background image

MyDict - MyAir3 as Master with Panasonic A/C 

 

2

 

2013 

 

Panasonic Unit 
 

1.

 

Install the Panasonic indoor and outdoor unit according to Panasonic’s instructions.  Do not 
connect any MyAir  electronics.  

2.

 

Connect up the Panasonic  wall controller in the roof space, there is no need to run the 
controller down the wall as it will be only be used to configure the system initially then it will be 
disconnected & removed later. 

3.

 

Test the Panasonic system completely using this Panasonic wall controller.  

4.

 

Once testing is complete proceed to next step (Field Settings). 

Panasonic Field Settings  

Setup the Panasonic wall controller as follows for the CZ-
RTC2 Panasonic remote controller. 

NOTE:

 There are two separate field settings menus that you 

need to access and change. 

1.

 

Menu  1 

a.

 

Press and hold the MODE (Top Right) & TIMER 
SET buttons together on the remote controller 
for more than 4 seconds. 

b.

 

Select the code you would like to change with 
the UP & DOWN 

TEMPERATURE

 buttons 

c.

 

Change the codes value with UP & DOWN 

TIMER

 

buttons 

d.

 

Set the following 

i.

 

01 = 0001

 

ii.

 

OA = 0001 (

Essential for MyZone

TM

 feature when using MyAir temperature 

sensors

).

 

e.

 

When  you are done press the SET button 

f.

 

Then press the SPANNER button 

g.

 

Remote returns to main screen 