three items IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD IDE Secondary Slave Auto Manual None Access Mode Auto Large LBA CHS ...

Страница 43: ...SF User s Manual 42 Drive A Set the type of floppy drive installed by Page Up Key and Page Down Key Halt On Set system halt on when specified item occurs The selection items are showed in the following screen ...

Страница 44: ...k boot sector protection If this function is enabled and someone attempt to write data into this area BIOS will show a warning message on screen and alarm beep CPU L1 L2 Cache Enabled Disabled CPU L2 Cache ECC checking Enabled Disabled Quick Power On Self Test POST Enabled Disabled Allows the system to skip certain tests while booting This will decrease the time needed to boot the system ...

Страница 45: ...oot Other Device Enabled Disabled Select your boot device priority Swap Floppy Drive Enabled Disabled If the system has two floppy drives choose physical drive B to logical drive A and vice versa Boot Up Floppy Seek Enabled Disabled Enable During POST BIOS will determine if the floppy disk drive installed is 40 or 80 tracks A 360 KB type drive is 40 tracks while 720 KB 1 2 MB and 1 44 MB type driv...

Страница 46: ...tic delay can be selected Typematic Rate Chars Sec BIOS accepts the following input values characters second for typematic rate 6 8 10 12 15 20 24 and 30 Typematic Delay msec Typematic delay is the time interval between the appearances of two consecutive characters when holding down a key The input values for this category are 250 500 750 1000 msec Security Option System Setup The setting determin...

Страница 47: ...led This allows you to activate the SMART Self Monitoring Analysis Reporting Technology capability for the hard disks SMART is a utility that monitors your disk status to predict hard disk failure This gives you an opportunity to move data from a hard disk that is going to fail to a safe place before the hard disk becomes offline Video BIOS Shadow Enabled Disabled Enable copies video BIOS to shado...

Страница 48: ...nu Advanced DRAM Control 1 Move the highlight to the Advanced DRAM Control 1 and enter to get the following screen DRAM Timing Control By SPD Manual Set By SPD to enable DRAM Timing Control automatically to be determined by BIOS based on the configurations on the SPD Series Presence Detect EEPROM on the DRAM module ...

Страница 49: ... User s Manual 48 3 2 4 Integrated Peripherals Choose the Integrated Peripherals option from main menu SIS OnChip IDE Device Move the highlight to the SIS OnChip IDE Device and enter to get the following screen ...

Страница 50: ...onboard on chipset PCI IDE controller that supports Dual Channel IDE A maximum of 4 IDE devices can be supported If user installed the Off Board PCI IDE controller the user must choose which channels to disable This will depend on the channel used in the PCI Off Board add on card Normally select Both ...

Страница 51: ... 1 4 Each channel has both a master and a slave making four IDE devices possible Because each IDE device may have a different timing mode 0 1 2 3 4 it is necessary for these to be independent The default setting Auto will allow auto detection to ensure optimal performance ...

Страница 52: ...nd Secondary has a master and a slave making four IDE devices possible Because each IDE device may have a different timing mode 0 1 2 3 4 it is necessary for these to be independent The default setting Auto will allow auto detection to ensure optimal performance IDE Burst Mode Enabled Disabled ...

Страница 53: ...RS 100 SF User s Manual 52 On Chip Secondary PCI IDE Enabled Disabled IDE Secondary Master Slave PIO Auto Mode0 Mode 1 4 IDE Secondary Master Slave UDMA Auto Disabled ...

Страница 54: ...7012 AC97 AUDIO Disabled Enabled Default is set Disabled SIS 7013 S W Modem Disabled Enabled Please set Enable when system installs CNR Modem System Shares Memory Size 4 8 16 32 64MB The memory size you choose will be used by internal VGA as Video memory ...

Страница 55: ...o use the onboard FDD controller for accessing the FDD Otherwise please select Disabled to use the off board FDD controller Onboard Serial Port 1 Auto Disable 3F8 IRQ4 2F8 IRQ3 Onboard Serial Port 2 Auto Disable 3F8 IRQ4 2F8 IRQ3 The system has an onboard Super I O chipset with 2 serial ports The onboard serial ports can be selected as Auto Disable 3F8 IRQ4 COM 1 uses IRQ4 2F8 IRQ3 COM 2 uses IRQ3...

Страница 56: ...l ports as long as there are no conflicts for each port Parallel Port Mode ECP EPP This field allows you to set the operation mode of the parallel port The SPP setting allows normal speed operation but in one direction only EPP allows bi directional parallel port operation at maximum speed ECP allows the parallel port to operate in bi directional mode and at a speed faster than the maximum data tr...

Страница 57: ...oard Support Enabled Disabled Choosing Enabled will allow the system to use USB keyboard without device driver IDE HDD Block Mode Enabled Disabled Enabled allows the Block mode access for the IDE HDD Init Display First PCI slot AGP AGPAuto Calibration Disabled Enabled ...

Страница 58: ...RS 100 SF User s Manual 57 3 2 5 Power Management Setup Choose the Power Management Setup option from the main menu ACPI function Enabled Disabled ACPI Suspend Type ...

Страница 59: ...RS 100 SF User s Manual 58 Power Management Suspend Mode Video Off Option ...

Страница 60: ...RS 100 SF User s Manual 59 Video Off Method Switch Function MODEM Use IRQ ...

Страница 61: ...RS 100 SF User s Manual 60 HDD Off After Power Button Override Power State Resume Control ...

Страница 62: ...RS 100 SF User s Manual 61 PM Wake Up Events ...

Страница 63: ...configuration has caused a conflict for the OS to not boot select Enabled to reset Extended System Configuration Data ESCD when you exit Setup Resources Controlled by Auto Manual BIOS can automatically configure all the boot and plug play compatible devices If you choose Auto you cannot select IRQ DMA and memory base address fields since BIOS automatically assigns them ...

Страница 64: ...n the type of device using the interrupt IRQ 3 4 5 7 9 10 11 12 14 15 can be assigned PCI ISA PnP or Legacy ISA When resources are controlled manually assign a type to each system DMA channel depending on the type of device that is using the DMA channel DMA 0 1 3 5 6 7 can be assigned to PCI ISA PnP or Legacy ISA ...

Страница 65: ...isplay cards that are nonstandard VGA such as graphics accelerators or MPEG Video Cards may not show the proper colors The Enabled setting should correct this problem Otherwise leave this on the setup default setting of Disabled Recommend set Disabled ISA IO Memory Control ...

Страница 66: ...RS 100 SF User s Manual 65 3 2 7 PC Health Status The system can monitor system voltage CPU voltage CPU temperature system temperature CPU fan speed and system fan speed ...

Страница 67: ...t CPU clock ratio Normally please set Default Auto Detect DIMM PCI Clk Enabled Disabled CPU DRAM Clock Ratio This setting controls the CPU FSB Clock DRAM ratio frequency to enable the CPU DRAM and run under different frequency combinations Please note that the setting options vary according to the CPU FSB Clock preset ...

Страница 68: ...ts The option allows you to load the optimized default values for each of the parameters on the Setup menus When this option is pressed a confirmation is requested Select Y to load the optimized default values Select N or press Esc to discard the selection ...

Страница 69: ...ss Enter Type password and press Enter You can type up to eight alphanumeric characters If the CMOS is good or if this option has been used to change the default password the user is asked for the password stored in the CMOS The screen will display the following message Confirm Password Input the current password and press Enter ...

Страница 70: ...se the save option to save the values you selected to CMOS RAM The CMOS RAM is sustained by an onboard backup battery and stays on even when the system is turned off Once the option is selected a confirmation will be asked Select Y to save changes and exit ...

Страница 71: ...ng The option should only be used if you do not want to save the changes you have made to the Setup program If you have made changes to the fields the system will ask for confirmation before exiting Select Y then the system will keep the previous values ...

Страница 72: ...crosoft Windows 98 ME 2000 XP Linux 7 x Free BSD 4 x and QNX R6 1 In the driver bank CD disc there are some options as pictured below when running Setup or CD auto run The motherboard is used for SMB 2501 RS 100 SF and RS 400 SF After clicking the icon SMB 2501 or RS100 400 SF the following screen will be displayed ...

Страница 73: ...RS 100 SF User s Manual 72 There are four selections on the screen above 1 Install VGA driver 2 Install LAN driver 3 Install PCI to ISA Bridge driver 4 Manual ...

Страница 74: ...n Win98 ME folder 4 1 1 2 Excute setup exe 4 1 1 3 During the installation there will be three setups you can choose from Typical Install all of the components from this package including VGA driver and utilities Compact Install driver only Custom Install components of your choice It is recommended to choose Typical 4 1 1 4 Restart your computer when the installation is complete ...

Страница 75: ...ities Compact Install driver only Custom Install components of your choice It is recommended to choose Typical 4 1 2 4 Restart your computer when the installation is complete 4 1 3 Driver Installation for Linux Linux RedHat 7 x system can correctly recognize SiS 650 compatible VGA controller SiS 300 It is not necessary for user to load or modify the VGA driver for the onboard VGA device 4 1 4 Driv...

Страница 76: ...r the system supports text mode only 4 1 5 Driver Installation for QNX R6 1 QNX R6 1 system cannot correctly recognize SiS 650 compatible VGA controller but Standard VGA driver It is not necessary to load or modify the VGA driver for the onboard VGA device ...

Страница 77: ...ct the Device Manager tab Select View devices by type and navigate to Computer Other devices Highlight PCI Ethernet Controller and click on Properties 4 2 1 4 In the PCI Ethernet Controller Properties window select the Driver tab Then click on Update Driver 4 2 1 5 In the Update Device Driver Wizard window click on Next 4 2 1 6 In the Update Device Driver Wizard window select Search for a better d...

Страница 78: ...ubstituted as your CD ROM drive and click Next 4 2 1 9 Click Next to accept the updated driver for Intel R GD82559ER Fast Ethernet Adapter Click Next to continue with LAN driver installation 4 2 1 10 Follow the instructions on the screen Click Finish to complete installation 4 2 1 11 Restart the computer to finish LAN driver setup ...

Страница 79: ... 2 4 From the Properties dialog box click the Driver tab and click the Update Driver button The Update Device Driver Wizard appears Click Next 4 2 2 5 In the Update Device Driver Wizard window select Display a list of the known drivers for this device 4 2 2 6 Click Hard have Click Specify a location and click Browse button Then navigate to F 82559er where F should be substituted as your CD ROM dri...

Страница 80: ... the onboard LAN device However the LAN driver for Linux also be put on driver bank CD 4 2 4 Driver Installation for FreeBSD 4 x FreeBSD 4 x system can correctly recognize Intel 82559ER Fast Ethernet controller It is not necessary to load or modify the network driver for the onboard LAN device 4 2 5 Driver Installation for QNX R6 1 QNX R6 1 system can correctly recognize Intel 82559ER Fast Etherne...

Страница 81: ...ndor Capacity SAMSUNG K4H560838D TXB0 APACER 512 MB SAMSUNG K4H280838D TCB3 APACER 256 MB SAMSUNG K4H280838D TXB0 APACER 256 MB SAMSUNG K4H280838D TCB3 APACER 128 MB SAMSUNG K4H5600838D TCB3 Transcend 512 MB SAMSUNG K4H5600838D TCB3 Transcend 256 MB SAMSUNG K4H280838D TXB0 ATP 256 MB ...

Страница 82: ...l could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be...

Страница 83: ...llation reference guide e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 4 OR ABOVE 60 140 THE MAY DAMAGE THE EQUIPMENT The sound pressure level at the operator s position according to IEC 704 1 1982 is equal to or less than 70dB A DISCLAIMER This set of...

Страница 84: ...er Fallen Könnte Verletzungen hervorrufen 7 Die Belüftungsöffnungen dienen zur Luftzirkulation die das Gerät vor ü berhitzung schützt Sorgen Sie dafür daβ diese Öffnungen nicht abgedeckt werden 8 Beachten Sie beim Anschluβ an das Stromnetz die Anschluβwerte 9 Verlegen Sie die Netzanschluβleitung so daβ niemand darüber fallen kann Es sollte auch nichts auf der Leitung abgestellt werden 10 Alle Hinw...

Страница 85: ...gesetzt d Wenn das Gerät nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Gerät ist gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 15 Bitte lassen Sie das Gerät nicht unbehehrt hinten unter 20 4 oder oben 60 140 weil diesen Temperaturen das Gerät zerstören könten ...

Отзывы: