background image

ICR-2834

2. Hardware Functionality

See Chapter

1.3

for the product hardware overwiew. Table

1

lists a short description of the

hardware, including the links to the chapters with a detailed description.

2.1

SIM Card Slots

Slots for two SIM cards are located on the front panel of the router under a metal cover.

It is necessary to insert an activated SIM card, to work properly. If the PIN is required for the
SIM, enter it in the router’s web interface. The SIM cards may have different APNs (Access
Point Names) adjusted. The SIM card changing procedure is described below.

Type of SIM cards: Mini SIM (2FF) 25.0 x 15.0 x 0.76 mm.

Inserting the SIM card:

Always disconnect the router from the power supply before handling the SIM card.

Release two screws on the SIM card cover and swipe up the cover.

To remove an inserted SIM card, use the flat end of a spudger, or your fingernail,
press the SIM card slightly into its slot until you hear a click. After hearing this click,
release the card, and it will pop out of its slot.

To insert a SIM card push card into the slot until it clicks into place.

Swipe down the cover and tight the cover screws.

Figure 5: SIM Cards Insertion

14

Содержание Libratum ICR-2834

Страница 1: ...LTE Industrial Router ICR 2834 USER MANUAL ...

Страница 2: ...ject to change without notice and does not represent a commitment on the part of Advantech Advantech Czech s r o shall not be liable for incidental or consequential damages resulting from the furnish ing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is fo...

Страница 3: ...ic situations Information notice Useful tips or information of special interest GPL license Source codes under GPL license are available at https icr advantech cz source code address Advantech Czech s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Document No MAN 0067 EN revision from August 25 2022 Released in the Czech Republic ii ...

Страница 4: ...et Interfaces 15 2 4 Power Supply 16 2 5 I O Port Interfaces 17 2 6 Serial Interfaces 18 2 7 USB Port 20 2 8 LED Status Indication 21 2 9 Reset Functions 22 3 First Use 24 3 1 Powering up the Router 24 3 2 Router Configuration 24 4 Technical Specifications 26 4 1 Basic Parameters 26 4 2 Standards and Regulations 27 4 3 Type Tests and Environmental Conditions 28 4 4 Parameters of Cellular Module 29...

Страница 5: ...ICR 2834 Appendix C Regulatory Safety Information 37 Appendix D Related Documents 39 iv ...

Страница 6: ... Top View 10 9 Position of the DIN Rail Clip 12 10 Removing Router from the DIN Rail 12 11 Label Example 13 5 SIM Cards Insertion 14 6 Ethernet Connector Pinout 15 7 Connection of Power Supply 16 8 Position of the Grounding Screw 16 9 I O Connector Pinout 17 10 Functional Scheme of the Binary Interface 17 11 Both interfaces in RS485 mode 18 12 Both interfaces in RS232 mode 19 13 USB Connector Pinn...

Страница 7: ...erface switched to RS485 mode 18 8 Connection of the first serial interface switched to RS232 mode 19 9 Connection of the second serial interface switched to R232 mode 19 10 USB Connector Pinnout 20 11 LED Status Indication 21 12 Overview of Router Reboot and Reset 23 13 Basic Parameters 26 14 Standards and Regulations 27 15 Type Tests and Environmental Conditions 28 16 Technical Parameters of Cel...

Страница 8: ...al ports four digital in puts together with two digital outputs with one USB 2 0 host interface and with 11 LEDs for status indication GNSS is also supported by some models The router supports VPN tunnel creation using various protocols to ensure safe commu nications The router provides diagnostic functions which include automatic monitoring of the wireless and wired connections automatic restart ...

Страница 9: ...ples The router is primarily intended for these four basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN II Backed up access to the Internet from LAN Figure 2 Backed up Access to the Internet 3 ...

Страница 10: ...ICR 2834 III Secure networks interconnection or using VPN Figure 3 Using VPN Tunnel IV Serial Gateway Figure 4 Serial Gateway 4 ...

Страница 11: ...iption 1 LEDs Status LED indication see Chapter 2 8 2 SIM slots Mini SIM Two SIM card slots see Chapter 2 1 3 ANT SMA Connector for the first main antenna of the cellular mod ule see Chapter 2 2 and Chapter 4 4 for cellular module parameters 4 DIV SMA Connector for the first diversity antenna of the cellular module see Chapter 2 2 and Chapter 4 4 for cellular mod ule parameters 5 USB USB A USB A t...

Страница 12: ...odule GNSS ETH0 ETH1 USB four binary inputs two binary outputs two SIM readers ICR 2834GP plastic box LTE Cat 4 with 3G 2G fallback module GNSS ETH0 ETH1 USB four binary inputs two binary outputs two SIM readers ICR 2834GA01 metal box LTE Cat 4 with 3G 2G fallback module GNSS ETH0 ETH1 USB four binary inputs two binary outputs two SIM readers accessories with Ethernet cable two antennas and EU pow...

Страница 13: ...igure Q ty 1 Router in metal or plastic box 1 pcs 2 DIN rail clip with screws screws differ for metal and plastic versions 1 set 3 2 pin terminal block for power supply deployed on the router 1 pcs 4 16 pin terminal block for serial and I O interfares deployed on the router 1 pcs 5 Printed Quick Start Guide notes 1 pcs Table 1 Contents of Package 7 ...

Страница 14: ...TH part number Antenna 5G LTE It can be ordered separately under ANT LTE5G 025 part number Wall mount power supply 12V 1A with EU plug It can be ordered separately under BB RPS v2 EU part number Wall mount power supply 12V 1A with UK plug It can be ordered separately under BB RPS v2 UK part number Wall mount power supply 12V 1A with US plug It can be ordered separately under BB RPS v2 US part numb...

Страница 15: ... 6 Product Dimensions For the dimensions of the product in metal and plastic boxes see the figures below Note that all sizes are measured in millimeters Figure 5 Metal box Front View Figure 6 Metal box Top View 9 ...

Страница 16: ...ICR 2834 Figure 7 Plastic box Front View Figure 8 Plastic box Top View 10 ...

Страница 17: ...ard For whip antennas it is recommended to observe a minimum distance of 6 cm from ca bles and metal surfaces on every side in order to avoid interference When using an external antenna separate from the switchboard it is necessary to fit a lightning conduc tor When mounting a router on sheet steel we recommend using a cable antenna For all cables we recommend to bind the bunch and for this we rec...

Страница 18: ...st differs by the crews used When mounting the DIN rail clip tighten the screws with max torque of 0 4 Nm Figure 9 Position of the DIN Rail Clip To remove the router from the DIN rail it is necessary to lightly push down the router so that the bottom part of the DIN rail clip hitched to the DIN rail get out of this rail and then fold out the bottom part of the router away from the DIN rail see Fig...

Страница 19: ...ICR 2834 1 9 Product Label An example of the product label with all the information printed on it is in the figure below Figure 11 Label Example 13 ...

Страница 20: ...nt APNs Access Point Names adjusted The SIM card changing procedure is described below Type of SIM cards Mini SIM 2FF 25 0 x 15 0 x 0 76 mm Inserting the SIM card Always disconnect the router from the power supply before handling the SIM card Release two screws on the SIM card cover and swipe up the cover To remove an inserted SIM card use the flat end of a spudger or your fingernail press the SIM...

Страница 21: ...ng moment for screwing the antenna to the SMA connector is 0 9 Nm The diversity antenna improves the radio capability of the router at low signal strength 2 3 Ethernet Interfaces The panel socket of RJ45 is used for Ethernet interface The pinout of the socket is shown in Figure 6 and described in Table 3 Figure 6 Ethernet Connector Pinout Pin Signal mark Description 1 TXD Transmit Data positive po...

Страница 22: ...48 V DC see the connection scheme on Figure 7 Protection against reversed polarity without signaling is built into the router For correct operation it is necessary that the power source is able to supply a peak current of 1 A Unit has to be supplied by a power supply specified as a Limited Power Source LPS or CEC NEC Class 2 source of supply All metal parts of the router in a metal box including t...

Страница 23: ...e third binary input 7 BIN3 The fourth binary input 16 BOUT0 The first binary output 8 BOUT1 The second binary output 5 13 GND Ground common negative pole Table 5 I O Ports Pinout The I O interface is not eletrically isolated from the router The I O user interface is designed for binary input processing and binary output control For detailed electrical parameters see Chapter 4 6 The functional sch...

Страница 24: ... of the terminal socket If switches are switched off serial interfaces are switched to operate as RS485 see Fig ure 11 Table 6 and Table 7 Figure 11 Both interfaces in RS485 mode Pin Signal mark Description 2 D In Out 1 D In Out 5 GND Ground Table 6 Connection of the first serial interface switched to RS485 mode Pin Signal mark Description 10 D In Out 9 D In Out 13 GND Ground Table 7 Connection of...

Страница 25: ... TXD Transmit Data 3 RTS Request to Send 4 CTS Clear to Send 5 GND Ground Table 8 Connection of the first serial interface switched to RS232 mode Pin Signal mark Description 9 RXD Received Data 10 TXD Transmit Data 11 RTS Request to Send 12 CTS Clear to Send 13 GND Ground Table 9 Connection of the second serial interface switched to R232 mode The serial interfaces are not eletrically isolated from...

Страница 26: ...nt the drive Use the dmesg command to see the list of recently connected devices In the output of the command find out the entry for the microSD card for example sda sda1 To mount the card to to mnt directory use the mount command mount dev sda1 mnt For more information about the commands for creating mounting checking and unmounting a file system on a USB Flash Drive see the application note for ...

Страница 27: ...reen Orange Red On Blinking Fast blinking 4G technology is used by the active SIM 3G technology is used by the active SIM 2G technology is used by the active SIM SIG Green Orange Red On Blinking Fast blinking Good signal Fair signal Poor signal SIM1 Green Red On Fast blinking SIM1 is selected SIM1 card problem missing SIM1 or PIN not entered SIM2 Green Red On Fast blinking SIM2 is selected SIM2 ca...

Страница 28: ...gency factory reset If the router is unable to boot up due to the bad configura tion turn off the router disconnect the power supply Push and hold the RST button turn on the router and hold the RST button for at least 10 seconds This will return the configuration of the router to the default one It is recommended to back up the settings of the router configuration prior to performing the factory r...

Страница 29: ...on manual Press the Reboot menu item in the web interface Press the RST button and hold il less than 4 sec onds Factory Reset Restores the default configuration and reboots the router Hold the RST button for more than 4 seconds If it does not help router does not start at all turn off the router power supply Push and hold the RST button then turn on the router and hold the RST button for more than...

Страница 30: ... by default See the product label on the router for its default password Log in to the web interface by the root user and his password If logged in successfully the user will have access to the router web interface see Figure 15 See the configuration manual 2 of the router for a detailed description and examples of the router configuration After logging on to the device for the first time we stron...

Страница 31: ...ICR 2834 Figure 15 Router s Web Interface A detailed description of the router settings in the web interface can be found in the configura tion manual of the router 25 ...

Страница 32: ...ry for RTC CR1225 Consumption Idle Average Peak 1 6 W 3 1 W 7 3 W Dimensions of device w o clip 113 2 x 80 3 x 42 mm metal box 117 x 83 8 x 51 4 mm plastic box DIN rail clip specification DIN 35 mm EN 60715 Weight 300 g metal box 240 g plastic box Antenna connectors ANT DIV GNSS SMA connectors for LTE 50 Ω R SMA connector for GNSS 50 Ω Interfaces ETH0 ETH1 USB SERIAL I O RJ 45 socket for 10 100 Mb...

Страница 33: ...301 908 13 EN 303 413 EMC EN 301 489 1 EN 301 489 19 EN 301 489 52 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 2 EN 61000 6 3 EN 55032 Safety IEC 62368 1 IEEE 802 3 Transportation E Mark E8 homologation number 10R 06 13493 National CE UKCA compliant Environmental REACH RoHS3 and WEEE compliant Table 14 Standards and Regulations 27 ...

Страница 34: ... kHz L3 Surge EN 61000 4 5 DC ETH AC DC 1 kV 1 2 50 8 20 Tr Th us L2 1 kV 1 2 50 8 20 Tr Th us L2 2 kV 1 2 50 8 20 Tr Th us L3 RF conducted EN 61000 4 6 DC ETH RS232 RS485 I O AC DC 10V 0 15 80MHz 80 AM 1kHz L3 10V 0 15 80MHz 80 AM 1kHz L3 10V 0 15 80MHz 80 AM 1kHz L3 10V 0 15 80MHz 80 AM 1kHz L3 10V 0 15 80MHz 80 AM 1kHz L3 10V 0 15 80MHz 80 AM 1kHz L3 Dips interruptions EN 61000 4 11 AC DC dip 0...

Страница 35: ...B8 900 MHz B3 1800 MHz B1 2100 MHz B7 2600 MHz Bit rates up to 150 Mbps DL 50 Mbps UL HSPA UMTS parameters HSPA 3GPP Release 7 UMTS 3GPP Release 4 Supported frequencies B8 900 MHz B3 1800 MHz B1 2100 MHz Bit rates max 21 Mbps DL 5 7 Mbps UL EDGE GPRS parameters Supported frequencies B5 850 MHz B8 900 MHz B3 1800 MHz B2 1900 MHz Bit rates max 237 kbps DL 237 kbps UL Table 16 Technical Parameters of...

Страница 36: ...f power supply for active antenna Frequency GPS min 1574 4 MHz typ 1575 42 MHz max 1576 4 MHz GLONASS min 1597 5 MHz typ 1575 42 MHz max 1605 9 MHz Tracking Sensitivity open sky GPS active antena 159 dBm GLONASS active antenna 158 dBm GPS passive anttenna 156 dBm GLONASS passive antenna 156 dBm Acquisition Sensitivity open sky GPS active antena 147 dBm GLONASS active antenna 146 dBm GPS passive an...

Страница 37: ...and io get commands see Commands and Scripts application note Logical1 Voltage Current Status2 1 3 V 0 5 mA Off 0 5 V 0 8 mA On 0 12 V 1 6 mA On 0 48 V 3 4 mA On Table 18 Electrical Characteristics of Binary Inputs The maximum binary output load is 500 mA at 48 V 1 The binary status returned by the io get shell command 2 The binary status returned by the status ports shell command and displayed on...

Страница 38: ...M926EJ S CPU frequency 600 MHz CPU power 4 72 DMIPS MHz Flash memory 4 MB of NOR 4 096 MB of eMMC 838 MB for Router Apps 512 MB for customer data RAM size 128 MB Watchdog HW Watchdog RTC Battery Backup RTC TPM1 Trusted Platform Module TPM 2 0 Table 19 System Configuration 1 Not assembled by default for a dedicated customer order only 32 ...

Страница 39: ... the neighbouring cells have a similar signal strength you will need to use a directional antenna For proper operation the signal levels have to be good Try to enable automatic ping from the router which will check the connection when there are no data running and in the case of a failed ping restart the connection This can be done on the Mobile WAN Configuration page in the router in the Check co...

Страница 40: ...e with router s IP address You can verify a Firewall by accessing remotely to the router s Web interface The operator may not provide the address of DNS server and without DNS server s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the System Log DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server ...

Страница 41: ...ers only You can use SFTP on all routers to transfer files to from the router If having troubles with FTP on v2 routers make sure you have FTP enabled Configuration section Services FTP Then you can connect with any client on port 21 with name and password same as for the Web interface If having troubles with SFTP make sure you have SSH enabled Configuration section Services SSH Then you can conne...

Страница 42: ...eu Web www advantech com Customer Support for NAM Advantech B B SmartWorx 707 Dayton Road Ottawa IL 61350 USA Phone 1 800 346 3119 Monday Friday 7 a m to 5 30 p m CST Fax 1 815 433 5109 E mail support advantech bb com Web www advantech bb com Customer Support for Asia Phone 886 2 2792 7818 1299 Monday Friday 9 a m to 5 30 p m UTC 8 Fax 886 2 2794 7327 E mail icg support advantech com tw Web www ad...

Страница 43: ... expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature Only routers with appropriate certification and labelling should be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the...

Страница 44: ...inimize the environmental impact This product contains high quality materials and components which can be recycled At the end of it s life this pro duct MUST NOT be mixed with other commercial waste for disposal The device contains a battery Re move the battery from the device before disposal The battery in the device needs to be disposed of apart accordingly Check the terms and conditions of your...

Страница 45: ...elated Documents 1 Quick Start Guide for v2i Platform 2 Configuration Manual for v2i Platform EP Product related documents and applications can be obtained on Engineering Portal at https icr advantech cz download address 39 ...

Страница 46: ...lies with Radio Equipment Regulations 2017 S I 2017 No 1206 We Advantech Czech s r o declare that the radio equipment narrated in this user s manual complies with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the following internet address icr advantech cz eudoc ...