background image

SPC-800(M) User Manual

34

3.

Pre-hole cut-outs 

4.

Fix the RAFI button assembly of the threaded ring.

5.

Attach the Button’s PCBA with M3 x 4pcs screw to the OP back side.

Содержание BOR-DE Series

Страница 1: ...User Manual SPC 815 M SPC 821 M BOR DE115W BOR DE121W W15 6 W21 5 TFT LED LCD Standalone Multi Touch Industrial Monitor with Extension Units...

Страница 2: ...owever Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties that may result from its use Acknowledgements Intel and Pentium are trademarks of...

Страница 3: ...ight Please consult your dealer for more details If you suspect that your product is defective product follow the steps outlined below 1 Collect all the information about the problem encountered for e...

Страница 4: ...rs are required to correct the interference at their own expense Technical Support and Assistance 1 Visit the Advantech website at www advantech com support to obtain the latest product information 2...

Страница 5: ...vice personnel 14 If one of the following occurs have the equipment checked by service person nel The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed t...

Страница 6: ...t uniquement par du personnel qualifi 13 Si l une des situations suivantes se pr sente faites v rifier l quipement par le personnel de service Un liquide a p n tr dans l quipement L quipement a t expo...

Страница 7: ...ME TYPE OU QUIVALENT RECOMMAND PAR LE FAB RICANT JETER LES BATTERIES US ES SELON LES INSTRUCTIONS DU FABRICANT VEUILLEZ CONTACTER LE FABRICANT ADVANTECH POUR LE REMPLACER ATTENTION Pour viter les cho...

Страница 8: ...SPC 800 M User Manual viii 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 20 4 60 140 16 17 IEC 704 1 1982 70 18 19 IEC 704 1 20 21 30 10 22 2 2 1 23...

Страница 9: ...ize model for Customer 12 1 4 Power 13 1 5 I O Ports Arrangement 14 Figure 1 1 Front view and Side view 14 Figure 1 2 Rear view for SPC 800 MLAG SPC 800 MLAP Series 14 Figure 1 3 Rear view for SPC 800...

Страница 10: ...SPC 800 M User Manual x...

Страница 11: ...Chapter 1 1 General Information...

Страница 12: ...n SPC 800 M can be a ubiquitous HMI in any kind of smart factory and even in the machines SPC 800 M can be a great visualization solution in different application in rugged regions The following are t...

Страница 13: ...ystem 1 x Plug In Block 1 x Ground Wire 100CM 1 x Cover IO 1 x Registration and Warranty Card 4 x Pole Mounting Blake Screws 1 2 2 Packing List for BOR DE Series Customize model for Customer 1 x Syste...

Страница 14: ...m W Vesa Mount Board Dimension W x D x H mm 145 x 104 x20 mm Enclosure Front bezel Die cast aluminum alloy Back housing Die cast aluminum alloy Mounting ARM mounting Pendant and Pedestal VESA mounting...

Страница 15: ...ut Button Button Cover Color Without Button Environ ment Humidity 85 40 C non condensing Operating Temperature 0 55 C without airflow Storage Tempera ture 20 60 C Degree and class of protection IP65 A...

Страница 16: ...l Die cast aluminum alloy Back housing Die cast aluminum alloy Mounting ARM mounting Pendant and Pedestal VESA mounting Power Input Voltage 24VDC 25 20 Power Consumption DP HDM RX 20 6W 32W System Des...

Страница 17: ...ithout Button Button Cover Color Without Button Environ ment Humidity 85 40 C non condensing Operating Temperature 0 55 C without airflow Storage Tempera ture 20 60 C Degree and class of protection IP...

Страница 18: ...e cast aluminum alloy Mounting ARM mounting Pendant and Pedestal VESA mounting Power Input Voltage 24VDC 25 20 Power Consumption DP HDM RX 20 6W 32W System Design Fanless I O USB USB 2 0x1 Type B USB...

Страница 19: ...0 C non condensing Operating Temperature 0 55 C without airflow Storage Tempera ture 20 60 C Degree and class of protection IP65 All around Shock Protection IEC 60068 2 27 Vibration Protection IEC 600...

Страница 20: ...e cast aluminum alloy Back housing Die cast aluminum alloy Mounting ARM mounting Pendant and Pedestal VESA mounting Power Input Voltage 24VDC 25 20 Power Consumption DP HDM RX 20 6W 32W System Design...

Страница 21: ...2500 Red 1 30 270 021 2300 Blue 1 30 270 021 2600 Button Cable SPEC 28 support 24V 0 5A Environ ment Humidity 85 40 C non condensing Operating Temperature 0 55 C without airflow Storage Tempera ture...

Страница 22: ...x20 mm Enclosure Front bezel Die cast aluminum alloy RAL9011 Back housing Die cast aluminum alloy RAL9011 Mounting ARM mounting Pendant and Pedestal VESA mounting Power Input Voltage 24VDC 25 20 Powe...

Страница 23: ...utton 1 Push button RAFI 22 FS Push button 1NC1NO White 1 30 270 021 2200 Black 1 30 270 021 0100 Blue 1 30 270 021 2600 Button Cable SPEC 28 support 24V 0 5A Button cover color RAL 7035 Environ ment...

Страница 24: ...SPC 800 M User Manual 14 1 5 I O Ports Arrangement The arrangement of the I O ports is shown in Figure 1 1 Figure 1 1 Front view and Side view Figure 1 2 Rear view for SPC 800 MLAG SPC 800 MLAP Series...

Страница 25: ...15 SPC 800 M User Manual Chapter 1 General Information Figure 1 3 Rear view for SPC 800 M7AG SPC 800 M7AP Series...

Страница 26: ...SPC 800 M User Manual 16 1 6 Dimensions SPC 815 M BOR DE115W Weight 7 83kg Dimensions W x H x D 402 x 333 x 67mm 15 83 x 13 11 x 2 64 Figure 1 4 SPC 815 M BOR DE115W Dimensions...

Страница 27: ...17 SPC 800 M User Manual Chapter 1 General Information SPC 821 M BOR DE121W Weight 10 63kg Dimensions W x H x D 547 x 420 x 67 mm 21 54 x 16 54 x 2 64 Figure 1 5 SPC 821 M BOR DE121W Dimensions...

Страница 28: ...SPC 800 M User Manual 18...

Страница 29: ...Chapter 2 2 System Setup...

Страница 30: ...manual to make sure all items have been included Figure 2 1 Unpack the Package The following components are included in the scope of delivery of the SPC 800 M device 2 1 1 Accessory BOX 2 1 2 ARM Mou...

Страница 31: ...he device to a support ARM or VESA system using example figures SPC 815 and SPC 821 are the same design and same com ponent for Pendant and Pedestal mounting no additional component is needed And VESA...

Страница 32: ...ews of IO Bracket Note Base Unit Product accessory without a pole mounting The SPC 800 devices M BOR DE1000 series are designed for mount ing with the base cover IO If you install the device with an A...

Страница 33: ...23 SPC 800 M User Manual Chapter 2 System Setup 2 Attach the IO with M5 or M6 x 4pcs screws to the interface of the support pole mount 3 Fasten the OP bracket with cover IO by the screw...

Страница 34: ...the device with M5x 4pcs screws to the IO from back side Make sure that the connection cables whether put into the pole mount Installation Procedure Pendant and Pedestal mounting 1 Loosen the M5 x 4p...

Страница 35: ...pport VESA Mounting Requirement VESA Kit x 1pc VESA Screw x 4pcs Note Base Unit Product accessory without a VESA mounting and Cable Entry The SPC 800 M BOR DE1000 series devices are designed for mount...

Страница 36: ...lit cable entry system KEL ER 10 for rout ing and sealing cables with connectors Cable diameters from 1 to 16 mm and 16 to 35 mm IP65 IP66 3 Split cable entry system KEL ER 24 for rout ing and sealing...

Страница 37: ...Installation Procedure 1 Install VESA ARM to the VESA adapter by M4 x 4pcs screws 2 Fix 2 pcs of M5 screws into upside screw holes icoteck Round cable 4 5 mm 41304 KT 4 bk icoteck Round cable 3 4 mm 4...

Страница 38: ...SPC 800 M User Manual 28 3 Fit into two holes with two screws 4 Fix 2 pcs of M5 screw into the body through the holes downside in the VESA kit...

Страница 39: ...m Setup 5 Arrange the cables through the opening of the cover and fix the cover by M5 x 4pcs screws 6 Fix the cables in the entry frame by 3pcs M5 screws and fix the entry to body by 2pcs M5 screws 7...

Страница 40: ...ally tighten the 4 screws 2 4 SPC 800 M Extension with Operator Controls The following example shows a SPC 800 M device with an Extension Unit SPC 800 M device with operator controls extension can ord...

Страница 41: ...sign has pre hole 1 15 with seven pre hole and USB location 2 21 with ten pre hole and USB location Push Button with Extension Unit Use four Button Extension Unit 15 and 21 base unit operator controls...

Страница 42: ...ens round collar metal front ring momentary 1 30 270 021 2200 RAFIX 22 FS Drucktaster nicht beleuchtbar flache Blende Bund rund Frontring Metall tastend 1 30 270 021 0100 RAFIX 22 FS Pushbutton illumi...

Страница 43: ...nd collar metal front ring momentary 1 30 270 021 0700 RAFIX 22 FS Keylock switch round collar 1 30 255 321 0100 Black 1 30 255 321 0300 Red 1 30 255 321 0400 Yellow 1 30 255 321 0500 Green 1 30 255 3...

Страница 44: ...SPC 800 M User Manual 34 3 Pre hole cut outs 4 Fix the RAFI button assembly of the threaded ring 5 Attach the Button s PCBA with M3 x 4pcs screw to the OP back side...

Страница 45: ...35 SPC 800 M User Manual Chapter 2 System Setup 6 Fasten the OP back side by the screw 7 Install the terminal Board with M3 x 4pcs screws...

Страница 46: ...SPC 800 M User Manual 36...

Страница 47: ...Appendix A A OSD Operating Process...

Страница 48: ...s designed as the HMI Touch glass printing device A 1 1 OSD Button Description icon Indicator Status intelligent Selected option Home Activate the OSD menu Enter confirm the selected option Decreases...

Страница 49: ...is changed before time out or power is turned off before time out TIME OUT 5 6 seconds Can be set in OSD Manager The default definition of input keys is shown as following A 2 1 Menu Start Press home...

Страница 50: ...onfirmation Range 0 100 A higher value will make the picture appear brighter A 2 3 Video Input Select Video Input function by Press Home key Press the Input Selection that corresponds with the video s...

Страница 51: ...ent key HDMI Source Make sure the HDMI connection is enable on the device To do it Press Home key show to OSD Menu Select Video Input Select Input HDMI Press Intelligent key RX Source Make sure the CD...

Страница 52: ...t PIP function by Press Home key and selection that corresponds with the PIP connection mode The size and position of the smaller screen can all be adjusted in PIP function There is limited combinatio...

Страница 53: ...disable touch function to ensure mis touch Off for 60 sec to disable touch function and after 60 seconds the touch function will be enabled automatically Always On default setting of touch function N...

Страница 54: ...e subject to change without notice No part of this publication may be reproduced in any form or by any means such as electronically by photocopying recording or otherwise without prior written permiss...

Отзывы: