14
EKI-6333AC-2G Series User Manual
2.2.3
Network Connection
For RJ45 connectors, data-quality, twisted pair cabling (rated CAT5 or better) is
recommended. The connector bodies on the RJ45 Ethernet ports are metallic and
connected to the GND terminal. For best performance, use shielded cabling.
Shielded cabling may be used to provide further protection.
Figure 2.13 Ethernet Plug & Connector Pin Position
Maximum cable length: 100 meters (328 ft.) for 10/100BaseT.
2.2.4
Power Connection
2.2.4.1
Overview
The EKI-6333AC-2G is powered by a passive 24V PoE injector.
1.
Locate the LAN1 port on the bottom of the access point.
2.
Connect one end of a Ethernet cable to a PoE injector.
Straight-thru Cable Wiring
Cross-over Cable Wiring
Pin 1
Pin 1
Pin 1
Pin 3
Pin 2
Pin 2
Pin 2
Pin 6
Pin 3
Pin 3
Pin 3
Pin 1
Pin 6
Pin 6
Pin 6
Pin 2
1
8
Warning!
Power down and disconnect the power cord before servicing or wiring
the device.
Caution!
Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the device.
Caution!
Disconnect the power cord before installation or cable wiring.
Содержание EKI-6333AC-2G Series
Страница 1: ...User Manual EKI 6333AC 2G Series IEEE 802 11 a b g n ac WiFi AP ...
Страница 9: ...Chapter 1 1Introduction ...
Страница 13: ...Chapter 2 2Getting Started ...
Страница 14: ...6 EKI 6333AC 2G Series User Manual 2 1 Hardware 2 1 1 Front View Figure 2 1 Front View ...
Страница 26: ...Chapter 3 3Web Interface ...