background image

11

AiMC-2000 User Manual

Chapter 2

G

eneral

Information

2.3.6

RJ45+USB2.0+USB3.0 stack connector (LAN1_USB12)

 

2.3.7

HD Analog Audio Interface (AUDIO1)

 

R8

MDI_3+

R9

MDI_3-

U11

+5V_USB

U12

USB_D2-

U13

U14

GND

U21

+5V_USB

U22

USB_D3-

U23

U24

GND

Pin

Signal

Pin

Signal

R2

MDI_0+

R3

MDI_0-

R4

MDI_1+

R5

MDI_1-

R6

MDI_2+

R7

MDI_2-

R8

MDI_3+

R9

MDI_3-

U11

+5V_USB

U12

USB_D1-

U13

U14

GND

U21

+5V_USB

U22

USB_D0-

U23

U24

GND

U25

USB3_RX0-

U26

U

U27

GND

U28

USB3_TX0-

U29

U

Pin

Signal

1

LINE IN

2

LINE  OUT

Содержание AiMC-2000

Страница 1: ...User Manual AiMC 2000 Fanless Embedded Micro Computer...

Страница 2: ...l ii Attention This package contains a hard copy user manual in Chinese for China CCC certification Please disregard the printed Chinese copy of the user manual if the product is not to be sold and or...

Страница 3: ...rnational Inc VIA is a trademark of VIA Technologies Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Cor poration Intel and Pentium are trademarks of Intel Corporation Mic...

Страница 4: ...messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as def...

Страница 5: ...hments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages Warnings Cautions and Notes This pro...

Страница 6: ...wer cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the user s ma...

Страница 7: ...posants lectroniques sensibles peu vent tre endommag s par les surtensions soudaines The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER...

Страница 8: ...AiMC 2000 User Manual viii...

Страница 9: ...r SW_422_1 8 Table 2 4 RS 485 422 Terminal Resistor Jumper SW_422_1 8 2 1 6 JOBS1 JWDT1 OBS Beep and Watchdog Timer Output 8 Table 2 5 JOBS1 JWDT1 OBS Beep and Watchdog Timer Output 8 2 2 AiMC 2000 I...

Страница 10: ...2 6 Save and Exit 38 Appendix A Programming the Watchdog Timer 39 A 1 Programming the Watchdog Timer 40 A 1 1 Watchdog Timer Overview 40 A 1 2 Programming the Watchdog Timer 40 Table A 1 Watchdog Time...

Страница 11: ...Chapter 1 1 General Introduction This chapter gives background information on AiMC 2000...

Страница 12: ...gement capabilities for remote monitor ing and control self diagnosis and correction and automatically sends alerts by email Acronis executes backup and storage to save valuable data if the system enc...

Страница 13: ...rate of 500 MB s Interface 2 x RJ45 1 3 4 Power Requirement Power Input Voltage DC 12V Power Adapter AC to DC DC12 V 5A 60W with Phoenix connector 1 4 Environmental Specifications Operating temperatu...

Страница 14: ...AiMC 2000 User Manual 4 1 5 Mechanical Specifications 1 5 1 AiMC 2000 Dimensions Figure 1 1 AiMC 2000 mechanical dimension drawing Unit mm...

Страница 15: ...Chapter 2 2 General Information...

Страница 16: ...connect them To close or turn ON a jumper connect the pins with the clip To open or turn OFF a jumper simply remove the clip Some jumpers comprise a set of three pins labeled 1 2 and 3 With these jum...

Страница 17: ...M1 The default setting is RS 232 Table 2 2 COM1 RS 232 422 485 Mode Selector JSETCOM1 Function Setting Set COM1 as RS 232 default Set COM1 as RS 422 Set COM1 as RS 485 Table 2 3 COM1 RS 232 422 485 Mo...

Страница 18: ...Terminal Resistor Jumper SW_422_1 Function Settings Default Add RS 485 terminator Add RS 422 terminator Table 2 5 JOBS1 JWDT1 OBS Beep and Watchdog Timer Output Closed Pins Result 2 3 Watchdog reset...

Страница 19: ...Power Switch USB3 0 USB2 0 LAN1 USB2 0 USB2 0 LAN2 4 USB2 0 HDMI PS 2 KB MS Remote Power On Off DC in RS 232 2 VGA RS 232 422 485 COM1 RS 232 3 RS 232 4 RS 232 5 RS 232 6 Pin Signal 1 GND 2 12V_DCIN...

Страница 20: ...2 stack connector LAN2_USB34 Pin Signal 1 Keyboard DATA 2 Mouse DATA 3 GND 5 5V 6 Keyboard CLK 8 Mouse CLK Pin Signal Pin Signal 1 RED 2 GREEN 3 BLUE 4 NC 5 GND 6 RED GND 7 GREEN GND 8 BLUE GND 9 5V 1...

Страница 21: ...MDI_3 U11 5V_USB U12 USB_D2 U13 USB_D2 U14 GND U21 5V_USB U22 USB_D3 U23 USB_D3 U24 GND Pin Signal Pin Signal R2 MDI_0 R3 MDI_0 R4 MDI_1 R5 MDI_1 R6 MDI_2 R7 MDI_2 R8 MDI_3 R9 MDI_3 U11 5V_USB U12 US...

Страница 22: ...l U11 5V_USB U12 USB_D6 U13 USB_D6 U14 GND U21 5V_USB U22 USB_D5 U23 USB_D5 U24 GND U31 5V_USB U32 USB_D7 U33 USB_D7 U34 GND U41 5V_USB U42 USB_D8 U43 USB_D8 U44 GND RS 232 RS 422 RS 485 Pin Signal 1...

Страница 23: ...13 AiMC 2000 User Manual Chapter 2 General Information 2 3 10 Remote Power on off connector Pin Signal 1 Power Button 2 GND...

Страница 24: ...AiMC 2000 User Manual 14 2 4 Installation 2 4 1 Memory mSATA mini PCIe Device Installation 1 Remove bottom cover and HDD tray...

Страница 25: ...15 AiMC 2000 User Manual Chapter 2 General Information 2 Install memory mSATA mini PCIe device 3 Install bottom cover and HDD tray Install mini PCIe Install memory Install memory Install mSATA...

Страница 26: ...AiMC 2000 User Manual 16 2 4 2 2 5 HDD Installation 1 Remove bottom cover and HDD tray...

Страница 27: ...17 AiMC 2000 User Manual Chapter 2 General Information 2 Install HDD to HDD tray 3 Install bottom cover and HDD tray...

Страница 28: ...AiMC 2000 User Manual 18...

Страница 29: ...Chapter 3 3 BIOS Operation...

Страница 30: ...em features The CMOS Setup Utility saves the configuration in the CMOS RAM of the mother board When the system power is turned off the battery on the board supplies the necessary power to preserve the...

Страница 31: ...s the options displayed in blue can be The right frame also displays the key legend The area above the key legend is reserved for text messages When an option is selected in the left frame the display...

Страница 32: ...lect any item in the left frame of the screen such as CPU Configuration to access the submenu for that item Select an Advanced BIOS Setup option by highlighting the text using the Arrow keys All Advan...

Страница 33: ...I Settings Enable ACPI Auto Configuration This item allows users to enable or disable ACPI auto configuration Enable Hibernation This item allows users to enable or disable hibernation Lock Legacy Res...

Страница 34: ...erature threshold When the system CPU reaches the threshold temperature a buzzer will emit a warning alert Wake On Ring This item allows users to enable or disable Wake On Ring functionality RS 485 AU...

Страница 35: ...MC 2000 User Manual Chapter 3 BIOS Operation 3 2 2 3 S5 RTC Wake Settings Wake System From S5 This item allows users to enable or disable system wake on alarm event 3 2 2 4 Serial Port Console Redirec...

Страница 36: ...ximum This item allows users to enable or disable the ability to limit the CPUID maxi mum Execute Disable Bit This item allows users to enable or disable the Execute Disable Bit function Intel Virtual...

Страница 37: ...000 User Manual Chapter 3 BIOS Operation This page shows the CPU information 3 2 2 6 PPM Configuration EIST To enable or disable Intel SpeedStep CPU C state Report To enable or disable CPU C state rep...

Страница 38: ...item allows users to set Port 1 or 2 to have ODD functionality SATA Mode This item allows users to select the mode for SATA controller s Serial ATA Port 1 This item allows users to enable or disable...

Страница 39: ...h Precision Timer This item allows users to enable or disable the high precision timer PCI Express Dynamic Clock Gating This item allows users to enable or disable the PCI Express Dynamic Clock Gat in...

Страница 40: ...INT19 Trap Response This item allows users to set the BIOS reaction to INT19 trapping by Option ROM Immediate execute the trap right away postponed execute the trap during legacy boot Boot Options Fil...

Страница 41: ...ort This item allows users to enable or disable the USB mass storage driver USB Transfer Timeouts This item allows users to determine the timeout values for control bulk and interrupt transfers Device...

Страница 42: ...enable or disable TXE firmware updates TXE EOP Message This item allows users to send EOP messages before entering the OS Intel AT This item allows users to enable or disable the BIOS AT code from run...

Страница 43: ...item allows users to enable or disable the LAN 1 controller LAN 1 PXE OpROM This item allows users to enable or disable the LAN 1 option ROM LAN 2 controller This item allows users to enable or disabl...

Страница 44: ...er Manual 34 LCD Control Primary IGFX Boot Display VBIOS Default This item allows users to select the video device activated during POST Sec ondary boot display options are presented according to user...

Страница 45: ...35 AiMC 2000 User Manual Chapter 3 BIOS Operation Audio Configuration Audio Controller This item allows users to enable or disable the audio controller USB Configuration...

Страница 46: ...ers to enable or disable USB 2 0 EHCI support 3 2 4 Security Select the Security tab from the AiMC 2000 BIOS Setup Utility main setup menu All Security options such as password protection and virus pr...

Страница 47: ...should wait for a setup activation key Bootup NumLock State This item allows users to select the power on state for Numlock Quiet Boot If this item is set to Disabled the BIOS displays standard POST...

Страница 48: ...anges This item allows users to save changes to all options Discard Changes This item allows users to discard changes to all options Restore Defaults This item allows users to restore load the default...

Страница 49: ...Appendix A A Programming the Watchdog Timer...

Страница 50: ...ler and facilitates the following user programmable functions Can be enabled and disabled via a user program The timer interval can be set as 1 to 255 seconds or 1 to 255 minutes Generates an interrup...

Страница 51: ...000 User Manual Appendix A Programming the Watchdog Timer Select a register for the watchdog timer Enable the function of the watchdog timer Use the function of the watchdog timer Unlock NCT6106D Lock...

Страница 52: ...stop timer default 01 FF hex The timer value in seconds or min utes depends on the value set in Register F5 hex This value determines how long the watch dog timer waits for the strobe before generati...

Страница 53: ...ut dx al Dec dx enable the watchdog timer function Mov al 30h Out dx al Inc dx Mov al 01h Out dx al Dec dx set the unit of measurement as seconds Mov al 0f0h Out dx al Inc dx In al dx And al not 08h O...

Страница 54: ...urement as minutes Mov al 0f0h Out dx al Inc dx In al dx Or al 08h Out dx al Dec dx set the timeout interval as 5 minutes and start counting Mov al 0f1h Out dx al Inc dx Mov al 5 Out dx al Dec dx lock...

Страница 55: ...dx al Dec dx lock NCT6106D Mov al 0aah Out dx al 4 Enable the watchdog timer to be reset using a keyboard Mov dx 2eh unlock NCT6106D Mov al 87h Out dx al Out dx al Mov al 07h select the watchdog time...

Страница 56: ...Out dx al Out dx al Mov al 07h select the watchdog timer registers Out dx al Inc dx Mov al 08h Out dx al Dec dx enable the watchdog timer function Mov al 30h Out dx al Inc dx Mov al 01h Out dx al Dec...

Страница 57: ...47 AiMC 2000 User Manual Appendix A Programming the Watchdog Timer...

Страница 58: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...