6
Electrical installation
7
Cable cover and strain relief
8
Further information
Notice:
• Ensure that the ground connection is correct!
• Choose a suitable position on the forklift for the ground connection.
• Sometimes the position from which the ground signal is to come is
specified by the vehicle manufacturer
• Position and connect the XMT 5 as close to the battery as possible.
• Do not attach the XMT 5 directly to a connector for a high-powered consumer
(e.g. an inverter for fork lift motors) as this could lead to
restarts, malfunctions or damage to the device.
• Some forklifts have a chassis that is connected to DC+.
Therefore, the XMT 5 chassis is also connected to DC+.
However, if you use peripheral devices that supply DC- to the
DLoG MTC 6 via an interconnector (such as a DC- serial port),
this will cause a short circuit. This will inevitably lead to malfunctions
or even a total system failure.
5
Mechanical installation
Position of the XMT 5 on the vehicle
• The driver‘s field of vision in the vehicle must not be obstructed.
• If you want to install a keyboard and scanner on the side of the XMT 5,
please allow enough space.
Overview of the installation steps
Before you mount the XMT 5 onto the vehicle:
• The automatic switch-off function must be configured.
• The forklift must be prepared (connection to ignition, observe correct voltage, etc.).
We recommend that the installation process is carried out in the following sequence
:
• Step 1: Secure the mounting bracket onto the vehicle
• Step 2: Attach the XMT 5 to the mounting bracket; please observe the assembly
instructions that come with the relevant mounting kit.
4
Wireless networks
The XMT 5 optionally contains a Summit WLAN card. Generally, the WLAN profile is set as
default in the factory by Advantech-DLoG for this card. If any adjustments are required, the
Summit Client Utility
tool for modifying the WLAN profile is available.
Summit Client Utility Program
• Start the
Summit Client Utility
program with the
SCU
-Icon on the desktop.
• Log on with the password „SUMMIT“ (all uppercase).
• Make the desired settings.
Tip
: Use the help function for this program to read details about the setting options.
!
Notice
: WLAN settings may be made only by
qualified technical staff.
!
User manuals / device drivers in the Download Center
Manuals and the latest device drivers for your Advantech-DLoG industrial PC can
be found in the
Downloads
menu at
www.advantech-dlog.com
.
If you have any further questions, please contact your Advantech-DLoG service partner or
contact us directly at:
DLoG GmbH
Industriestraße 15
www.advantech-dlog.com
D-82110 Germering
Phone: (+49) 89 / 41 11 91 - 999
Ground bolt
XMT 5 connectors,
24/48 VDC
XMT 5 connectors,
12/24 VDC
Once the XMT 5 and mounting bracket have been secured:
• Prepare the strain relief.
• Position the cables on the stress relief rail so that they will
fit through the openings in the cable cover.
• Mount the cables loosely on the strain relief rail.
Final steps:
• Fix the cables to the strain relief rail.
• Close the cable cover carefully, observing the assembly instructions provided
with the XMT 5.
Example for cable positioning
to the strain relief rail
Copyright 2011 by DLoG GmbH, Industriestraße 15, D-82110 Germering. All rights reserved.
Information in this document is subject to change without prior notice.
Quickstart Guide XMT 5 Series V1.00 DAN 885904E.00