COM2 RS-232/422/485 mode selector (JESTCOM2)
Users can use JESTCOM2 to select among RS-232/422/485 modes for COM2. The
default setting is RS-232.
Figure 1.3 COM2 RS-232/422/485 jumper setting
Table 1.7: COM2 RS-232/422/485 mode selector
Function
Jumper Setting
RS-232
(5-6) + (7-9) + (8-10) + (13-15) + (14-16) closed
RS-422
(3-4) + (9-11) + (10-12) + (15-17) + (16-18) closed
RS-485
(1-2) + (9-11) + (10-12) + (15-17) + (16-18) closed
Note!
RS-485 does not support auto flow control.
RS232
RS422
RS485