41

AIMB-706 User Manual

C

ha

pte

r 3
BIO

S O

pe

ra

tio

n

CPU Warning Temperature

Use this item to set the CPU warning temperature. When the system reaches

the warning temperature, the speaker will beep.

ACPI Shutdown Temperature

Use this item to set the ACPI shutdown temperature. When the system reaches

the shutdown temperature, it will be automatically shut down by ACPI OS to pro

-

tect the system from overheat damage.

CPUFAN1 Smartfan Setting

"Enable or Disable" CPUFAN1 Mode to SMART FAN setting.

SYSFAN1/SYSFAN3 Smartfan Setting

"Enable or Disable" SYSFAN1/SYSFAN3 Mode to SMART FAN setting.

SYSFAN2 Smartfan Setting

"Enable or Disable" SYSFAN2 Mode to SMART FAN setting.

3.2.2.10

Second Super IO Configuration

Figure 3.17 Second Super IO Configuration

AIMB-706 G2 sku supports 2nd super IO for COM 3~6. This page of BIOS menu is to

set respective serial port configuration. 

Содержание AIMB-706

Страница 1: ...User Manual AIMB 706 LGA1151 Intel CoreTM i7 i5 i3 ATX with Dual Display SATA 3 0 USB 3 1 and DDR4...

Страница 2: ...sion of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the r...

Страница 3: ...aximum performance from your products So if you run into technical difficulties we are here to help For the most frequently asked questions you can easily find answers in your product documentation Th...

Страница 4: ...adio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this device in a residential area is...

Страница 5: ...and any helpful information readily available 3 If your product is diagnosed as defective obtain an return merchandise authori zation RMA number from your dealer This allows us to process your return...

Страница 6: ...AIMB 706 User Manual vi Order Information Part Number Chipset Display COM GbE LAN AIMB 706G2 00A1 H310 VGA DVI 6 2 AIMB 706VG 00A1 H310 VGA 2 1...

Страница 7: ...put and OBS alarm JWDT1 JOBS1 9 1 8 4 ATX AT mode selection PSON1 10 Table 1 5 ATX AT mode selection PSON1 10 1 8 5 USB power source switch between 5V and 5V_DUAL for rear USB ports JUSB_1 and onboard...

Страница 8: ...r SMBUS1 26 Chapter 3 BIOS Operation 27 3 1 Introduction 28 Figure 3 1 Main setup screen 28 3 2 Entering BIOS Setup 29 3 2 1 Main Menu 29 Figure 3 2 Main setup screen 29 3 2 2 Advanced BIOS Features S...

Страница 9: ...61 Figure 3 42Security 61 3 2 5 Boot 62 Figure 3 43Boot 62 3 2 6 Save Exit 63 Figure 3 44Save Exit 63 Chapter 4 Chipset Software Installation Utility 65 4 1 Before You Begin 66 4 2 Introduction 66 4 3...

Страница 10: ...Lock JFP3 89 Table B 14 Power LED and Keyboard Lock JFP3 89 B 12 External Speaker Connector JFP2 89 Table B 15 External Speaker Connector JFP2 89 B 13 HDD LED Connector JFP2 90 Table B 16 HDD LED Con...

Страница 11: ...Chapter 1 1 Hardware Configuration...

Страница 12: ...ities and high speed I O peripheral connectivity The AIMB 706 also adopts Advantech s unique patented Sleep Mode Control Circuit for AT Power Mode With all the excellent features and outstanding perfo...

Страница 13: ...header 1 internal Type A LPC One LPC connector to support optional Advantech LPC modules such as PCA TPM 00B1E PCA COM232 00A1E etc GPIO AIMB 706 supports 8 bit GPIO from super I O for general purpos...

Страница 14: ...as hard disk drives and a keyboard In addition the board has a number of jumpers that are used to configure your system for your application The tables below list the function of each of the jumpers a...

Страница 15: ...N1 SYSFAN3 System fan connector 4 pin JFP3 Keyboard lock and power LED Suspend fast flash ATX AT System on on ATX AT System off off ATX AT JFP2 External speaker HDD LED connector SMBus connector JFP1...

Страница 16: ...USB2H1 AUDIO1 AUDIO2 LAN2 USB2C1 LAN1 USB3C1 KBMS1 VGA1 DVI1 COMD1 COMD2 SYSFAN1 SYSFAN3 VOLT1 EATXPWR1 PSON1 SPI_CN1 GPIO1 LPT1 SMBUS1 JCASE1 COM4 COM5 COM6 LPC1 JT1 JR1 JWDT1 JOBS1 JFP3 JFP1 JFP2 C...

Страница 17: ...B PCIe x16 Gen 3 0 PCIex1 ITE IT8896 PCIe to PCI Bridge PCIex1 Super I O Nuvoton NCT6776D 2nd Super I O Nuvoton NCT5114D LPC Conn LPC 5 PCI Slot 3 RS 232 Header 2 RS 232 Rear PS 2 KB MS H W Monitor W...

Страница 18: ...rk with the hardware Do not make connections while the power is on Sensitive electronic components can be damaged by sud den power surges Only experienced electronics personnel should open the PC chas...

Страница 19: ...IMB 706 will recover from a software failure or an EMI problem The JWDT1 jumper settings control the outcome of what the computer will do in the event the watchdog timer is tripped The 2 pin OBS alarm...

Страница 20: ...upport wake up from S3 via keyboard or mouse Table 1 5 ATX AT mode selection PSON1 Function Jumper Setting AT mode ATX mode default setting 1 2 closed 1 2 3 2 3 closed 1 2 3 Table 1 6 USB power source...

Страница 21: ...22 485 termination resistor JT1 JR1 To stabilize communications JT1 and JR1 use enable or disable 120 ohm of termina tion resistor at board side for COM3 RS 422 485 mode to match impedance depend ing...

Страница 22: ...DIMMs and does NOT support regis tered DIMMs RDIMMs 1 10 Memory Installation Procedures To install DIMMs first make sure the two handles of the DIMM socket are in the open position i e The handles lea...

Страница 23: ...Chapter 2 2 Connecting Peripherals...

Страница 24: ...d in the chassis If you have a number of cards installed you may need to par tially remove a card to make all the connections 2 2 Parallel Port LPT1 The parallel port is normally used to connect the m...

Страница 25: ...ent 1000Base T operation VG sku provides single GbE LAN only The AIMB 706 provides 9 x USB ports USB 2C1 USB 2A1 and USB 2H1 are USB 2 0 ports supporting transmission rates up to 480 Mbps USB3 C1 and...

Страница 26: ...s two on the rear panel and four onboard COM3 can be configured as RS 232 422 485 by jumper settings see Chapter 1 and selecting the correct device mode for RS 485 under BIOS if necessary see Chapter...

Страница 27: ...oard and Mouse Connector KBMS1 KBMS2 Two on board 6 pin mini DIN connectors KBMS1 provide connection to PS 2 key board and mouse A 6 pin header KBMS2 on the motherboard is for an optional PS 2 keyboar...

Страница 28: ...SYSFAN1 SYSFAN3 If a fan is used this connector supports cooling fans that draw up to 500 mA 6 W 2 8 Front Panel Connector JFP1 JFP2 JFP3 There are several external switches and LEDs to monitor and co...

Страница 29: ...the HDD is active 2 8 4 SMBus Connector JFP2 pins 8 11 AIMB 706 conditionally supports Advantech s SAB 2000 module for providing infor mation about the system fan speed and system temperature When ins...

Страница 30: ...dio devices like speakers or headphones Mic In can be connected to a microphone 2 10 8 pin Alarm Board Connector VOLT1 VOLT1 connects to the alarm board on the Advantech chassis The alarm board gives...

Страница 31: ...en sensor The buzzer on the motherboard sounds if the case is opened unexpectedly The default function is disabled and pins 1 2 is bridged by a jumper cap 2 12 Front Panel LAN Indicator Connector LANL...

Страница 32: ...6 User Manual 22 2 13 Serial ATA Interface SATA0 SATA3 AIMB 706 features four high performance serial ATA 3 0 interfaces up to 600 MB s with long thin easy to run SATA cables LANLED1 SATA0 SATA1 SATA2...

Страница 33: ...s 2 14 PCI Slot PCI1 PCI5 The AIMB 706 provides five 32 bit 33 MHz PCI slots 2 15 PCIe x16 Expansion Slot PCIE1 The AIMB 706 provides a PCIe x16 slot for users to install an add on peripheral card for...

Страница 34: ...iliary 4 pin Power Connector ATX12V1 To ensure that enough power is supplied to the CPU one auxiliary 4 pin power con nector is available on the AIMB 706 ATX12V1 must be used to provide sufficient 12...

Страница 35: ...as corrupted and can t be powered up booted up 2 19 Low Pin Count Connector LPC1 LPC connector on AIMB 706 is reserved for optional Advantech LPC modules SPI_CN1 Table 2 3 Advantech LPC Module List P...

Страница 36: ...AIMB 706 User Manual 26 2 20 GPIO Connector GPIO1 2 21 SMBus Connector SMBUS1 GPIO1 SMBUS1...

Страница 37: ...Chapter 3 3 BIOS Operation...

Страница 38: ...er of menus for making changes and turning specific features on or off This chapter describes the basic nav igation of the AIMB 706 setup screens Figure 3 1 Main setup screen AMI s BIOS ROM has a buil...

Страница 39: ...hen an option is selected in the left frame it is highlighted in white Often a text message will accom pany it 3 2 1 Main Menu When users first enter the BIOS Setup Utility they enter the Main setup s...

Страница 40: ...n the left frame of the screen such as CPU configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanced BIOS Set...

Страница 41: ...1 Platform Misc Configuration Figure 3 4 Platform Misc Configuration Platform Misc Configuration Native PCIE Enable PCI Express Native Support Enable Disable Native ASPM On enable OS will control the...

Страница 42: ...he lines are fetched into a 128 byte sector regardless of whether the additional cache line has been requested or not You may choose to Enable or Disable it Intel Virtualization Technology This featur...

Страница 43: ...3 Power Performance Figure 3 6 Power Performance Boot Performance Select the performance state that the BIOS will set before OS handoff Intel Speedstep Allows more than two frequency ranges to be supp...

Страница 44: ...06 User Manual 34 3 2 2 4 PCH FW Configuration Figure 3 7 PCH FW Configuration PCH FW Version PCH FW page shows Intel ME FW information Firmware Update Configuration Figure 3 8 Firmware Update Configu...

Страница 45: ...E FW Image Re flash Enable or Disable ME firmware image re flash function 3 2 2 5 Trusted Computing Figure 3 9 TPM Settings TPM Support Enable or Disable TPM Support You can purchase Advantech LPC TPM...

Страница 46: ...e Hibernation Enable or Disable Hibernation OS S4 Sleep State This option may not be applied in some OS ACPI Sleep State Auto or S1 only or S3 only ACPI Sleep State Lock Legacy Resources Enable or Dis...

Страница 47: ...37 AIMB 706 User Manual Chapter 3 BIOS Operation 3 2 2 7 SMART Settings Figure 3 11 SMART Settings SMART Self Test Enable or Disable SMART Self Test on all HDDs during POST...

Страница 48: ...AIMB 706 User Manual 38 3 2 2 8 Super IO Configuration Figure 3 12 Super IO Configuration Figure 3 13 Serial Port 1 Configuration...

Страница 49: ...39 AIMB 706 User Manual Chapter 3 BIOS Operation Figure 3 14 Serial Port 2 Configuration Figure 3 15 Parallel Port Configuration...

Страница 50: ...ngs Serial port 2 could be selected as Standard serial port mode or IrDA Active pulse 1 6 uS Parallel Port Configuration Parallel Port Enable or Disable Parallel Port Change Settings Select an optimal...

Страница 51: ...automatically shut down by ACPI OS to pro tect the system from overheat damage CPUFAN1 Smartfan Setting Enable or Disable CPUFAN1 Mode to SMART FAN setting SYSFAN1 SYSFAN3 Smartfan Setting Enable or...

Страница 52: ...rial Port 3 Change Settings Select an optimal setting for serial port 3 Device Mode When serial port 3 COM3 is set to RS 485 mode via jumper JSETCOM3 this item should be selected as RS 485 Half Duplex...

Страница 53: ...43 AIMB 706 User Manual Chapter 3 BIOS Operation Figure 3 19 Serial Port 4 Configuration Figure 3 20 Serial Port 5 Configuration...

Страница 54: ...ort 4 Change Settings Select an optimal setting for serial port 4 Serial Port 5 configuration Serial Port Enable or Disable Serial Port 5 Change Settings Select an optimal setting for serial port 5 Se...

Страница 55: ...Manual Chapter 3 BIOS Operation 3 2 2 11 S5 RTC Wake Settings Figure 3 22 S5 RTC Wake Settings Wake system with Fixed Time Enable or Disable System wake on alarm event The system will wake on the hr m...

Страница 56: ...AIMB 706 User Manual 46 3 2 2 12 Serial Port Console Redirection Figure 3 23 Serial Port Console Redirection Figure 3 24 Legacy Console Redirection Settings...

Страница 57: ...irection Legacy Console Redirection Settings Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages Serial Port for Out of Band Management Windows Emergency Manage ment servic...

Страница 58: ...driver USB Mass Storage Driver Support Enable or Disable USB Mass Storage driver support USB transfer time out Allows you to select the USB transfer time out value 1 5 10 20sec Device reset time out...

Страница 59: ...onfiguration Compatibility Support Module Configuration CSM Support Enable or Disable CSM Support The default setting is disabled If your graphic card does not support UEFI mode make sure to select En...

Страница 60: ...AIMB 706 User Manual 50 3 2 2 16 Network Stack Configuration Figure 3 28 Network Stack Configuration Network Stack Enable or Disable UEFI Network Stack...

Страница 61: ...6 User Manual Chapter 3 BIOS Operation 3 2 3 Chipset Figure 3 29 Chipset This page details information of the chipset on AIMB 706 3 2 3 1 System Agent SA Configuration Figure 3 30 System Agent SA Conf...

Страница 62: ...4GB MMIO BIOS assignment Enable or Disable above 4GB MemoryMappedIO BIOS assignment IPU Device B0 D5 F0 Enable or Disable SA IPU device 3 2 3 2 Memory Configuration Figure 3 31 Memory Configuration M...

Страница 63: ...l Chapter 3 BIOS Operation 3 2 3 3 Graphics Configuration Figure 3 32 Graphics Configuration Primary Display Set Primary Display to Auto IGFX PEG PCI or SG Internal Graphics Set Internal Graphics to A...

Страница 64: ...Manual 54 3 2 3 4 PEG Port Configuration Figure 3 33 PEG Port Configuration Figure 3 34 PEG Port Feature Configuration Enable Root Port Enable or Disable the root port Max Link speed Configure PEG 0...

Страница 65: ...legacy network devices LAN2 Controller Enable or Disable LAN2 controller LAN2 Option ROM Enable or Disable LAN2 boot option for legacy network devices PCIE Wake Enable or Disable PCIE to wake the sys...

Страница 66: ...AIMB 706 User Manual 56 3 2 3 6 PCI Express Configuration Figure 3 36 PCI Express Configuration Figure 3 37 PCI Express Root Port PCI Express Root Port 5 Enable or Disable PCI Express Root Port...

Страница 67: ...troller SATA Mode Selection The SATA controller operates as AHCI mode SATA Controller Speed Indicates the maximum speed the SATA controller can support by selecting Default Gen1 Gen2 Gen3 Port 0 3 Ena...

Страница 68: ...AIMB 706 User Manual 58 3 2 3 8 USB Configuration Figure 3 39 USB Configuration XHCI Compliance Mode Option to Enable or Disable XHCI compliance mode Default is set to disable compliance mode...

Страница 69: ...ation RTC Memory Lock Enable will lock bytes 38h 3Fh in the lower upper 128 byte bank of RTC RAM BIOS Lock Enable or Disable the PCH BIOS Lock Enable feature Required to be enabled to ensure SMM prote...

Страница 70: ...Manual 60 3 2 3 10 HD Audio Configuration Figure 3 41 HD Audio Configuration HD Audio Control detection of the HD Audio device Disable HDA will be unconditionally disabled Enable HDA will be unconditi...

Страница 71: ...setup menu All Security Setup options such as password protection are described in this section To access the sub menu for the following items select the item and press Enter Note If only the User s...

Страница 72: ...r use the and keys to adjust the number of seconds to wait for setup activation key Bootup NumLock State Default state for the NumLock key during power on Quiet Boot Enable or Disable Quiet Boot optio...

Страница 73: ...ng Changes from the Exit menu and press Enter The follow ing message appears Save Configuration Changes and Exit Now Yes No 2 Select Yes or No Discard changes and exit Select this option to quit Setup...

Страница 74: ...AIMB 706 User Manual 64...

Страница 75: ...Chapter 4 4 Chipset Software Installation Utility...

Страница 76: ...perating system commands and the pertinent sections of your application softwares user manual before performing the installa tion 4 2 Introduction The Intel Chipset Software Installation CSI utility i...

Страница 77: ...Chapter 5 5 Integrated Graphic Device Setup...

Страница 78: ...lay options and 32 bit 3D graphics engine Dual independent display enhanced display modes for wide screen flat panels for extended twin and clone dual display mode and optimized 3D support delivers an...

Страница 79: ...Chapter 6 6 Intel ME...

Страница 80: ...be installed depend on the sys tem s specific hardware and firmware features The installer detects the system s capabilities and installs the relevant drivers and applications 6 2 Installation Enter t...

Страница 81: ...Chapter 7 7 LAN Configuration...

Страница 82: ...Wake on LAN WOL support PCIe x1 host interface 7 3 Installation The integrated Intel gigabit Ethernet controller supports all major network operating systems However the installation procedure varies...

Страница 83: ...Chapter 8 8 HD Audio...

Страница 84: ...n AIMB 706 is equipped with Realtek ALC892 Audio chip It provides Line out Microphone two ports for any related applications 8 2 Installation Enter the Advantech support website then search product AI...

Страница 85: ...Appendix A A Programming the Watchdog Timer...

Страница 86: ...roller NCT6776D It provides the following functions for user programming Can be enabled and disabled by user s program Timer can be set from 1 to 255 seconds minutes Generates an interrupt or resets s...

Страница 87: ...MB 706 User Manual Appendix A Programming the Watchdog Timer Unlock NCT6776D Select register of watchdog timer Enable the function of the watchdog timer Use the function of Lock NCT6776D the watchdog...

Страница 88: ...units for the timer Write 0 to bit 3 set seconds as counting unit default Write 1 to bit 3 set minutes as counting unit Write 1 to bit 4 Watchdog timer count mode is 1000 times faster If bit 3 is 0 th...

Страница 89: ...l 10 10 minutes Out dx al Dec dx lock NCT6776D Mov al 0aah Out dx al Enable watchdog timer and set 5 minutes as the timeout interval Mov dx 2eh unlock NCT6776D Mov al 87h Out dx al Out dx al Mov al 07...

Страница 90: ...ov dx 2eh unlock NCT6776D Mov al 87h Out dx al Out dx al Mov al 07h Select registers of watchdog timer Out dx al Inc dx Mov al 08h Out dx al Dec dx Enable the function of watchdog timer Mov al 30h Out...

Страница 91: ...al 30h Out dx al Inc dx Mov al 01h Out dx al Dec dx Enable watchdog timer to be strobed reset by keyboard Mov al 0f7h Out dx al Inc dx In al dx Or al 40h Out dx al Dec dx lock NCT6776D Mov al 0aah Ou...

Страница 92: ...al 82 Out dx al Inc dx In al dx Or al 01h Out dx al Dec dx Generate a time out signal Mov al 0f7h Out dx al Write 1 to bit 5 of F7 register Inc dx In al dx Or al 20h Out dx al Dec dx lock NCT6776D Mov...

Страница 93: ...Appendix B B I O Pin Assignments...

Страница 94: ...NEFEED 2 DATA0 15 ERROR FAULT 3 DATA1 16 INITIALIZE 4 DATA2 17 SELECT PRINTER SELECT IN 5 DATA3 18 GND 6 DATA4 19 GND 7 DATA5 20 GND 8 DATA6 21 GND 9 DATA7 22 GND 10 ACK 23 GND 11 BUSY 24 GND 12 PAPER...

Страница 95: ...4 GND 5 STDA_SSRX 6 STDA_SSRX 7 Shield GND_DRAIN 8 STDA_SSTX 9 STDA_SSTX Table B 4 USB 2 0 Port USB2C1 USB2A1 Pin Signal 1 5V 2 D 3 D 4 GND 1 Table B 5 USB 3 1 Header USB3H1 Pin Signal Pin Signal 1 5V...

Страница 96: ...ader USB2H1 Pin Signal Pin Signal 1 5V 2 5V 3 D 4 D 5 D 6 D 7 GND 8 GND 9 N A 10 N C 1 2 Table B 7 VGA Connector VGA1 Pin Signal Pin Signal 1 RED 9 KEY PWR 2 GREEN 10 GND 3 BLUE 11 ID0 RES 4 ID2 RES 1...

Страница 97: ...ND 2 TMDS Data 2 14 5V 3 TMDS Data 2 4 shield 15 GND 4 GND 16 Hot plug detect 5 GND 17 TMDS data 0 6 DDC clock 18 TMDS data 0 7 DDC data 19 TMDS data 0 5 shield 8 NC 20 GND 9 TMDS Data 1 21 GND 10 TMD...

Страница 98: ...6 Pin Signal 1 DCD 2 DSR 3 RXD 4 RTS 5 TXD 6 CTS 7 DTR 8 RI 9 GND Table B 11 RS 232 422 485 Header COM3 Pin Signal 1 422 485 TX 2 DSR 3 422 485 TX 4 RTS 5 RX 6 CTS 7 RX 8 RI 9 GND Table B 12 External...

Страница 99: ...al Speaker Connector JFP2 Table B 13 CPU and System Fan Power Connector CPUFAN1 SYSFAN1 SYSFAN3 Pin Signal 1 GND 2 12 V 3 SENSE 4 PWM 1 Table B 14 Power LED and Keyboard Lock JFP3 Pin Function 1 POWER...

Страница 100: ...16 Reset Connector JFP1 Table B 16 HDD LED Connector JFP2 Pin Signal 2 HDD_LED 5 HDD_LED 2 5 Table B 17 SMBus Connector JFP2 Pin Signal 8 SMB_SNMP_SDAT 11 SMB_SNMP_SCLK 8 11 Table B 18 ATX Soft Power...

Страница 101: ...B 20 8 pin Alarm Board Connector VOLT1 Pin Signal Pin Signal 1 5V_STBY 5 5 V 2 GND 6 3 3 V 3 GND 7 12 V 4 5 V 8 12 V 1 Table B 21 Case Open Connector JCASE1 Pin Signal 1 CASEOP 2 GND 1 Table B 22 Fro...

Страница 102: ...V3 3V 2 GND 3 CS 4 CLK 5 MISO 6 MOSI 7 N A 8 N C Table B 24 Low Pin Count Connector LPC1 Pin Signal Pin Signal 1 CLK 24MHz 2 AD1 3 RESET 4 AD0 5 FRAME 6 3 3V 7 AD3 8 GND 9 AD2 10 SMB CLK 11 SERIRQ 12...

Страница 103: ...SMBUS1 B 24 Front Panel Audio Connector FPAUD1 Table B 26 SMBus Connector SMBUS1 Pin Signal 1 V5 2 SMB CLK 3 SMB DAT 4 GND 1 Table B 27 Front Panel Audio Connector FPAUD1 Pin Signal 1 MIC L 2 GND 3 M...

Страница 104: ...chdog Timer Output and HW Monitor Alarm JWDT1 JOBS1 Table B 28 Watchdog Timer Output and HW Monitor Alarm JWDT1 JOBS1 Pin Signal Pin Signal 1 5V 6 SYSTEM RESET 2 N C 7 GND 3 N C 8 ERROR_BEEP 4 WG 9 IR...

Страница 105: ...95 AIMB 706 User Manual Appendix B I O Pin Assignments...

Страница 106: ...ions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion fro...

Отзывы: