IX.  Manufacturer’s Product Warranty

 

 

Advantage Controls warrants units of its manufacture to be free of defects in material or 

workmanship.  Liability under this policy extends for 24 months from date of installation.  Liability is limited 

to repair or replacement of any failed equipment or part proven defective in material or workmanship upon 

manufacturer’s examination.  Removal and installation costs are not included under this warranty.  

Manufacturer’s liability shall never exceed the selling price of equipment or part in question.

 

Advantage disclaims all liability for damage caused by its products by improper  installation, 

maintenance, use or attempts to operate products beyond their intended  functionality, intentionally or 

otherwise, or any unauthorized repair.   Advantage is not  responsible for damages, injuries or expense 

incurred through the use of its products.

 

The above warranty is in lieu of other warranties, either expressed or implied.  No agent of ours is 

authorized to provide any warranty other than the above.

30 Day Billing Memo Policy 

 

 

Advantage Controls maintains a unique factory exchange program to ensure uninterrupted service 

with minimum downtime.  If your unit malfunctions, call 1-800-743-7431, and provide our technician with 

Model and Serial Number information.  If we are  unable to diagnose and solve your problem over the phone, 

a fully warranted replacement unit will be shipped, usually within 48 hours, on a 30 Day Billing Memo.

 

This service requires a purchase order and the replacement unit is billed to your regular account for 

payment.

 

The replacement unit will be billed at current list price for that model less any applicable resale 

discount.  Upon return of your old unit, credit will be issued to your account if the unit is in warranty.  If the unit 

is out of warranty or the damage not covered, a partial credit will be applied based upon a prorated 

replacement price schedule dependent on the age of the unit.  Any exchange covers only the controller 

or pump.  Electrodes, liquid end components and other external accessories are not included.

FCC Warning

This equipment generates and uses radio frequency energy and if not installed and used properly, 

that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio 

communications.  It has been type tested and found to comply with the limits for a class A computing 

device pursuant to subpart J of part 15 of FCC Rules, which are designed to provide reasonable 

protection against such interference when operated in a commercial or industrial environment. 

Operation of this equipment in a residential area is likely to cause interference in which case the user, 

at his own expense, will be required to take whatever measures necessary to correct the interference.

Содержание NanoTron Nano-P

Страница 1: ...R P pH R ORP Installation Maintenance Repair Manual Advantage Controls 4700 Harold Abitz Dr Muskogee OK 74402 Phone 918 686 6211 Fax 888 686 6212 www advantagecontrols com email support advantagecontrols com 04 2019 ENTER ...

Страница 2: ...stallation Electrical Wiring 4 Mounting Instructions 4 Logic and Relay Cards 5 Electrode Installation 6 IV Front Panel Description 7 V NanoTron P R Menu Map 8 VI System Operation Overview 10 Description of Menus 10 VII Maintenance 10 VIII Troubleshooting 11 IX Warranty 30 Day Billing Memo Policy 12 ...

Страница 3: ... or ORP and Relay 2 is labeled Relay 2 if pigtails are provided A force on timer that allows for manual activation of the relays for a user defined amount of time pH Control P The pH function monitors and controls pH on a scale of 0 14 pH units The unit can be configured for single or dual set point control Relay 1 is controlled be the single pH set point with the following settings Set Point risi...

Страница 4: ...ont panel is in the OFF position Never open the front panel without first disconnecting power from the outlet Prewired controllers are supplied with an 8 foot 18 AWG power cord with USA style plug A 1 Phillips driver is required to open the front panel 2 Low voltage signal wires probes flow switch water meter etc should never be run in conduit with high voltage like 115VAC wires 3 Never attempt to...

Страница 5: ...ast Adjust Note Use GND and N O for N O dry contact relay or use GND and N C for N C dry contact relay 1 2 3 4 5 ON OFF Reset Battery FUSE Relay 1 Ribbon Cable Relay 2 Power In H N G FUSE POWER SUPPLY RELAY 1 RELAY 2 Dry GND GND Hot Dry Hot N e u t r a l G r o u n d N O N C N e u t r a l G r o u n d N O N C GND Dry Hot Relays can be a dry contact by changing the jumpers and connecting to Ground an...

Страница 6: ...sure in order for water to flow past the electrode s to achieve the required rate NOTES 1 Install an isolation valve on either side of the flow assembly so electrode can be easily isolated for removal and cleaning 2 A line strainer is recommended upstream from the probes to protect against fouling and damage 3 Mount pH or ORP electrodes vertically 4 Green solution reference wire must be connected ...

Страница 7: ...ress MENU to access menus or go back one layer in menu structure Press FORCE to activate relays manually again for Off and a third time back to auto Press ENTER to go a layer deeper in menu to initiate a setting change and to set change Use up or down arrows to navigate through menu selections or setting options Use left or right arrows to move cursor while making a numerical value change ENTER Re...

Страница 8: ...XXXX Setpoint 0300 Diff 010 Direction Rise High Alarm 0400 Low Alarm 0100 Limit hh mm ORP Set Alarms Relay 2 Set Pulse Run After 0010 Run Time mm ss Timer Off 28 Day Bio A All Days A All Weeks A Start 12 00a A Run Time hh mm B All Days B All Weeks B Start 12 00a B Run Time hh mm Recycle Off Time hh mm Run Time mm ss Utility Only shows in timer mode Mode Timer Alarm Sim 4mA XXXX Sim 20mA XXXX ORP p...

Страница 9: ...m Relay 1 Factory Feed OK NoFlow No Feed No Flow Only applies to active timers Configure Lo Rate XXXX Hi Rate XXXX Hi minute XXX Pulse Output Should not exceed max pulse rate of pump Alarm Only Relay 1 Relay 2 Relay 1 or 2 V NanoTron P R Menu Map NanoTron pH ORP units have a main menu circle that includes Calibration Calibrating the conductivity reading Alarm List Shows active alarms pH ORP Set Se...

Страница 10: ...ime to force them off for the same amount of time Press a third time to go back to automatic Run mode Unit returns to the Run mode automatically when the force time has elapsed VII Maintenance The only required maintenance for normal uninterrupted operation of your Nano P R controller is cleaning of the electrode ORP and pH sensors have a 6 18 month life depending on installation and will need to ...

Страница 11: ...rode Clean as needed Out of calibration Calibrate unit Will not calibrate Dirty electrode Clean electrode Faulty electrode Replace electrode if needed Faulty wiring to electrode Replace wiring if needed No system power Check power source Plug into different receptacle Check fuse Replace as needed Check connections Make sure ribbon cables are secure Pulse timer not activating Check wiring Repair as...

Страница 12: ...n If we are unable to diagnose and solve your problem over the phone a fully warranted replacement unit will be shipped usually within 48 hours on a 30 Day Billing Memo This service requires a purchase order and the replacement unit is billed to your regular account for payment The replacement unit will be billed at current list price for that model less any applicable resale discount Upon return ...

Отзывы: