T1 PORT VERIFICATION
By placing a physical loopback connection on the T1 port, a valid signal can
be detected by each individual T1 port to verify its operation. Without the fiber
looped, the ALARM LED for looped T1 port will show RED/GREEN indicating
there is a problem at the far end of the fiber transport (In this case the far end
unit is missing) and the STAT LED is RED because the fiber is in LOS. With
the fiber looped, the T1 port will only show a normal GREEN STAT LED.
10/100BASET ETHERNET MATING CONNECTOR PINOUT
The following table lists the pin configuration for the RJ-45 Ethernet connector.
Pin
Signal
1
Tr
2
Transmit -
3
R
4
None
5
None
6
Receive -
7
None
8
None
NOTE
:
MDI/MDIX AutoCross function will automatically transpose the Transmit and Receive lines if required.