Advantech iDAQ-815 Скачать руководство пользователя страница 5

v

iDAQ-815 User Manual

 

Safety Instructions

1.

Read these safety instructions carefully.

2.

Retain this user manual for future reference.

3.

Disconnect the equipment from all power outlets before cleaning. Use only a 

damp cloth for cleaning. Do not use liquid or spray detergents.

4.

For pluggable equipment, the power outlet socket must be located near the 

equipment and easily accessible.

5.

Protect the equipment from humidity.

6.

Place the equipment on a reliable surface during installation. Dropping or letting 

the equipment fall may cause damage.

7.

The openings on the enclosure are for air convection. Protect the equipment 

from overheating. Do not cover the openings.

8.

Ensure that the voltage of the power source is correct before connecting the 

equipment to a power outlet.

9.

Position the power cord away from high-traffic areas. Do not place anything over 

the power cord.

10.

All cautions and warnings on the equipment should be noted.

11.

If the equipment is not used for a long time, disconnect it from the power source 

to avoid damage from transient overvoltage.

12.

Never pour liquid into an opening. This may cause fire or electrical shock.

13.

Never open the equipment. For safety reasons, the equipment should be 

opened only by qualified service personnel.

14.

If any of the following occurs, have the equipment checked by service person

-

nel:

The power cord or plug is damaged.

Liquid has penetrated the equipment.

The equipment has been exposed to moisture.

The equipment is malfunctioning, or does not operate according to the user 

manual.

The equipment has been dropped and damaged.

The equipment show obvious signs of breakage.

15.

Do not leave the equipment in an environment with a storage temperature of 

below -20 °C (-4 °F) or above 60 °C (140 °F) as this may damage the compo

-

nents. The equipment should be kept in a controlled environment.

16.

CAUTION: Batteries are at risk of exploding if incorrectly replaced. Replace only 

with the same or equivalent type as recommended by the manufacturer. Discard 

used batteries according to the manufacturer’s instructions.

17.

In accordance with IEC 704-1:1982 specifications, the sound pressure level at 

the operator's position does not exceed 70 dB (A).

DISCLAIMER: These  instructions  are  provided  according  to  IEC  704-1  standards.

Advantech disclaims all responsibility for the accuracy of any statements contained

herein.

Содержание iDAQ-815

Страница 1: ...User Manual iDAQ 815 8 ch RTD Industrial DAQ Module ...

Страница 2: ...ssumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced free of charge during the warranty period For out of warranty repairs customers will be billed according to the cost of...

Страница 3: ...armful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference In this event users are required t...

Страница 4: ... your dealer immediately iDAQ 815 iDAQ 815 x 1 20 pin terminal block x 2 Startup Manual x 1 Warning Warnings indicate conditions that if not observed can cause personal injury Caution Cautions are included to help prevent hardware damage and data losses E g Batteries are at risk of exploding if incorrectly installed Do not attempt to recharge force open or heat the battery Replace the battery only...

Страница 5: ...ur liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If any of the following occurs have the equipment checked by service person nel The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed to moisture The equipment is malfunc...

Страница 6: ...s könnte einen Brand bzw elektrischen Schlag aus lösen 13 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 14 Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen Netzkabel oder Netzstecker sind beschädigt Flüssigkeit ist in das Ge...

Страница 7: ...To avoid electrical shock always disconnect the power from the PC chassis before manual handling Do not touch any components on the CPU card or other cards while the PC is powered on Disconnect the power before making any configuration changes A sudden rush of power after connecting a jumper or installing a card may damage sensitive electronic components ...

Страница 8: ...iDAQ 815 User Manual viii ...

Страница 9: ...ut signal connection 7 2 3 2 3 Wire RTD Input Signal Connection 7 Figure 2 3 3 wire RTD input signal connection 8 2 3 3 4 Wire RTD Input Signal Connection 9 Figure 2 4 4 wire RTD input signal connection 9 2 3 4 Pin Assignment 10 Chapter 3 Function Details 11 3 1 Function Details 12 3 2 Analog Input 12 3 2 1 Instant Analog Input Acquisition 12 Figure 3 1 Instant analog input acquisition 12 3 2 2 Bu...

Страница 10: ...iDAQ 815 User Manual x A 1 RTD Input 18 A 2 General 19 A 3 Function Block 19 Appendix B System Dimensions 21 B 1 System Dimensions 22 ...

Страница 11: ...Chapter 1 1 Start Using iDAQ 815 ...

Страница 12: ...rotary switch is in hexadecimal format For example A represents 10 in decimal format and F represents 15 in decimal for mat The number assigned to each iDAQ module follows a rule combining the Chas sisID and slot number Refer to section 3 4 for detailed information 1 3 3 Plug and Play Device The iDAQ modules are hot swappable in the iDAQ chassis The modules will be rec ognized instantly in the sof...

Страница 13: ...ges are available on the Advantech website http www advantech com The Advantech Navigator is a utility that allows you to set up configure and test your device and later store your settings in a proprietary database 1 To set up the I O device you could first run the Advantech Navigator program by accessing Start Programs Advantech Automation DAQNavi Advantech Nav igator The settings could also be ...

Страница 14: ...p of that the data log ging function is also available in DAQNavi MCM All the data can be saved not only in local storage but also in remote storage By introducing the DAQNavi MCM the DAQ system can become an IoT solution ready edge device For more information please search for DAQNavi MCM on the Advantech Support Portal https www advantech com support 1 8 FPGA Code Update The FPGA could also be u...

Страница 15: ...Chapter 2 2 Installation Guide ...

Страница 16: ...dules 1 Startup manual 1 Terminal blocks If anything in the packing list is missing please contact your local support for further assistance 2 2 Installation Below are the steps to insert the iDAQ modules into the iDAQ chassis 1 Insert the module and follow the guide rail to the end 2 Screw the two thumb screws tight onto the chassis Figure 2 1 iDAQ Module Install into iDAQ Chassis ...

Страница 17: ...l ground as shown by the red line in Figure 2 2 Assuming both lead wire resistances are equal RLEAD the measurement result can be calculated as follows where CODEADC is the output code of the ADC FSRADC is the full scale range of ADC for a 24 bit ADC it is equal to 224 VIN is the voltage measured by the ADC and VREF is the reference voltage of the ADC As can be seen in the equation the lead wire r...

Страница 18: ... and to the internal ground as shown by the blue line in Figure 2 3 Assuming all lead wire resistances are equal RLEAD the measurement result can be calculated as follows where CODEADC is the output code of the ADC FSRADC is the full scale range of ADC for a 24 bit ADC it is equal to 224 VIN is the voltage measured by the ADC and VREF is the reference voltage of the ADC Note that the second line o...

Страница 19: ...istor RRTD RTD lead 4 and to the internal ground as shown by the red line in Figure 2 4 Assuming all lead wire resistances are equal RLEAD the measurement result can be calculated as follows where CODEADC is the output code of the ADC FSRADC is the full scale range of ADC for a 24 bit ADC it is equal to 224 VIN is the voltage measured by the ADC and VREF is the reference voltage of the ADC As can ...

Страница 20: ...ve terminal n 0 7 3 7 11 15 23 27 31 35 EXCn Excitation current n negative terminal n 0 7 4 8 12 16 24 28 32 36 RTDn Resistor temperature detector n positive terminal n 0 7 5 9 13 17 25 29 33 37 RTDn Resistor temperature detector 0 negative terminal 6 10 14 18 26 30 34 38 NC No connection 1 2 19 20 21 22 39 40 ...

Страница 21: ...Chapter 3 3 Function Details ...

Страница 22: ...ment for the individual iDAQ module 3 2 1 Instant Analog Input Acquisition With instant analog input acquisition the software controls the sample timing The analog to digital converter ADC is continuously converting analog input signals by its maximum allowable conversion rate Each time the software sends a read instant analog input sample command the most recent conversion result is sampled as sh...

Страница 23: ...ch rising edge of the sample clock acquires one analog input sample The acquisition active period lasts until a stop trigger is received which ends the acquisition This is shown in Figure 3 3 Figure 3 3 Start and stop triggers of the analog input acquisition The start and stop of data acquisition can also be delayed in the number of samples after receiving the corresponding trigger signal As shown...

Страница 24: ...3 3 1 RTD Type There are many RTD types made by different materials such as platinum Pt nickel Ni copper Cu and nickel ferrite alloy NiFe Each type of RTD has different tem perature sensitivity which is the percentage of resistance change over unit tempera ture and measurable temperature range RTD is usually named after the material made with and the resistance value at 0 C For example a Pt100 RTD...

Страница 25: ...ogy for each configura tion shown above In 2 wire configuration the lead wire resistances cannot be separated from the RTD resistance Therefore 2 wire RTDs have the least accurate measurement result but are the least expensive solution In 3 wire configuration the lead wire resistances can be compensated if their values match for each lead With 3 wire RTDs a much more accurate result can be obtaine...

Страница 26: ...n the iDAQ system It s given following a naming rule of combining chassis ID model name and slot number You can change the description in Navigator or just leave it as default The descrip tion is used in your own program in order to get control or device handler from the device Figure 3 6 Device description shown in Navigator ...

Страница 27: ...Appendix A A Specifications ...

Страница 28: ...l channels High speed mode 2 5 ms max 400 S s per channel 20 ms total for all channels Bandwidth 3dB High resolution mode 4 7 Hz High speed mode 574 Hz Normal mode rejection Idle channel noise 50 Hz 1 Hz 79 dB min 60 Hz 1 Hz 78 dB min High speed mode None Isolation protection 600 VRMS Acquisition type Instant or buffered software configurable Buffered acquisition Sample rate 1 20 kHz max for all c...

Страница 29: ...General Module dimensions 100 x 80 x 25 mm 3 94 x 3 15 x 0 98 in Weight 170 g Operating temperature 20 C to 60 C 4 F to 140 F Storage temperature 40 C to 70 C 40 F to 158 F Operating humidity 10 to 90 RH non condensing Storage humidity 5 to 95 RH non condensing Vibration 5Grms random 5 500Hz 1hr axis Shock 30G half sine 11ms A 3 Function Block 150 C 0 75 C 0 75 C 0 6 C 150 C 1 00 C 1 00 C 0 75 C T...

Страница 30: ...iDAQ 815 User Manual 20 ...

Страница 31: ...Appendix B B System Dimensions ...

Страница 32: ...26 28 30 32 34 36 38 40 iDAQ 815 2 3 4 wire EXC0 RTD1 RTD iDAQ 815 iDAQ 815 8 ch 24 bit 400 S s RTD Input NC RTD0 EXC1 EXC2 RTD2 EXC2 EXC3 NC RTD3 RTD3 NC EXC4 NC EXC0 RTD0 EXC1 RTD1 RTD2 EXC3 NC RTD4 NC EXC4 EXC5 RTD5 EXC6 RTD6 EXC7 RTD7 NC RTD4 EXC5 RTD5 RTD6 EXC6 EXC7 RTD7 NC RTD7 EXC7 EXC7 RTD7 2 3 4 wire RTD RTD0 EXC0 EXC0 RTD0 ...

Страница 33: ...23 iDAQ 815 User Manual Appendix B System Dimensions ...

Страница 34: ...re subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permission from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2022 ...

Отзывы: