8
PCL-734 User's Manual
We set the PCL-734 for a base address of Hex 300 at the factory. If
you need to adjust it to some other address range, set switch SW1 as
shown in the following table:
Card I/O addresses (SW1)
Range (hex)
Switch position
1
2
3
4
5
6
7
8
200 - 203
¡
l
l
l
l
l
l
l
204 - 207
¡
l
l
l
l
l
l
¡
⑨
* 300 - 303
¡
¡
l
l
l
l
l
l
⑨
3F0 - 3F3
¡
¡
¡
¡
¡
¡
l
l
¡
= Off
l
= On
* = default
Note:
Switches 1-8 control the PC bus address lines as shown
below:
Switch
1
2
3
4
5
6
7
8
Line
A9
A8
A7
A6
A5
A4
A3
A2
Appendix A provides a PC I/O port address map to help you avoid the
I/O addresses for standard PC devices.