SSPBMg-C400-BRE
11.3 COMMANDS
These commands go only from master-slave direction.
TABLE 10:
COMMANDS
No
Description
2nd byte
3, 4, 5 &6 bytes
Respond. 2,3,4,5,6
bytes.
1
Request condition
status
0x01 or 0x2A 0xAA AA AA AA
See
TABLE 11
2
command
2
0x5A AA AA AA To mute
0xA5 AA AA AA To unmute
See
TABLE 11
Mute/Unmute
0x0
3
0x03
Valid address = 0x01 to 0x0F
Byte 4,5,6 : 0xA5
See
TABLE 11
Change Unit
Byte 3 = Unit Address
Address
4
gain/attenuation.
Byte 3=0x5A To set Gain
Byte 4,5: Gain/Attenuation
See
TABLE 11
Set
0x05
Byte 3=0x55 To set Attenuation
value to set
Byte 6: 0xAA
5
0x07
0xAA AA AA AA
See
TABLE 12
Read Identification
6
Read serial
I characters
number
0x08
0xAA AA AA AA
5 ASCI
7
0x0A
0x5A AA AA AA To read gain
0x55 AA AA AA To read
attenuation
Byte 2, 3: Gain
value
Read
gain/attenuation
8
Byte 2, 3: days Byte
te 5,6:
0xAA
Read elapse time
0x0C
0xAA AA AA AA
4: hours. By
(future cmd)
9
tion
0x0D
0x5A AA AA AA To read gain
range
0x55 AA AA AA To read
ge
See
TABLE 13
Read
gain/attenua
range
attenuation ran
1
0xAA AA AA AA
Byte 2, 3:
Temperature
Byte 4,5,6: 0xAA
0
Read Hot Spot
temperature
0x12
1
wer level
0xAA AA AA AA
d
power
Byte 4,5,6: 0xAA
1
po
Read forward
0x25
Byte 2,3: Forwar
Page
39
Содержание SSPBMg-C400-BRE
Страница 12: ...SSPBMg C400 BRE Figure 1 Product Outline Page 11 ...
Страница 13: ...SSPBMg C400 BRE Figure 2 Product Outline fans side view Page 12 ...
Страница 17: ...SSPBMg C400 BRE Figure 4 Connectors Page 16 ...
Страница 29: ...SSPBMg C400 BRE Figure 7 HyperTerminal RS 232 Communication help command and response Page 28 ...
Страница 30: ...SSPBMg C400 BRE Figure 8 HyperTerminal RS 232 Communication status command and response Page 29 ...