Страница 1: ...EKI 2725 5 port Industrial Unmanaged Gigabit Ethernet Switch User Manual...

Страница 2: ...m or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibilit...

Страница 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Страница 4: ...ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential a...

Страница 5: ...ything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transien...

Страница 6: ...age 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power b...

Страница 7: ...units mm 9 Figure 2 1 Front View of EKI 2725 9 Figure 2 2 Side View of EKI 2725 10 Figure 2 3 Rear View of EKI 2725 11 Figure 2 4 Top View of EKI 2725 12 2 3 Mounting 13 2 3 1 Wall mounting 13 Figure...

Страница 8: ...EKI 2725 User Manual viii...

Страница 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER...

Страница 10: ...ower input is fail P Fail LED will turn on and send an alarm through a relay output for notifying user 1 1 3 Flexible Mounting EKI 2725 is compact 37 x 140 x 95 mm and can be mounted on a DIN rail or...

Страница 11: ...egotiation Supports jumbo frame transmission up to 9Kbytes Provides surge EFT protection 3 000 VDC for power line Supports 4 000 VDC Ethernet ESD protection Provides Slim size DIN rail with IP30 metal...

Страница 12: ...ve Duplex Collision Power Power Consumption Max 4 6W Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 37 x 140 x 95 mm Enclosure IP30 Metal shell with solid...

Страница 13: ...UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 12 EN61000 6 2 Freefall IEC60068 2 32 Shock IEC6...

Страница 14: ...ation CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2725 Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution A...

Страница 15: ...7 Chapter2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER...

Страница 16: ...table Table 2 1 EKI 2725 LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Po...

Страница 17: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 2725...

Страница 18: ...EKI 2725 User Manual 10 Figure 2 2 Side View of EKI 2725...

Страница 19: ...11 Chapter2 Figure 2 3 Rear View of EKI 2725...

Страница 20: ...EKI 2725 User Manual 12 The power relay terminal block is located on the top Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2725...

Страница 21: ...mounted by using the included mounting kit Then hang on the EKI 2725 to the nails on the wall First use the screws included in the package to combine the EKI 2725 and metal mounting kit And then you...

Страница 22: ...eps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang th...

Страница 23: ...15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2...

Страница 24: ...I X to another hub or switch either MDI X or uplink MDI port The EKI 2725 supports auto crossover to make networking more easy and flexible You can connect any RJ 45 MDI X station port on the switch t...

Страница 25: ...17 Chapter2 Troubleshooting CHAPTER...

Страница 26: ...be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes commo...

Страница 27: ...19 Chapter2 Pin Assignment Wiring APPENDIX...

Страница 28: ...EKI 2725 User Manual 20 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A...