background image

ADAM-6521 Series User Manual

iv

CE

This product has passed the CE test for environmental specifications 
when shielded cables are used for external wiring. We recommend the 
use of shielded cables. This kind of cable is available from Advantech. 
Please contact your local supplier for ordering information.

FCC Class A

Note: This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Opera-
tion of this equipment in a residential area is likely to cause harmful inter-
ference in which case the user will be required to correct the interference 
at his own expense. 

Technical Support and Assistance

Step 1.  Visit the Advantech web site at 

www.advantech.com/support

 

where you can find the latest information about the product.

Step 2.  Contact your distributor, sales representative, or Advantech's 

customer service center for technical support if you need addi-
tional assistance. Please have the following information ready 
before you call:
- Product name and serial number
- Description of your peripheral attachments
- Description of your software (operating system, version, appli-
cation software, etc.)
- A complete description of the problem
- The exact wording of any error messages

Document Feedback

To assist us in making improvements to this manual, we would welcome 
comments and constructive criticism. Please send all such - in writing to: 
[email protected]

Содержание ADAM-6521 Series

Страница 1: ...ADAM 6521 Series Industrial Switches with 4 10 100 Mbps Ethernet Ports and 1 Fiber Port User Manual...

Страница 2: ...ten permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reli able However Advantech Co Ltd assumes no responsibility for its use nor for any infringements...

Страница 3: ...lacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enc...

Страница 4: ...dio communications Opera tion of this equipment in a residential area is likely to cause harmful inter ference in which case the user will be required to correct the interference at his own expense Te...

Страница 5: ...9 Figure 2 1 Bottom 9 Figure 2 2 Top 9 Figure 2 3 Front 9 2 3 Mounting the Module 10 2 3 1 Choosing a Mounting Method 10 Figure 2 4 Wall Mounting 10 Figure 2 5 Attaching DIN Rail Bracket 11 Figure 2...

Страница 6: ...ADAM 6521 Series User Manual vi...

Страница 7: ...2 CHAPTER 1 Overview This chapter gives an overview of ADAM 6521 modules Sections include Introduction Features Specifications Ordering Information...

Страница 8: ...5 C The above functions make the ADAM 6521 modules more stable and reliable so they are especially suitable for industrial environ ments that require Ethernet networking such as semiconductor factorie...

Страница 9: ...ber port with SC ST connector Supports full half duplex flow control Supports MDI MDI X auto crossover Provides broadcast storm protection Embedded with a switch controller supports auto negotiation E...

Страница 10: ...SC type fiber connector ADAM 6521 ADAM 6521S or 1 x ST type fiber connector ADAM 6521 ST LED Indicators Power Link 100Base FX 100 10M Ethernet Power Power Connectors 2 pin removable screw terminal Po...

Страница 11: ...strial Switch with 4 10 100 Mbps Ethernet Ports 1 Single mode SC Type Fiber Optic Port Environment Operating Temperature 10 65 C 14 149 F Stack 10 60 C 14 140 F Storage Temperature 20 80 C 4 176 F Ope...

Страница 12: ...ADAM 6521 Series User Manual 6...

Страница 13: ...CHAPTER 2 Installation In this chapter you will be given an overview of the ADAM 6521 series hardware installation procedure Sections include LED Indicators Dimensions Mounting the Module Connections...

Страница 14: ...dicator Color Status Description Power Green On Power is on Green Off Power is off Link 100BASE FX Green Orange On Connected to network Green Orange Flashing Networking is active Green Orange Off Not...

Страница 15: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Bottom Figure 2 2 Top Figure 2 3 Front...

Страница 16: ...the ADAM 6521 modules can be Fixed to a wall Fixed to a DIN Rail Piggyback Stacked Panel Mounting ADAM 6521 modules can be attached to a wall using the included brack ets Each bracket comes with four...

Страница 17: ...to the ADAM mod ule Because ADAM 6521 modules use special hex head slotted shoulder screws the tops of the screws will be even with the front of the module Snap the module onto the DIN rail Figure 2...

Страница 18: ...s via a two pair straight through cable or crossover cable The connection can be made from any port on ADAM 6521 modules MDI X to other hubs or switches either by either an MDI X port or uplink MDI po...

Страница 19: ...Power Connection You should take the following steps to connect ADAM 6521 modules to a power supply 1 Connect the power cable to a 2 pin connector 2 Connect the power cable to a power adapter Figure...

Страница 20: ...ADAM 6521 Series User Manual 14...

Отзывы: