PROPER CARE AND CLEANING
WARNING:
Always remove the plug from the electric socket before performing any
maintenance or cleaning.
General
1. For best results, it is recommended to change the filters every 3000 litres or 12 months,
whichever comes first.
2. It is also recommended to drain off the water within the dispenser every month by releasing
water through the Water Drainage Outlet
R
.
Beware:
Water flowing out can be very hot.
3. The spilled water in the Drip Tray
H
must be removed and cleaned regularly.
Cleaning HOT and COLD Water Tank
1. Turn off power supply and remove plug from socket.
2. Close water supply and turn off HOT Water Heater Switch
L
.
3. Drain all the water in the COLD Water Tank through the
COLD Water Tap
G
.
4. Remove the cap of the Water Drainage Outlet
R
.
(BE CAREFUL not to get burned by the hot
water when opening the cap.)
5. Remove the 2 screws
W
on the rear side on the
Top Cover
J
with a Phillips Screwdriver.
6. Lift up the Top Cover
J
from the rear and
detach from the dispenser. Then separate the COLD Water
Tank Cover in the unit. (When separating the tank cover,
be careful not to damage the rubber seal. The cold water
tank is made of stainless steel be careful not to hurt your
hands)
7. Remove the Separating Disc by pulling up vertically.
8. Clean the inside of the COLD Water Tank by
pouring water into it. After water drains out,
close the Water Drainage Outlet
R
.
9. Clean and dry the Stainless Steel COLD Water
Tank with a clean cloth or kitchen towel.
DO NOT
USE any chemical or detergent.
10. Reposition the Separating Disc, COLD Water Tank
Cover and Top Cover
J
in order.
11. Secure Top Cover Assembly with the screws
W
at
the rear side of the dispenser.
12. Turn on the water supply valve and look out for
leakage when the HOT and COLD Water Tanks are being
filled.
13. Make sure water can be dispensed from the HOT
F
and
COLD
G
water tap before proceeding to the next step.
14. Insert plug into a 13Amp socket, turn switch ON. The
compressor will start working to chill the COLD Water
Tank.
15. Turn on HOT Water Heater Switch
L
to have hot water
supply.
(If you notice something unusual, contact Service Centre for
assistance.)
COLD Water
Tank Cover
Stainless
Steel
COLD
Water
Tank
Separating
Disc
Separating
Disc
Support
(
DO NOT REMOVE
)
Содержание Alkaline Plus H2O AP-S
Страница 1: ......