ICR-3201
4.3
Type Tests and Environmental Conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
Enclosure air
±
6 kV (crit. A)
±
8 kV (crit. A)
RF field AM
modulated
EN 61000-4-3
Enclosure
20 V/m (crit. A)
(80 – 10000 MHz)
10 V/m (crit. A)
(1 – 6 GHz)
Fast transient
EN 61000-4-4
Signal ports
Power ports
Ethernet ports
±
1 kV (crit. A)
±
2 kV (crit. A)
±
1 kV (crit. A)
Surge
EN 61000-4-5
Ethernet ports
Power ports
±
1 kV (crit. A), shielded cab.
±
2 kV (crit. A)
RF conducted
EN 61000-4-6
All ports
10 V/m (crit. A)
(0,15 – 80 MHz)
Radiated emission
EN 55032
Enclosure
Class B
Conducted
emission
EN 55032
DC power ports
Ethernet ports
Class B
Class B
Dry heat
EN 60068-2-2
MIL-STD-810G
SAE J1455
+75
◦
C *, 40 % rel. humidity
Cold
EN 60068-2-1
MIL-STD-810G
SAE J1455
-40
◦
C *
Damp heat
EN 60068-2-78
MIL-STD-810G
SAE J1455
95 % rel. humidity (+40
◦
C)
Vibration
EN 60068-2-64 ed. 2
MIL-STD-810G
SAE J1455
Vibration spectrum
A.3 (rolling stock)
Category 1 (3 axis, 8 hours
per axis)
Shock
EN 60068-2-27 ed. 2
MIL-STD-810G
SAE J1455
half-sine, 50 g peak, 11 ms
Table 14: Type tests and environmental conditions
23
Содержание ICR-3201 Series
Страница 1: ...LAN Industrial Router ICR 3201 USER MANUAL ...
Страница 5: ...ICR 3201 Appendix D Related Documents 32 iv ...