14
PCL-849 User's Manual
Default Settings
Mode
Enhanced
Mode
Port 1
IRQ12
Address 300H
Port 2
IRQ12
Address 308H
Port 3
IRQ12
Address 310H
Port 4
IRQ12
Address 318H
The following example shows how to set the base address to 2F8.
The switch sum is set to 2F8: 200 + 80 + 40 + 20 + 10 + 8 (HEX).
Note: On the PCL-849 address line A9 does not appear on the DIP
switch, as it is permanently hardwired to hex 200.
Interrupt Level (IRQ) Setting
(S1, JP1, JP2, JP3, JP4)
The card's IRQ can be set up using S1. Please note that the DIP
switch is for setting the mode as shown below.