AGS-910 User Manual
iv
Safety Information
Retain and follow all product safety and operating instructions provided with your
equipment. In the event of a conflict between the instructions in this guide and the
instructions in equipment documentation, follow the guidelines in the equipment doc-
umentation.
Observe all warnings on the product and in the operating instructions. To reduce the
risk of bodily injury, electric shock, fire and damage to the equipment, observe all pre-
cautions included in this guide.
You must become familiar with the safety information in this guide before you install,
operate, or service Advantech products.
Machine Room Environment
Make sure that the area in which you install the system is properly ventilated
and climate-controlled.
Ensure that the voltage and frequency of your power source match the voltage
and frequency inscribed on the electrical rating label of the equipment.
Do not install the system in or near a plenum, air duct, radiator, or heat register.
Never use the product in a wet location.
Equipment Chassis
Do not block or cover the openings to the system.
Never push objects of any kind through openings in the equipment.
Dangerous voltages might be present.
Conductive foreign objects can produce a short circuit and cause fire, electric
shock, or damage to your equipment.
Lift equipment using both hands and with your knees bent.
Rack Mount Instructions
The following or similar rack-mount instructions are included with the installation
instructions:
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than
room ambient. Therefore, consideration should be given to installing the equip-
ment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that
the amount of air flow required for safe operation of the equipment is not com-
promised.
Mechanical Loading - Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable Earthing - Reliable earthing of rackmounted equipment should be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g. use of power strips)."
Содержание AGS-910
Страница 11: ...Chapter 1 1 Overview...
Страница 21: ...Chapter 2 2 Setting up...
Страница 32: ...AGS 910 User Manual 22 3 Release the expansion card holder 4 Unscrew the IO bracket from the card cage...
Страница 43: ...Chapter 3 3 AMI BIOS...
Страница 50: ...AGS 910 User Manual 40 3 2 2 4 WHEA Support WHEA Support Enable or disable Windows Hardware Error Architecture...
Страница 51: ...41 AGS 910 User Manual Chapter 3 AMI BIOS 3 2 2 5 CPU Configuration Socket 0 Socket 1 CPU Information...
Страница 60: ...AGS 910 User Manual 50 3 2 2 10 Super I O Configuration Serial Port 0 Configuration...
Страница 64: ...AGS 910 User Manual 54 3 2 3 Chipset 3 2 3 1 North Bridge...
Страница 73: ...63 AGS 910 User Manual Chapter 3 AMI BIOS 3 2 3 3 ME Subsystem 3 2 4 Server Management...
Страница 78: ...AGS 910 User Manual 68 3 2 6 Security...
Страница 80: ...AGS 910 User Manual 70...
Страница 81: ...Chapter 4 4 Chipset Software Installation Utility...
Страница 84: ...AGS 910 User Manual 74 2 Click setup to execute program...
Страница 85: ...Chapter 5 5 VGA Setup...
Страница 87: ...Chapter 6 6 LAN Configuration SATA RAID AHCI Setup...
Страница 91: ...Appendix A A Programming the Watchdog Timer...
Страница 93: ...83 AGS 910 User Manual Appendix A Programming the Watchdog Timer...