15
Chapter 4
The following list shows the function of each VR:
VR Function
VR1 A/D full scale (gain)
VR2 A/D bipolar offset
VR3 A/D unipolar offset
VR4 PGIA initial offset
TP1 PGIA output
4.3 A/D Calibration
Regular and accurate calibration procedures ensure the maximum possi-
ble accuracy. The ADCAL.EXE calibration program leads you through
the whole A/D offset and gain adjustment procedure. The basic steps are
outlined below:
1.
Set analog input channel AI0 as single-ended, bipolar, range
±5 V and connect to the ground.
2.
Read TP1 as V
G1
.
3.
Change AI0 range to ±0.625 V and read TP1 as V
G8
.
4.
Adjust VR4 until -0.05 mV < V
G1
- V
G8
< 0.05 mV.
5.
Repeat steps 1 ~ 4 until ther is no more need to adjust VR4.
6.
Set analog input channel AI0 as single-ended, bipolar, range ±5 V,
and set AI1 as single-ended, unipolar, range 0 to 10 V.
7.
Connect a DC voltage source with value equal to 0.5 LSB
(-4.9959 V) to AI0.
8.
Adjust VR2 until the output codes from the card's AI0 flickers
between 0 and 1.
9.
Connect a DC voltage source with a value of 4094.5 LSB (4.9953
V) to AI0.
10.
Adjust VR1 until the output codes from the card's AI0 flickers
between 4094 and 4095.
11.
Repeat step 7 to step 10, adjusting VR2 and VR1.
12.
Connect a DC voltage source with value equal to 2047.5 LSB
(4.9959 V) to AI1.
13.
Adjust VR3 until the output codes from the card's AI1 flickers
between 2047 and 2048.
Содержание PCI-1715U
Страница 1: ...PCI 1715U 32 ch Isolated Analog Input Card User Manual...
Страница 8: ...PCI 1715U User Manual viii...
Страница 9: ...2 CHAPTER 1 Overview...
Страница 11: ...2 CHAPTER 2 Installation...
Страница 15: ...2 CHAPTER 3 Signal Connections...
Страница 21: ...2 CHAPTER 4 Calibration...
Страница 25: ...2 APPENDIX A Specifications...
Страница 28: ...PCI 1715U User Manual 20...