4 MIC-770 V3 Startup Manual
Internal USB 2.0 Installation
1. Undo 4 screws and remove the bottom cover.
2. Loosen the screw and adjust the bracket size in ac-
cordance with the USB dongle size.
3.
Install the USB dongle in the first socket. Only the first
socket is functional.
4. Secure the screw and replace the bottom cover and
secure with screws.
CPU Installation
1. Undo 4 screws and remove the bottom cover.
2. Undo 4 screws to remove the storage tray.
3. Undo 7 screws to remove the memory & the M.2
thermal cover.
4. Undo 4 screws in the corner of the chassis.
5. Undo 4 screws around the CPU to release the CPU
heatsink.
6. Remove the CPU heatsink and install the CPU.
7. Smear thermal grease onto the CPU.
8. Replace the CPU heatsink, memory, & M.2 thermal
cover, storage tray, and bottom cover.
Mounting Kit Installation
1. Take the mounting kit from the accessory box.
2. Secure with 4 screws (P/N: 1930007259-01, M4x4L F/S
D=8.5 H=1.5 (2+) ST/H BZn-NK) and install the system
on a table.
Simple Maintenance Process (Cont.)
Safety Instructions
1. Read these safety instructions carefully.
2. Keep this Startup Manual for later reference.
3. Disconnect this equipment from any AC outlet before
cleaning. Use a damp cloth. Do not use liquid or spray
detergents for cleaning.
4. For plug-in equipment, the power outlet socket must
be located near the equipment and must be easily
accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installa-
tion. Dropping it or letting it fall may cause damage.
7. The openings on the enclosure are for air convection.
Protect the equipment from overheating. DO NOT
COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct
before connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on
it. Do not place anything over the power cord.
10. All cautions and warnings on the equipment should be
noted.
11. If the equipment is not used for a long time, disconnect
it from the power source to avoid damage by transient
overvoltage.
12. Never pour any liquid into an opening. This may cause
fire or electrical shock.
13. Never open the equipment. For safety reasons, the
equipment should be opened only by qualified service
personnel.
14. If one of the following situations arises, get the equip-
ment checked by service personnel:
•
The power cord or plug is damaged.
•
Liquid has penetrated into the equipment.
•
The equipment has been exposed to moisture.
•
The equipment does not work well, or you cannot get
it to work according to the user manual.
•
The equipment has been dropped and damaged.
•
The equipment has obvious signs of breakage.
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRON-
MENT WHERE THE STORAGE TEMPERATURE
MAY GO BELOW -40 °C (-40 °F) OR ABOVE 85 °C
(185 °F). THIS COULD DAMAGE THE EQUIPMENT.
THE EQUIPMENT SHOULD BE IN A CONTROLLED
ENVIRONMENT.
Simple Maintenance Process (Cont.)