MENU (SCREEN) PAGE #2
NOTE: These commands require that the unit be in REMOTE mode with the serial interface in
control. See screen (menu) page #1 key ‘F2’ bytes 9 & 13.
Figure 9
: Page #2 of the Communication Program
F1, F2 & F8 - N/A (not available)
F3 - Prevents the unit from going to LOCAL mode. This is to be used with rack-mount unit
where the operator requests to go local and the control room wants to lock out the operator.
F4 - Puts the unit in AUTO mode.
F5 - Puts the unit in MANUAL mode.
F6 - Sets switch so that output goes to Antenna. (Unit must be in MANUAL mode).
F7 - Sets switch so that output goes to RF load. (Unit must be in MANUAL mode).
F9 - Sets user defined threshold. This should be a value from 300 to 500 representing 30.0 to
50.0 dBm. When the output level falls below this level an alarm will be generated.
F10 - ‘MORE’ goes to next menu (screen) page.
Copyright 1995.
F1 F2 F3
Remote
F4
Auto
F5
Manual
F6
SWAnt
F7
SWLoad
F8
F9
Thresh
F0
More
ADVANTECH - Advanced Microwave Technologies, Inc.
Address
: 0
Parameters : >00AQSWT0 A0.0O43.1
PAGE - 2 - PROTOCOL: ADV, 9600, E Rev 1.40
Alt-X to exit
Содержание ARMA-C250-CRM
Страница 13: ...ARMA C250 CRM 12 Figure 1 Product Outline redundant system front and rear views...
Страница 14: ...ARMA C250 CRM 13 Figure 2 Waveguide Connections top view side view...
Страница 56: ...ARMA C250 CRM 55 Figure 12 Product Outline single unit...
Страница 57: ...ARMA C250 CRM 56 Figure 13 3 D View of the Redundant System in rack cabinet...
Страница 58: ...ARMA C250 CRM 57 Figure 14 Enlarged 3 D View of the Redundant System in rack cabinet...