Table 2.1: Timing Specifications:
Parameter
Value
Units
Min
Typ
Max
T1
0.5
-
10
ms
T2
0
-
50
ms
T3
0
-
50
ms
T4
500
-
-
ms
T5
450
-
-
ms
T6
200
-
-
ms
T7
10
-
100
ms
T8
10
-
-
ms
T9
10
-
-
ms
T10
20
-
50
ms
Note1!
1.
The supply voltage of the external system for the module input
should be the same as the definition of Vcc.
2.
When the backlight turns on before the LCD operation of the LCD
turns off, the display may momentarily become an abnormal
screen.
3.
In case of VCC = off level, please keep the level of input signals on
low or keep a high impedance.
4.
T4 should be measured after the module has been fully discharged
between power off and on period.
5.
Interface signal shall not be kept at high impedance when the
power is on.
6.
INX won't take any responsibility for the products which are dam
-
aged by the customers not following the Power Sequence.
7.
There might be slight electronic noise when LCD is turned off (even
backlight unit is also off). To avoid this , we suggest using" Vcc fall
-
ing timing" to follow "T7 spec".
Содержание IDK-1115WP-45FHA2
Страница 4: ...IDK 1115WP 45FHA2 User Manual iv ...
Страница 7: ...Chapter 1 1 Overview ...
Страница 11: ...Chapter 2 2 LCD Display ...
Страница 24: ...IDK 1115WP 45FHA2 User Manual 18 ...
Страница 25: ...Chapter 3 3 Touchscreen Touch Controller ...
Страница 28: ...IDK 1115WP 45FHA2 User Manual 22 ...
Страница 29: ...Appendix A A LCD Optical Characteristics ...
Страница 32: ...IDK 1115WP 45FHA2 User Manual 26 Figure A 3 Measurement Method Note Definition of response time ...
Страница 34: ...IDK 1115WP 45FHA2 User Manual 28 ...
Страница 35: ...Appendix B B Safety Precautions ...