background image

PCIE-1765 User Manual

iv

Safety Instructions

1.

Read these safety instructions carefully.

2.

Retain this user manual for future reference.

3.

Disconnect the equipment from all AC outlets before cleaning. Use only a damp 
cloth for cleaning. Do not use liquid or spray detergents.

4.

For pluggable equipment, the power outlet socket must be located near the 
equipment and easily accessible.

5.

Protect the equipment from humidity.

6.

Place the equipment on a reliable surface during installation. Dropping or letting 
the equipment fall may cause damage.

7.

The openings of the enclosure are for air convection. Protect the equipment 
from overheating. Do not cover the openings.

8.

Ensure that the voltage of the power source is correct before connecting the 
equipment to a power outlet.

9.

Position the power cord away from high-traffic areas. Do not place anything over 
the power cord.

10.

All cautions and warnings on the equipment should be noted.

11.

If the equipment is unused for a long time, disconnect it from the power source 
to avoid damage from transient overvoltage.

12.

Never pour liquid into an opening. This may cause fire or electrical shock.

13.

Never open the equipment. For safety reasons, the equipment should be 
opened only by qualified service personnel.

14.

If one of the following occurs, have the equipment checked by service person-
nel:

The power cord or plug is damaged.

Liquid has penetrated the equipment.

The equipment has been exposed to moisture.

The equipment is malfunctioning or does not operate according to the user 
manual.

The equipment has been dropped and damaged.

The equipment shows obvious signs of breakage.

15.

Do not leave this equipment in an environment where the storage temperature 
fluctuates below -20 °C (-4 °F) or above 60 °C (140 °F) as this may cause dam-
age. The equipment should be stored in a controlled environment.

16.

Batteries are at risk of exploding if incorrectly replaced. Replace only with the 
same or equivalent types as recommended by the manufacturer. Discard used 
batteries according to the manufacturer’s instructions.

17.

In accordance with the IEC 704-1:1982 standards, the sound pressure level at 
the operator’s position does not exceed 70 dB (A).

These instructions are provided according to IEC 704-1. Advantech disclaims all
responsibility for the accuracy of any statements contained herein.

Содержание PCIE-1765

Страница 1: ...User Manual PCIE 1765 12 Channel Relay PCI Express Card ...

Страница 2: ...umes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced free of charge during the warranty period For out of warranty repairs customers will be billed according to the cost of r...

Страница 3: ...name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages Warnings Cautions and Notes Document Feedback To assist us in making improvements to this manual we welcome all comments and constructive criticism Please send all such feedback...

Страница 4: ...2 Never pour liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following occurs have the equipment checked by service person nel The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed to moisture The equipment ...

Страница 5: ...2 1 Card connector jumper and switch locations 6 Table 2 1 Summary of Jumper Settings 6 Table 2 2 Board ID Settings SW1 7 2 3 I O Connectors 8 Figure 2 2 I O connector pin assignments 8 2 4 Device Setup and Configuration 9 Chapter 3 Signal Connections 11 3 1 Overview 12 3 2 Relay Connections 12 Figure 3 1 Relay output connection 12 Appendix A Specifications 13 A 1 Relay Output 14 A 2 General Speci...

Страница 6: ...PCIE 1765 User Manual vi ...

Страница 7: ...Chapter 1 1 Overview ...

Страница 8: ...off the system power the PCIE 1765 card can either retain the output values of each channel or return to its default open configuration depending on its onboard jumper settings This function protects the system from malfunctioning during unexpected system resets Plug and Play Functionality The PCIE 1765 card is a plug and play device that fully complies with PCIE Specifi cations Rev 2 0 During car...

Страница 9: ...LL driver Download from the product page LabVIEW driver Advantech DAQNavi Advantech s application software such as Advantech DLL Driver can be used for programming with DAQ cards Advanced users also have another option for register level programming although this option is not recommended because of it laborious and time consuming nature DLL Driver Advantech s DLL Driver software can be downloaded...

Страница 10: ...eve superior signal quality the signal wires are twisted to form a twisted pair cable reducing cross talk and noise from other signal sources Furthermore the analog and digital lines are separately sheathed and shielded to neutralize EMI EMC problems Wiring Boards The ADAM 3937 is a 37 pin D type wiring terminal module for DIN rail mounting This terminal module can be connected to Advantech PC Lab...

Страница 11: ...Chapter 2 2 Installation ...

Страница 12: ...he Relay Outputs Users may want the ability to clear each relay output when the system or PC issues a reset signal on the PCIE bus or to clear relays only as part of a system bootup The PCIE 1765 card satisfies both of these needs with the provision of jumper JP2 Depending on the application this may allow relay outputs to be configured as OFF without requiring a complete shutdown of card controll...

Страница 13: ...entify each card using their different device numbers The default board ID value is 0 When adjusting the board ID value refer to Table 2 2 to configure the DIP switch Note On 0 Off 1 Table 2 2 Board ID Settings SW1 Board ID dec Switch Position default 1 ID3 2 ID2 3 ID1 4 ID0 0 ON ON ON ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF 6 ON OFF OFF ON 7 ON OFF OFF OFF ...

Страница 14: ...ssignments for the 37 pin I O connector on the PCIE 1765 card are shown in Figure 2 2 Figure 2 2 I O connector pin assignments NOn n 0 11 Normally open pin of the relay output COMn n 0 11 Common pin of the relay output NCn n 0 11 Normally closed pin of the relay output ...

Страница 15: ... install the I O device for the PCIE 1765 card run the Advantech Device Man ager program accessible via Start Programs Advantech Automation Device Manager Advantech Device Manager 2 Users can then view the device s already installed on the system if any via the installed devices list If the software and hardware installation are complete you should see the PCIE 1765 card included on the installed ...

Страница 16: ...PCIE 1765 User Manual 10 ...

Страница 17: ...Chapter 3 3 Signal Connections ...

Страница 18: ...e application system is sending and receiving data correctly A good signal connection can prevent unnecessary and costly damage to your PC and other hardware devices 3 2 Relay Connections After system power on the initial relay output status of the PCIE 1765 card should be as shown below Figure 3 1 Relay output connection ...

Страница 19: ...Appendix A A Specifications ...

Страница 20: ...eakdown Voltage Between coil and contacts 5000 VAC Between open and contacts 1000 VAC Operating Time 7 ms typical Release Time 2 ms typical Life Expectancy 30 x 106 cycles 2A 250 VAC I O Connector Type 37 pin D type female Dimensions 168 x 100 mm 6 6 x 3 9 in Power Consumption 3 3V 250 mA typical 3 3V 2500mA max Temperature Operating 0 60 C 32 140 F Storage 40 70 C 40 158 F Relative Humidity 5 95 ...

Страница 21: ...Appendix B B Block Diagram ...

Страница 22: ...PCIE 1765 User Manual 16 B 1 Block Diagram Appendix A ...

Страница 23: ...17 PCIE 1765 User Manual Appendix B Block Diagram ...

Страница 24: ...re subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permission from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2018 ...

Отзывы: