UEFI Variables Protection

Password protection of Runtime

Control the NVRAM Runtime Variable protection through System Admin Pass

-

word.

Содержание ARK-7060

Страница 1: ...User Manual ARK 7060 Embedded Box PC ...

Страница 2: ...e contains a hard copy user manual in Chinese for China CCC certifica tion purposes There is an English user manual included as a PDF file on the CD Please disregard the Chinese hard copy user manual if the product is not to be sold and or installed in China ...

Страница 3: ...ernational Inc VIA is a trademark of VIA Technologies Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Cor poration Intel and Pentium are trademarks of Intel Corporation Microsoft Windows is a registered trademark of Microsoft Corp RTL is a trademark of Realtek Semi Conductor Co Ltd ESS is a trademark of ESS Technology Inc UMC is a trademark of United Microelectronics C...

Страница 4: ...defective obtain a return merchandise authori zation RMA number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a completed Repair and Replacement Order Card and a proof of purchase date such as a photocopy of your sales receipt into a shippable container Products returned without a proof of pur chase date are not eligible for warranty ser...

Страница 5: ...ings Cautions and Notes Packing List Before system installation check that the items listed below are included and in good condition If any item does not accord with the list contact your dealer immediately 1 x ARK 7060 Unit 1 x Mounting Kit 1 x User Manual Simplified Chinese 1 x China RoHS Warning Warnings indicate conditions that if not observed can cause personal injury Caution Cautions are inc...

Страница 6: ... x PCIx16 ARK 7060 U4A1 Intel Xeon D 1715TER Up to 128GB 2 2 optional 1 2 Up to 4 4 4 1 1 1 Yes 850W 1 x PCI 1 x PCIex4 1 x PCIx16 Note Memory Storage and operating system bundled by request Part Number Description 1702002600 Power cable 3 pin 183 cm 64 1 in USA type 1702002605 Power cable 3 pin 183 cm 64 1 in EU type 1702031801 Power cable 3 pin 183 cm 64 1 in UK type 1700000237 Power cable 3 pin...

Страница 7: ...The power cord or plug is damaged Liquid has penetrated the equipment The equipment has been exposed to moisture The equipment is malfunctioning or does not operate according to the user manual The equipment has been dropped and damaged The equipment shows obvious signs of breakage 15 Do not leave the equipment in an environment with a storage temperature of below 40 C 40 F or above 85 C 185 F as ...

Страница 8: ...reil n est pas utilisé pendant une longue période débranchez le du sec teur pour ne pas être endommagé par une surtension transitoire 12 Ne jamais verser de liquide dans les ouvertures de ventilation Cela pourrait provoquer un incendie ou un choc électrique 13 N ouvrez jamais l équipement Pour des raisons de sécurité seul le personnel de maintenance qualifié doit ouvrir l équipement 14 Si l une de...

Страница 9: ... installé que dans une zone d accès restreint 21 Au moyen d un cordon d alimentation connecté à une prise de courant avec mise à la terre 22 Ce produit est destiné à être alimenté par un bloc d alimentation homologué UL adapté à une utilisation à Tma 50 degrés C min dont la sortie est conforme à PS2 ou LPS ES1 ou SELV et dont la sortie est nominale 9 36Vdc 16 65 4 16A si besoin d aide supplémentai...

Страница 10: ...ARK 7060 User Manual x ...

Страница 11: ...9 Figure 2 1 Jumper Layout 9 2 2 4 Jumper Settings 9 2 2 5 Bottom Board Jumper List 11 2 2 6 Jumper Locations 12 2 2 7 Jumper Settings 13 2 3 Connectors 15 2 3 1 External I O Locations 15 Figure 2 2 Front I O Connector Diagram 15 Figure 2 3 COM Port Connector 16 Table 2 1 COM Connector Pin Assignments 16 Figure 2 4 Ethernet Connector 17 Table 2 2 CN5 CN6 Ethernet Connector Pin Assignments 17 Table...

Страница 12: ...llation 25 2 4 7 Wide Operating Temperature Support 25 Chapter 3 BIOS Settings 27 3 1 Introduction 28 3 2 Entering the Setup 29 3 2 1 Main Setup 29 3 2 2 Advanced BIOS Features Setup 30 3 2 3 Platform Configuration 45 3 2 4 Socket Configuration 69 3 2 5 Server Management 81 3 2 6 Security 87 3 2 7 Boot 89 3 2 8 Save Exit 90 Appendix A Watchdog Timer Sample Code 91 A 1 EC Watchdog Timer Sample Code...

Страница 13: ...Chapter 1 1 General Introduction This chapter details background information on the ARK 7060 series ...

Страница 14: ...d protects against virus and or data corrup tion ARK 7060 also features an on board baseboard management controller BMC to provide PMI architecture for remote management Built in Intelligent Management Tools Advantech SUSI API and WISE Devi ceOn Advantech SUSI API provides a valuable suite of programmable APIs such as multi level watchdog hardware monitoring system restoration and other user frien...

Страница 15: ...at form Management Interface 2 0 via dedicate LAN VGA and console port 1 x VGA 1 x GbE management port 1 x console port Storage 2 x 2 5 swappable SATAIII HDD Bay with RAID 0 1 and max height 15 mm 0 59 in up to 4 x 2 5 SATAIII HDD Bay by AMK A0042 Expansion Interface 1 x M 2 2230 2280 3052 B Key supporting M 2 2242 3042 with bracket sup port SIM holder 1 x M 2 2230 E key for Wi Fi modules Add on C...

Страница 16: ... for 4 x USB 3 0 ports All ports are High Speed Full Speed and Low Speed capa ble Supports legacy keyboard mouse software BIOS 2 x AMI 512 Mbit EFI Flash BIOS via SPI Dual BIOS Serial Ports 4 x serial ports Supports IRQ Sharing among serial ports under Microsoft Windows OS COM1 COM2 COM3 and COM4 RS232 422 485 Ethernet LAN1 2 support 10 100 1000 Mbps LAN3 4 support 100 1000 10000 Mbps LAN Connecto...

Страница 17: ...60 User Manual Chapter 1 General Introduction 1 4 Mechanical Specifications 1 4 1 Dimensions W x H x D 230 x 205 x 390 mm 9 05 x 8 07 x 15 35 in Figure 1 1 ARK 7060 Mechanical Dimensions Diagram 230 205 390 10 ...

Страница 18: ...ply 850W power supply built in 1 6 Operating Environment Specifications 1 6 1 Operating Temperature With extended peripherals 10 50 C 14 112 F with 0 7m s air flow 1 6 2 Relative Humidity 95 40 C 104 F non condensing 1 6 3 Storage Temperature 40 85 C 40 185 F 1 6 4 Safety CB 62368 UL 62368 CCC BSMI and UKCA 1 6 5 EMC CE FCC Class B CCC BSMI and UKCA ...

Страница 19: ...Chapter 2 2 Hardware Configuration ...

Страница 20: ...e clip To open a jumper remove the clip Sometimes a jumper will have three pins labeled 1 2 and 3 In this case you would connect either pins 1 and 2 or 2 and 3 The jumper settings are schematically depicted in this manual as follows A pair of needle nose pliers may be helpful when working with jumpers If you have any doubts about the best hardware configuration for your application contact your lo...

Страница 21: ...s Figure 2 1 Jumper Layout 2 2 4 Jumper Settings 2 2 4 1 Clear CMOS Setting for JCMOS1 JCMOS1 Clear CMOS Settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2 0 mm 180D M DIP 2000 13 WS Setting Function 1 2 Normal Operation Default 2 3 Clear CMOS ...

Страница 22: ...o Power On 2 3 Power button for Power On Default M 2 E Key SMBus Enable Settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2000 13 WS Setting Function 1 2 Disable M 2 SMBus Channel 2 3 Enable M 2 SMBus Channel Default No Jumper Fail safe Enable Settings Part Number 1600000402 Foot Print SW_4x2P_50_260x315 Description DIP SW SMD 8P SPST P 1 27mm W 5...

Страница 23: ...rint SW_4x2P_50_260x315 Description DIP SW SMD 8P SPST P 1 27 mm W 5 4mm KHS42E Setting Function Switch to Pin 1 2 3 4 OFF Default Switch to Pin 5 6 7 8 ON Table 2 1 Jumper List M2_SEL1 M 2 B Key Select Function Source Between SATA and PCIE M2_SEL2 M 2 B Key Select Function Source Between USB 3 0 and PCIE NGFF_SMBEN1 M 2 B Key SMB Enable CN10 5G Module power switch ...

Страница 24: ...ARK 7060 User Manual 12 2 2 6 Jumper Locations ...

Страница 25: ...EL1 M 2 select function source settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2000 13 WS Setting Function 1 2 Auto detect by card Default 2 3 SATA Floating PCIE M2_SEL2 M 2 select function source settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2000 13 WS Setting Function 1 2 Auto detect by ca...

Страница 26: ... HD_3x1P_79_D Description PIN HEADER 3x1P 2 0mm 180D M DIP 2000 13 WS Setting Function 1 2 Disable M 2 SMBus Channel 2 3 Enable M 2 SMBus Channel Default Power switch Settings Part Number 1653003101 Foot Print HD_3x1P_79_D Description PIN HEADER 3x1P 2 0 mm 180D M DIP 2000 13 WS Setting Function 1 2 Set Vout 3 805V For 5G module support 3 805V 2 3 Set Vout 3 304V Default ...

Страница 27: ...15 ARK 7060 User Manual Chapter 2 Hardware Configuration 2 3 Connectors 2 3 1 External I O Locations Figure 2 2 Front I O Connector Diagram ...

Страница 28: ...interface ports The default setting is RS 232 the mode RS 422 485 of ARK 7060 are supported via BIOS settings Figure 2 3 COM Port Connector Table 2 1 COM Connector Pin Assignments RS 232 RS 422 RS 485 Pin Signal Name Signal Name Signal Name 1 DCD Tx DATA 2 RxD Tx DATA 3 TxD Rx NC 4 DTR Rx NC 5 GND GND GND 6 DSR NC NC 7 RTS NC NC 8 CTS NC NC 9 RI NC NC ...

Страница 29: ...y 10GBASE T controllers provid ing 10Gb s of throughput These Ethernet ports provides a standard RJ 45 jack connector with LED indicators on the front side to show its Active Link status Green LED and Speed status Yellow LED Figure 2 4 Ethernet Connector For LAN1 2 Connector Table 2 2 CN5 CN6 Ethernet Connector Pin Assignments Pin 10 100 1000BaseT Signal Name C1 MDI_LAN_D0_P C2 MDI_LAN_D0_N C3 MDI...

Страница 30: ... sup ports dual functions Soft Power On Off Instant off or Delay 4 Seconds then off and Suspend Figure 2 5 Power ON OFF Button 2 3 1 4 LED Indicators There are four LEDs on the front panel that indicate the system s status HDD LED is for HDD status Figure 2 6 LED Indicators Table 2 3 10G Card LAN1 Ethernet Connector Pin Assignments Pin 10GBaseT Signal Name C1 TRD1 C2 TRD1 C3 TRD2 C4 TRD3 C5 TRD3 C...

Страница 31: ...d a new set of pins for USB 3 0 connectivity Figure 2 7 USB 3 0 Connector 2 3 1 6 BMC Dedicated LAN Connector Figure 2 8 BMC Dedicated LAN Connector Table 2 4 USB 3 0 Connector Pin Assignments Pin Signal Name Pin Signal Name 1 5V 2 USB_data 3 USB_data 4 GND 5 SSRX 6 SSRX 7 GND 8 SSTX 9 SSTX Table 2 5 CN9 BMC Dedicated LAN Connector Pin Assignments Pin 10 100 1000BaseT Signal Name C1 MDI_LAN_D0_P C...

Страница 32: ...ure 2 10 BMC Dedicated VGA Port Table 2 6 COM2 BMC Dedicated COM Port Pin Assignments Pin Signal Name RS232 1 NC 2 RxD 3 TxD 4 NC 5 NC 6 NC 7 NC 8 NC 9 NC Table 2 6 VGA Connector Pin Assignments Pin Signal Name Pin Signal Name 1 Red 2 Green 3 Blue 4 NC 5 GND 6 GND 7 GND 8 GND 9 NC 10 GND 11 NC 12 DDAT 13 H SYNC 14 V SYNC 15 DCLK ...

Страница 33: ...User Manual Chapter 2 Hardware Configuration 2 4 Installation 2 4 1 Remove Top Cover 1 Unscrew the 7 screws on the top cover 2 Slightly move the top cover backward and then lift it up to remove it STEP 1 2 P E T S ...

Страница 34: ...iguration Instruction Using 1 x DIMM install on CN1 or CN3 slot Using 2 x DIMM install on CN1 CN3 slot Using 3 x DIMM is not supported 2 4 3 HDD SSD Installation 1 Unscrew the 2 x screws on the hard drive bay 2 Install HDD SSD with 4 x screws on the HDD SSD tray 3 Push back the hard drive bay into the system and secure it using the same screws ...

Страница 35: ...n Internal SIM Slot 1 Remove top cover 2 4 1 2 Install M 2 B Key module M2B1 with SIM holder with bracket according to the M 2 module form factor and secure in place with screw s 3 Install M 2 E key module with 1 x screw M2E1 4 Replace the top cover and secure it in place with 7 screws ...

Страница 36: ...ll the top rubber on top horizontal bar to secure the graphics card Install the bottom nut according to length of the graphics card 5 Install the graphics card secure it with a screw M5X11L on the bottom nut and connect the cable If the cable is too short slightly pull the cable outward 6 Replace return the 2 horizontal bars on the top of the system 7 Replace the top cover and secure in place with...

Страница 37: ...x screws M4x6L from carton 2 Screw each of the 3 x screws M4x6L on the left and right sides to secure the system horizontally 2 4 7 Wide Operating Temperature Support To make sure the system works well under 0 C 32 F or over 50 C 122 F please ensure your peripherals are i grade These support wide temperature opera tion ...

Страница 38: ...ARK 7060 User Manual 26 ...

Страница 39: ...Chapter 3 3 BIOS Settings ...

Страница 40: ...an modify BIOS settings and control various sys tem features This chapter describes the basic navigation of the ARK 7060 BIOS setup screens AMI s BIOS ROM has a built in Setup program that allows users to modify the basic system configuration This information is stored in flash ROM so it retains the Setup information when the power is turned off ...

Страница 41: ...he Main setup screen by selecting the Main tab There are two Main Setup options They are described in this section The Main BIOS Setup screen is shown below The Main BIOS setup screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured options in blue can The right frame displays the key legend Above the key legend is an area r...

Страница 42: ...can select any item in the left frame of the screen such as CPU Configuration to go to the sub menu for that item Users can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanced BIOS Setup options are described in this section The Advanced BIOS Setup screens are shown below The sub menus are described on the following pages ...

Страница 43: ...31 ARK 7060 User Manual Chapter 3 BIOS Settings 3 2 2 1 Trusted Computing TPM Support Enable or Disable TPM Support Security Device Support Enables or Disables BIOS support for security device ...

Страница 44: ...orm Hierarchy Storage Hierarchy Enable or Disable Storage Hierarchy Endorsement Hierarchy Enable or Disable Endorsement Hierarchy TPM 2 0 UEFI Spec Version Select the TCG2 Spec Version Support TCG_1_2 the Compatible mode for Win8 Win10 TCG_2 Support new TCG2 protocol and event format for Win10 or later Physical Presence Spec Version Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Note so...

Страница 45: ...33 ARK 7060 User Manual Chapter 3 BIOS Settings Power Saving Mode This item allows users to set the board s power saving mode when off ...

Страница 46: ... Port 1 Configuration Set Parameters of Serial Port 1 Serial Port 2 Configuration Set Parameters of Serial Port 2 Serial Port 3 Configuration Set Parameters of Serial Port 3 Serial Port 4Configuration Set Parameters of Serial Port 4 ...

Страница 47: ...35 ARK 7060 User Manual Chapter 3 BIOS Settings ...

Страница 48: ...ode and parameters Temp threshold of high speed Set temperature threshold of high speed Range 0 100 Maximum PWM Duty Set maximum PWM Duty output value Range 0 100 Temp threshold of low speed Set temperature threshold of low speed Range 0 100 Minimum PWM Duty Set minimum PWM Duty output value Range 0 100 Temp threshold of stop FAN Set temperature threshold of stop FAN Range 0 100 ...

Страница 49: ...7 ARK 7060 User Manual Chapter 3 BIOS Settings 3 2 2 3 S5 RTC Wake Settings Wake System From S5 Enable or disable System wake on alarm event Select Fixed Time system will wake on the hr min sec specified ...

Страница 50: ...ARK 7060 User Manual 38 3 2 2 4 UEFI Variables Protection Password protection of Runtime Control the NVRAM Runtime Variable protection through System Admin Pass word ...

Страница 51: ...ser Manual Chapter 3 BIOS Settings 3 2 2 5 Serial Port Console Redirection Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services EMS ...

Страница 52: ... USB Support This supports USB devices with legacy OS such as DOS When choosing AUTO the system will automatically detect USB devices It will enable USB legacy mode when a USB device is plugged in and disable USB legacy mode when no USB device is plugged in ...

Страница 53: ...e Reset Time Out Allows you to select the USB device reset time out value 10 20 30 40sec Device Power Up Delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is take from Hub descriptor Mass Storage Devices Mass storage device emulation type Auto enumerates device according to ...

Страница 54: ...ARK 7060 User Manual 42 Network Stack Enable or Disable UEFI Network Stack 3 2 2 8 NVMe Configuration ...

Страница 55: ...43 ARK 7060 User Manual Chapter 3 BIOS Settings NVMe Configuration Display device information of NVMe E g model name size 3 2 2 9 Tls Auth Configuration ...

Страница 56: ...al 44 Server CA Configuration Configure a server CA Certificate Authority settings Client Cert Configuration Configure Client Cert settings Client cert configuration is unsupported currently 3 2 2 10 All CPU Information ...

Страница 57: ...45 ARK 7060 User Manual Chapter 3 BIOS Settings Display the information of each CPU core 3 2 3 Platform Configuration 3 2 3 1 PCH IO Configuration ...

Страница 58: ... 46 Serial IRQ Mode Configure Serial IRQ Mode State After G3 Specify what state to go to when power is re applied after a power failure G3 state Flash Protection Range Registers FPRR Enable Flash Protection Range Registers ...

Страница 59: ...eer Memory Write Enable Enable Disable Peer Memory Write Compliance Test Mode Enable when using Compliance Load Board LAN1 LAN2 Controller Enable Disable on board LAN1 LAN2 from Intel i210 Controller support Intel X550 Controller Enable Disable on board LAN3 LAN4 from Intel X550 Controller support LAN3 LAN4 are optional by AMO I031 ...

Страница 60: ...ARK 7060 User Manual 48 PCI Express Root Port Configure PCI Express Root Port Settings ASPM PCI Express Active State Power Management settings L1 Substates PCI Express L1 Substates settings ...

Страница 61: ...anual Chapter 3 BIOS Settings PCIe Speed Configure PCIe Speed Auto is equal to Gen2 or Gen3 depending on DTR soft strap SATA Configuration SATA Controller Speed Indicates the maximum speed the SATA controller can support ...

Страница 62: ...ntroller SATA Mode Selection Determine how SATA controllers operate Aggressive LPM support Enables Disables SATA Aggressive Link Power Management This item will appear when AHCI or RAID is selected SATA port 1 2 3 4 Enable disable SATA port SATA port 3 4 are optional ...

Страница 63: ...pter 3 BIOS Settings HDD Unlock If enabled it indicates that the HDD password unlock in the OS is enabled LED Locate If enabled it indicates that the LED SGPIO hardware is attached and ping to locate feature is enabled on the OS ...

Страница 64: ...or pin based debug If pin based debug is enabled but USB overcurrent is not disabled USB DbC does not work USB Overcurrent Lock Select Enabled if Overcurrent functionality is used Enabling this will make xHCI controller consume the Overcurrent mapping data USB2 PHY Sus Well Power Gating Select Enabled to enable SUS Well PG for USB2 PHY This option has no effect on PCH H XHCI Wake On Usb Enable Ena...

Страница 65: ...53 ARK 7060 User Manual Chapter 3 BIOS Settings Security Configuration RTC Memory Lock Enable will lock bytes 38h 3Fh in the lower upper 128 byte bank of RTC RAM ...

Страница 66: ... Enable or Disable the PCH BIOS Lock Enable feature Required to be enabled to ensure SMM protection of flash Force unlock on all GPIO pads If Enabled BIOS will force all GPIO pads to be in unlocked state 3 2 3 2 Sever ME Configuration ...

Страница 67: ... ARK 7060 User Manual Chapter 3 BIOS Settings MCTP Bus Owner 15 8 bus 7 3 device 2 0 function If all zeros sending bus owner is disabled 3 2 3 3 System Event Log System Error Enable Disable setup options ...

Страница 68: ... are masked from OS SW visibility This option is valid only when EMCA is enabled FatalErrDebugHalt DEBUG loop for McBank Fatal error case ONLY Warning Enable this knob only in conjunction with ITP as thread will halt in Fatal error flow Mca Bank Warm Boot Clear Errors Enable Disable Mca Bank Warm Boot Clear Errors CrashLog Feature The feature helps collecting crash data from PMC SSRAM CrashLog On ...

Страница 69: ... EMCA CMCI SMI Threshold Set the threshold of correctable error for signaling CMCI CSMI CSMI Dynamic Disable Enable BIOS disables CSMI when error threshold reached Disabled CSMI always on EMCA MCE SMI Enable Enable Disable EMCA Uncorrected SMI for gen2 Corrected Error eLog Enable Disable Corrected Error eLog Memory Error eLog Enable Disable Memory Error eLog Processor Error eLog Enable Disable Pro...

Страница 70: ...ARK 7060 User Manual 58 WHEA Settings WHEA Support Enable Disable WHEA support WHEA Log Memory Error Enable Disable Whea Log Memory Error ...

Страница 71: ...r 3 BIOS Settings WHEA Log Processor Error Enable Disable Whea Log Processor Error WHEA Log PCI Error Enable Disable Whea Log PCI Error Error Injection Setting WHEA Error Injection Support Enable Disable WHEA Error Injection Support ...

Страница 72: ...ARK 7060 User Manual 60 Memory Error Enabling Memory Error Enable Disable Memory Error Memory Corrected Error Enable Disable Memory Corrected Error Spare Interrupt Spare Interrupt Selection ...

Страница 73: ...61 ARK 7060 User Manual Chapter 3 BIOS Settings IIO Error Enabling ...

Страница 74: ...de Enable Disable System Event Generation when Error Pin is enabled IIO Error Registers Clear Enable Disable Clear IIO Error Registers IIO eDPC Support Enable Disable IIO eDPC Support IIO Coherent Interface Error Enable Disable IIO Coherent Interface Error IIO IRP0 protocol parity error Enable or disable Coherent Interface protocol IIO parity error reporting IIO IRP0 protocol qt overflow underflow...

Страница 75: ...orting IIO Misc Error Enable Disable IIO Misc Error IIO Vtd Error Enable Disable IIO Vtd Error IIO Dma Error Enable Disable IIO Dma Error IIO Dmi Error Enable Disable IIO Dmi Error PCIE Error Enable Disable PCIE Error IIO PCIE Additional Corrected Error Enable Disable IIO PCIE Additional Corrected Error IIO PCIE Additional Uncorrected Error Enable Disable IIO PCIE Additional Uncorrected Error IIO ...

Страница 76: ...ARK 7060 User Manual 64 PCIe Error Enabling ...

Страница 77: ...orrected Error Limit Set the maximum number of corrected errors before corrected error reporting is disabled for a device PCIE AER Corrected Errors Enable Disable PCIE AER Corrected Errors PCIE AER NonFatal Error Enable Disable PCIE AER NonFatal Error PCIE AER Fatal Error Enable Disable PCIE AER Fatal Error PCIE AER Advisory Nonfatal Error Enable Disable PCIE AER Advisory Nonfatal Error PCIE Unsup...

Страница 78: ...ds the threshold Error Threshold Gen3 4 Set the error threshold for Gen3 and Gen4 speeds An event is triggered when the error count exceeds the threshold Gen3 4 Re Equalization Enable or disable Gen3 and Gen4 re equalization Applies only when operat ing at Gen2 or Gen4 speeds When an event is triggered equalization is re run Gen2 Link Degradation Enable or disable Gen2 link degradation Applies onl...

Страница 79: ...60 User Manual Chapter 3 BIOS Settings Error Control Setting Latch First Corrected Error in KTI Enable or disable latch first corrected error in KTI Patrol Scrub Error Reporting Patrol Scrub Error type selection ...

Страница 80: ...ing Software SRAM Enable or Disable Software SRAM Enable will allocate 1 way of LLC if Cache Configuration subregion is available it will allocate based on the subregion Data Streams Optimizer Enable or Disable Data Streams Optimizer DSO Enable will utilize DSO Sub ...

Страница 81: ...ings that overlap between the two TCC Error Log Enable or Disable TCC Error Log Enable will record errors from TCC flow in memory Wake System From S5 Enable or disable System wake on alarm event Select Fixed Time system will wake on the hr min sec specified 3 2 4 Socket Configuration 3 2 4 1 Processor Configuration ...

Страница 82: ...ARK 7060 User Manual 70 Hyper Threading Enable or Disable Hyper Threading Technology Check CPU BIST Result Enable Disable BIST Built in Self Test on reset 3 2 4 2 Memory Configuration ...

Страница 83: ...ter 3 BIOS Settings Memory Frequency Maximum Memory Frequency Selections in Mhz If Enforce POR is disabled user will be able to run at higher frequencies than the memory support limited by processor support Do not select Reserved ...

Страница 84: ...al 72 3 2 4 3 IIO Configuration PCIe Train by BIOS Assume IIO is strapped for Wait for BIOS because straps are unreliable in A 0 Silicon NTB Link Train by BIOS This knob enables or disables the BIOS to train the NTB link ...

Страница 85: ...is option enables disables the ASPM support for all downstream devices Snoop Response Hold Off Sets Snoop Response Hold Off value 256 cycles as Default PCIe LTR Support This option can disable Latency Tolerance Reporting support in all PCIe root ports Auto keeps hardware default PCIe Extended Tag Support This option can disable 8 bit Tag support in all PCIe root ports Auto keeps hardware default P...

Страница 86: ...r Manual 74 IIO Global Performance Tuning Performance Tuning Mode Select IIO performance tuning mode where Safe mode contains the default HW state and Performance Enable Mode has the recommended perfor mance values ...

Страница 87: ...75 ARK 7060 User Manual Chapter 3 BIOS Settings 3 2 4 4 Advanced Power Management Configuration CPU P State Control ...

Страница 88: ...lect allows user to choose from up to two additional base fre quency conditions Activate SST BF This Option allows SST BF to be enabled EIST PSD Function Choose HW_ALL SW_ALL in _PSD return Boot performance mode Select the performance state that the BIOS will set before OS hand off Energy Efficient Turbo Energy Efficient Turbo Disable MSR 0x1FC 19 Turbo Mode Enable Disable processor Turbo Mode req...

Страница 89: ...remote socket frequency is allowed to be Also impacts rate at which frequency drops when feature disengages Perf P Limit Clip Maximum value the floor is allowed to be set to for perf P limit Perf P Limit Threshold Uncore frequency threshold above which this socket will trigger the feature and start trying to raise frequency of other sockets Perf P Limit Enable Disable Performance P Limit ...

Страница 90: ...ARK 7060 User Manual 78 CPU C State Control Enable Monitor MWAIT Allows Monitor and MWAIT instructions CPU C1 auto demotion Allows CPU to automatically demote to C1 Takes effect after reboot ...

Страница 91: ... CPU to automatically undemote from C1 Takes effect after reboot CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Enhanced Halt State C1E Core C1E auto promotion Control Takes effect after reboot OS ACPI Cx Report CC3 CC6 to OS ACPI C2 or ACPI C3 Package C State Control ...

Страница 92: ...ing this mode will prevent PkgC6 as register access fabric is prevented from going into idle C2C3TT Default 0 means AUTO C2 to C3 Transition Timer PPDN_INIT 1 10 1 74 Bit 11 0 Dynamic L1 PCU_MISC_CONFIG Bit 21 dynamic L1 enable PKG C state Lat Neg MSR 1FCh Bit 30 PCH_NEG_DISABLE LTR IIO Input MSR 1FCh Bit 29 LTR_IIO_DISABLE Disable Ignore IIO LTR input ...

Страница 93: ... Not avail able if FRB 2 Timer is disabled OS Watchdog Timer If enabled starts a BIOS timer which can only be shut off by Management Soft ware after the OS loads Helps determine that the OS successfully loaded or fol lows the OS Boot Watchdog Timer policy OS Wtd Timer Timeout Enter the value Between 1 to 30 min for OS Boot Watchdog Timer Expiration Not available if OS Boot Watchdog Timer is disabl...

Страница 94: ...ARK 7060 User Manual 82 3 2 5 1 System Event Log SEL Components Enable Disable all features of system event logging during boot Erase SEL Choose options for erasing SEL ...

Страница 95: ...Chapter 3 BIOS Settings When SEL is Full Choose options for reactions to a full SEL Log EFI Status Codes Disable the logging of EFI status codes or log only error codes or only progress codes or both 3 2 5 2 BMC Self Test Log ...

Страница 96: ...ARK 7060 User Manual 84 Erase Log Erase log options When Log is Full Select the action to be taken when log is full 3 2 5 3 BMC Network Configuration ...

Страница 97: ...urce Select to configure LAN channel parameters statically or dynamically by BMC Unspecified option will not modify any BMC network parameters during BIOS phase 3 2 5 4 View System Event Log If any event logs occur during boot up the event logs will be display at this page ...

Страница 98: ...ARK 7060 User Manual 86 3 2 5 5 BMC User Settings Add User Add user information Delete User Delete user information Change User Settings Allow change User settings ...

Страница 99: ...87 ARK 7060 User Manual Chapter 3 BIOS Settings 3 2 6 Security Administrator Password Set Administrator Password User Password Set User Password ...

Страница 100: ...ecure Boot Secure Boot feature is Active if Secure Boot is Enabled Platform Key PK is enrolled and the System is in User mode The mode change requires plat form reset Secure Boot Mode Secure Boot mode options Standard or Custom ...

Страница 101: ...t Setup Prompt Timeout Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option Display and select boot devices ...

Страница 102: ...e changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User De...

Страница 103: ...Appendix A A Watchdog Timer Sample Code ...

Страница 104: ...d_Port mov al 89h Write EC HW ram out dx al mov dx EC_Data_Port mov al 5Fh Watchdog reset delay time low byte 5Eh is high byte index Timebase 100ms out dx al mov dx EC_Data_Port mov al 64h Set 10 seconds delay time out dx al mov dx EC_Command_Port mov al 89h Write EC HW ram out dx al mov dx EC_Data_Port mov al 57h Watch dog event flag out dx al mov dx EC_Data_Port mov al 04h Reset event out dx al ...

Страница 105: ...93 ARK 7060 User Manual Appendix A Watchdog Timer Sample Code ...

Страница 106: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion from the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2022 ...