ADAM-4000 Series User Manual
10
The following items are required to configure a module: an ADAM converter module,
a personal computer with RS-232 port (baud rate set to 9600) and the ADAM utility
software.
Configuration with the ADAM Utility Software
The easiest way to configure the ADAM module is by using the ADAM utility soft
-
ware. It is a user friendly structured menu program that will guide you through every
step of the configuration. (See Appendix D, Utility Software)
Changing the protocol from ADAM ASCII to Modbus
Some ADAM-4000 modules support both ADAM ASCII and Modbus protocols, and
the factory default setting of these modules is ADAM ASCII protocol. If you would like
to configure the modules to Modbus protocol, please refer to Appendix H which
describes how to change the protocol in ADAM utility.
Configuration with the ADAM command set
ADAM modules can also be configured by issuing direct commands through a termi
-
nal emulation program that is part of the ADAM utility software. The following exam
-
ple will guide you through the setup of an analog input module. Assume an ADAM-
4011 Analog Input module still has its default settings (baud rate 9600 and address
01h), and you are being requested to send its default settings before any reconfigura
-
tion is made.
Example:
Make sure that the module is properly connected and turn on all the connected
devices. Then, start the terminal emulation program, and type in the following com
-
mand:
$012(cr)
The command above requests the module with address 01 to send its configuration
status
!01050600
Module at address 01 responds that it is configured for an input range of +/-2.5 V,
baud rate of 9600, integration time of 50 ms (60 Hz).
The code also shows engineering units and no checksum checking or generation.
To change the configuration setting of the analog input module, the following com
-
mand is issued:
%01070F0600(cr)
% = change configuration
01 = target module at address 00 to:
07 = change address to 07 hexadecimal
0F = set input range to Type K thermocouple
06 = set baud rate to 9600
00 = set integration time to 50 ms (60 Hz)
disable checksum
Note!
An analog input module requires a maximum of 7 seconds to perform
auto calibration and ranging after reboot or start up.
During this time span, the module can not be addressed to perform any
other actions.
Содержание Adam - 4021
Страница 1: ...User Manual ADAM 4000 Series Data Acquisition Modules...
Страница 4: ...ADAM 4000 Series User Manual iv...
Страница 12: ...ADAM 4000 Series User Manual xii...
Страница 13: ...Chapter 1 1 Introduction...
Страница 16: ...ADAM 4000 Series User Manual 4...
Страница 17: ...Chapter 2 2 Installation Guideline...
Страница 33: ...Chapter 3 3 I O Modules...
Страница 36: ...ADAM 4000 Series User Manual 24 3 2 1 Application Wiring Figure 3 2 ADAM 4015 RTD Input Module Wiring Diagram...
Страница 78: ...ADAM 4000 Series User Manual 66...
Страница 79: ...Chapter 4 4 Command Set...
Страница 99: ...87 ADAM 4000 Series User Manual Chapter 4 Command Set...
Страница 100: ...ADAM 4000 Series User Manual 88...
Страница 101: ...Chapter 5 5 Analog Input Module Commands...
Страница 127: ...Chapter 6 6 Analog Output Module Commands...
Страница 144: ...ADAM 4000 Series User Manual 132...
Страница 145: ...Chapter 7 7 I O Relay Counter Frequency...
Страница 201: ...Chapter 8 8 Calibration...
Страница 206: ...ADAM 4000 Series User Manual 194...
Страница 207: ...Appendix A A Technical Specifications...
Страница 211: ...199 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 2 ADAM 4018 Function Diagram...
Страница 213: ...201 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 3 ADAM 4019 Function Diagram...
Страница 215: ...203 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 4 ADAM 4021 Function Diagram...
Страница 216: ...ADAM 4000 Series User Manual 204 Figure A 5 ADAM 4024 Function Diagram...
Страница 219: ...207 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 7 ADAM 4051 4052 Function Diagram...
Страница 221: ...209 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 8 ADAM 4053 Function Diagram...
Страница 223: ...211 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 9 ADAM 4055 Function Diagram...
Страница 225: ...213 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 10 ADAM 4056S Function Diagram...
Страница 227: ...215 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 11 ADAM 4056SO Function Diagram...
Страница 229: ...217 ADAM 4000 Series User Manual Appendix A Technical Specifications Figure A 12 ADAM 4060 Function Diagram...
Страница 232: ...ADAM 4000 Series User Manual 220 Figure A 14 ADAM 4080 Function Diagram...
Страница 233: ...Appendix B B Data Formats and I O Ranges...
Страница 244: ...ADAM 4000 Series User Manual 232...
Страница 245: ...Appendix C C Technical Diagrams...
Страница 246: ...ADAM 4000 Series User Manual 234 C 1 ADAM Dimensions Figure C 1 ADAM Modules Dimensions...
Страница 248: ...ADAM 4000 Series User Manual 236 Figure C 3 DIN Rail Mounting...
Страница 250: ...ADAM 4000 Series User Manual 238 C 2 3 Piggyback Stack Figure C 6 Piggyback Stack...
Страница 251: ...Appendix D D Utility Software...
Страница 258: ...ADAM 4000 Series User Manual 246...
Страница 259: ...Appendix E E RS 485 Network...
Страница 264: ...ADAM 4000 Series User Manual 252...
Страница 265: ...Appendix F F Using the Checksum Feature...
Страница 268: ...ADAM 4000 Series User Manual 256...
Страница 269: ...Appendix G G I O Modbus Mapping Table...
Страница 283: ...Appendix H H Changing to Modbus Protocol...
Страница 285: ...273 ADAM 4000 Series User Manual Appendix H Changing to Modbus Protocol...