2-4 ADAM 4100 Series User’s Manual
Installation Guideline
ADAM Utility Software
A menu-driven utility program is provided for ADAM module
configuration, monitoring and, calibration. It also includes a terminal
emulation program that lets you communicate through the ADAM
command set. (See Appendix A, Utility Software)
ADAM Communication Speed
In ADAM series, the baud rate can be configured from 1200 bps to
115.2 Kbps. However, the baud rate of all modules in an RS-485
network must be the same.
ADAM Isolated RS-232/RS485 Converter (optional)
When the host computer or terminal only has a RS-232 port, an ADAM
Isolated RS-232/RS-485 Converter is required. Since this module is not
addressable by the host, the baud rate must be reset using a switch
inside the module. The factory default setting is 9600 baud.
ADAM Repeater (optional)
When communication lines exceed 4000 ft (1200 meter) or more than
32 ADAM modules are connected, a repeater should be implemented.
In a network, up to eight Repeater modules can be connected allowing
connection up to 255 ADAM modules. As with the Converter module,
the Repeater module is not addressable by the host and the baud rate
must be reset by changing the switch inside the module. The factory
default setting is 9600 baud.
Содержание ADAM 4100
Страница 1: ...ADAM 4100 Industrial Grade Data Acquisition Modules User s Manual ...
Страница 5: ...Introduction 1 ...
Страница 9: ...Installation Guideline 2 ...
Страница 24: ...I O Modules 3 ...
Страница 25: ......
Страница 37: ...Chapter 3 I O Modules 3 13 I O Modules Figure 3 10 Digital Output used with SSR ADAM 4150 ...
Страница 40: ...Command Set 4 ...
Страница 41: ......
Страница 51: ......
Страница 105: ...Calibration 5 ...
Страница 109: ...5 4 ADAM 4100 Series User s Manual ...
Страница 110: ...Utility Software A ...
Страница 111: ......
Страница 121: ...ADAM 4100 I O Modbus Mapping Table B ...
Страница 131: ...Technical Diagrams C ...
Страница 132: ...C 2 ADAM 4100 Series User s Manual Appendix C C 1 ADAM Dimensions Figure C 1 ADAM Modules Dimensions ...
Страница 134: ...C 4 ADAM 4100 Series User s Manual Appendix C Figure C 3 DIN Rail Mounting ...
Страница 135: ...Appendix C Technical Diagrams C 5 Technical Diagrams C 2 2 Panel Mounting Figure C 4 Panel Mounting Bracket Dimensions ...
Страница 136: ...C 6 ADAM 4100 Series User s Manual Appendix C Figure C 5 Panel Mounting ...
Страница 137: ...Appendix C Technical Diagrams C 7 Technical Diagrams C 2 3 Piggyback Stack Figure C 6 Piggyback Stack ...
Страница 138: ...Data Formats and I O Ranges D ...
Страница 142: ...RS 485 Network E ...
Страница 143: ......
Страница 150: ...How to use the Checksum feature F ...
Страница 154: ...Changing Configuration to Modbus Protocol G ...