49
PCM-9562 User Manual
Chapter 4
S
oftware
Introduction
&
Installation
SMBus
When the application has executed, you can click the radio button to choose to test
each access mode, i.e. Access a byte, Access multiple bytes and Access a word. All
data must be read or written in hexadecimal except the numbers for radio button:
Access multiple bytes mode must be written in decimal. You can test the functional-
ities of the watchdog as follows:
Read a byte
–
Click the radio button- Access a byte.
–
Key in the slave device address in the Slave address field.
–
Key in the register offset in the Register Offset field.
–
Click the READ SMBus DATA button and a byte of data from the device will
be shown on the Result field.
Write a byte
–
Click the radio button- Access a byte.
–
Key in the slave device address in Slave address field.
–
Key in the register offset in Register Offset field.
–
Key the desired data in the Result field to write to the device.
–
Click the WRITE SMBus DATA button and then the data will be written to the
device through SMBus.
Read a word
–
Click the radio button- Access a word.
–
Key in the slave device address in the Slave address field.
–
Key in the register offset in the Register Offset field.
–
Click the READ SMBus DATA button and then a word of data from the device
will be shown on the Result field.
Write a word
–
Click the radio button- Access a word.
–
Key in the slave device address in the Slave address field.
–
Key in the register offset in the Register Offset field.
–
Key in the desired data, such as 0x1234, in the Result field to write to the
device.
–
Click the WRITE SMBus DATA button and the data will be written to the
device through the SMBus.