Documentation Number 232BSS4 0812 Manual
25
Setup Tutorial
Step 1: Start the software by double clicking the Smart Switch setup icon
on the desktop.
Step 2: Select the serial (COM) port that will be used to configure the
232BSS4 or Check the box to create a configuration file without the
232BSS4 connected.
Step 3: Click Next
Step 4: If you are creating a configuration without a switch connected,
proceed to “Single Unit Main screen.” Otherwise, select the way that
the 232BSS4 will be used. If the 232BSS4 is going to be used with an
intelligent Master device, or if only certain parameters are going to
change, select Single Unit operation. If two 232BSS4 switches will be
used in a back-to back configuration, select Back to Back.
Step 5: Connect the 232BSS4 to the COM port selected. Install the setup
jumper, and power up the 232BSS4. When Next is clicked, the
software reads the current configuration of the connected switch and
displays the Main Screen.
Single Unit Main Screen:
All configuration of the 232BSS4 can be initiated from the Main
Screen. The overall operation of the switch and each port’s parameters
can be individually selected and modified.
NOTE:
All character values specified in the setup software are given
in decimal. For ASCII or Hex equivalents, refer to Appendix A.
File Menu:
From the file menu, a configuration can be saved to disk, loaded from a
disk, or printed to the default Windows printer. This provides an easy
method of configuring multiple switches with the same setup.
Operation Setup:
When selected, the Operation Setup button displays the parameters
associated with the basic operation of the switch. In this screen, the
user can set the switch for Smart Switch Only or Auto Select mode.
The “Set DTR for Commands” check box configures the 232BSS4 to
only accept commands from the Master device if DTR (pin 20) is
raised.
The number of command characters is set through a pull-down menu.
The first 2/3 command characters are also specified in this section.
When the switch is set for Auto Select mode, the Port Time and
Inactivity time must be set. This time is in milliseconds and must be
Содержание B+B SmartWorx 232BSS4
Страница 4: ...ii Documentation Number 232BSS4 2916m...
Страница 8: ...4 Documentation Number 232BSS4 2916m...
Страница 34: ...30 Documentation Number 232BSS4 0812 Manual...
Страница 36: ...A 2 Appendix A Documentation Number 232BSS4 0812Manual 5...
Страница 42: ...B 6 Appendix B Cable Charts Documentation Number 232BSS4 2916 Manual...
Страница 44: ...C 2 Appendix C Documentation Number 232BSS4 0812 Manual...
Страница 45: ...Manual Documentation Number XXXxxx 0812 B 1...