44
EKI-7708 Series User Manual
4.4.6
System Time
To access this page, click
System
>
System Time
.
Figure 4.14 System > System Time
The following table describes the items in the previous figure.
Item
Description
Enable SNTP
Click the radio button to enable or disable the SNTP.
SNTP/NTP Server
Address
Enter the address of the SNTP server. This is a text string of up to 64
characters containing the encoded unicast IP address or hostname of
a SNTP server. Unicast SNTP requests will be sent to this address. If
this address is a DNS hostname, then that hostname should be
resolved into an IP address each time a SNTP request is sent to it.
SNTP Port
Enter the port on the server to which SNTP requests are to be sent.
Allowed range is 1 to 65535 (default: 123).
Manual Time
Click the drop-down menus to set local date and time of the system.
Time Zone
Click the drop-down menu to select a system time zone.
Daylight Saving Time Click the drop-down menu to enable or disable the daylight saving
time settings.
Daylight Saving Time
Offset
Enter the offsetting variable in seconds to adjust for daylight saving
time.