IDK-2121W User Manual
4
Note 2:
9 points position
Note 3
: The luminance uniformity of 9 points is defined by dividing the maximum
luminance values by the minimum test point luminance
Note 4
: Measurement method
The LCD module should be stabilized at given temperature for 30 minutes to avoid
abrupt temperature change during measuring. In order to stabilize the luminance, the
measurement should be executed after the backlight has been on for 30 minutes in a
stable, windless and dark room. Optical Equipment: DT-100, or equivalent
Note 5
: Definition of response time:
The output signals of the photo detector are measured when the input signals are
changed from “Full Black” to “Full White” (rising time), and from “Full White” to “Full
Black ”(falling time), respectively. The response time is the interval between the 10%
and 90% of amplitudes. Please refer to the figure as below.
50 %
90 %
90 %
50 %
10 %
10 %
Minimum Brightness of nine points
W9
=
Maximum Brightness of nine points
100
90
10
0
%
Optical
response
White
Black
White
Tf
Tr
90
10
0
Optical
response
White
Black
White
Tr
Содержание IDK2121WNK2FHA2EES
Страница 1: ...User Manual IDK2121WNK2FHA2E ES TFT LCD 21 5 FHD LED Backlight...
Страница 7: ...Chapter 1 1 Overview...
Страница 13: ...7 IDK 2121W User Manual Chapter 1 Overview Rear View...
Страница 14: ...IDK 2121W User Manual 8 1 6 2 IDK 2121WN 1KFHA1E Front View...
Страница 15: ...9 IDK 2121W User Manual Chapter 1 Overview Rear View...
Страница 16: ...IDK 2121W User Manual 10...
Страница 17: ...Chapter 2 2 Electrical Characteristics...
Страница 20: ...IDK 2121W User Manual 14...
Страница 21: ...Chapter 3 3 Signal Characteristics...
Страница 27: ...Chapter 4 4 Connector Pin Assignment...
Страница 31: ...Chapter 5 5 Touch Screen Touch Controller...
Страница 36: ...IDK 2121W User Manual 30 5 2 3 Physical dimension ETM RES04C EEH4EE Touch Control Board Unit mm...
Страница 37: ...Appendix A A Handling Precautions...