Web GUI Monitoring & Control
Figure 4.9: Alarms and Warnings Monitoring Window
4.6.3
General
The following paragraphs detail the general alarms shown in
Figure 4.9.
4.6.3.1
Lock State
This property allows an alarm or warning to be raised if the modulator is unlocked.
4.6.3.2
FPGA Loading Failed
This property allows an alarm or warning to be raised if one or more of the FPGA devices in the
modulator fail to configure correctly.
4.6.3.3
FPGA Done Line Failure
This property allows an alarm or warning to be raised if the FPGA devices in the modulator fail to
exit the programming mode.
4.6.3.4
Board Temperature
This property allows an alarm or warning to be raised if the temperature of the modulator board
exceeds the user specified temperature limit.
4.6.3.5
FPGA Temperature
This property allows an alarm or warning to be raised if the core temperature of one or more of
the FPGA devices exceeds the design limit.
4.6.3.6
Output disabled
This property allows an alarm or warning to be raised if the output of the modulator is disabled.
For example the input data stream is removed.
4.6.3.7
Output Calibration
This property allows an alarm or warning to be raised if the modulator is uncalibrated
4-12
SBM75e Series Modulator Installation and Operation Manual
Содержание L-Band Satellite Modulator
Страница 14: ...Getting Started 1 8 SBM75e Series Modulator Installation and Operation Manual...
Страница 45: ...Front Panel Monitoring Control SBM75e Series Modulator Installation and Operation Manual 3 15...
Страница 73: ...Web GUI Monitoring Control 4 28 SBM75e Series Modulator Installation and Operation Manual...
Страница 78: ...Technical Specification SBM75e Series Modulator Installation and Operation Manual A 5...
Страница 90: ...Glossary B 12 SBM75e Series Modulator Installation and Operation Manual...