Advanced Technology Video QuadraSplit 421SS Скачать руководство пользователя страница 6

 

QSP-421SS: Instructions for basic operation and installation

         Page

6

I

NPUT 

T

ERMINATION

The “C” jumpers affect the camera input termination resistor. When
the jumper is installed a 75 Ohm termination is connected to the
respective cameras. Additionally the “V” jumper serves the same
purpose on the VCR input. For proper operation a termination resistor
of 75 ohms should be on the last piece of video equipment which is
connected to a given camera. For a simple system where cameras
are brought directly into the QSP-421SS, the termination resistors are
always enabled (factory default). When connecting a camera to more
than one piece of equipment, or if “loop through” is used, individual
terminating resistor jumpers should be removed and the termination
should be made at the monitor(s).

A

LARM 

C

ONTACTS

The “A” jumper affects whether the alarm inputs are active when the
contacts are closed (jumper installed - factory default) or open (jumper not installed). In either case the
assumption is that the alarm contacts connect together the ground pin and the alarm input pin associated
with a particular camera. For “normally open” type contacts, the “A” jumper should be installed.  For
“normally closed” type contacts, the “A” jumper should not be installed. The QSP-421SS assumes that all
the alarm inputs are of the same type. Selecting an incompatible combination of contact type and option
setting will result in the QSP-421SS being in a continuous “alarm” condition which is indicated by the unit
to seemingly be stuck in full frame sequencing mode, and generating a continuous alarm output state.
Please note that if less than four alarm inputs are used and “A” jumper is not installed, the remaining
alarm inputs must be grounded (Tied to pin 10).

D

WELL 

O

PTIONS

The QSP-421SS dwell time is set by SW9 and affects the
amount of time between camera changes. The dwell
setting is set to a factory default of 4 seconds but is
adjustable in 4 sec steps from 4 to 16 seconds.

The dwell time affects:

1.  Full frame sequencing dwell time.

2.  PIP background sequencing dwell time.

3.  PIP insert sequencing dwell time.

4.  Alarm full frame sequencing dwell time

(when more than one simultaneous alarm input).

F

IELD

/F

RAME

 M

ODE

 S

ELECTION

Switch positions #1 and #2 on SW9 control how video field information is handled.  We have preset them to
defaults that should work with most systems, but there is a very large variation in the behavior of VCRs and you
may have to experiment with the settings that work best for your installation.

Camera

Camera

Camera

Camera

75ohm

75ohm

75ohm

75ohm

Other Video

Equipment

Without 75ohm

QSP421SS

Tee

Tee

Loop

Through

Other

Equipment

1

2

3

4

SW9:  Dwell Time Setting

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

Seconds

8

12

16

4

Field/Frame 

Field/Frame Mode Selection

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

(Factory Default Shown)

Dwell Time 

Seconds

Seconds

Seconds

Field Mode Toggle

Field Mode Single

Frame Mode Force Odd

Frame Mode Force Even

Содержание QuadraSplit 421SS

Страница 1: ...r s Manual and Operating Instructions Instructions for basic operation and installation Printing Revision 2 10 22 97 For Serial numbers 2300500 and greater for EIA For Serial numbers 2400500 and greater for CCIR 000 ...

Страница 2: ...A CCIR versions EQUIPMENT INTERCONNECTION EQUIPMENT REQUIREMENTS The QSP 421SS is designed to be compatible with all EIA and CCIR compatible equipment Two versions of the product are available to make best use of these two standards The EIA version indicated by serial numbers 23 will only be compatible with EIA installations The CCIR version indicated by serial numbers 24 will be compatible with b...

Страница 3: ...LIT TM 421SS VCR QUAD CAMERA ZOOM MODE FRONT PANEL OPERATION Using the figure above as your guide you can select different display modes by pressing one or more of the following four buttons QUAD Returns the unit to QUAD MODE directly from any other mode MODE Switches from QUAD MODE and with each press cycles through FULL SCREEN MANUAL PICTURE IN PICTURE FULL SCREEN SEQUENCING PIP BACKGROUND SEQUE...

Страница 4: ...nputs and corresponding looping outputs 8 total One BNC connector is provided for a VCR input another for an output to the VCR and another for the output to a monitor Cameras 1 through 4 connectors are labeled with their display position in the quad mode display Each camera input of the QSP 421SS supports loop though with a second BNC connector The loop through 75 ohm termination resistor within t...

Страница 5: ...olt pin or some other higher voltage not to exceed 25 Volts sometimes used in 12 Volt systems The off or open circuit voltage on the alarm output should not exceed 25 Volts to avoid damaging the alarm output 1 2 3 4 VCR Audible Alarm Relay Alarm Inputs 8 5 10 5 8 5 30 mA Max Alarm Outputs OR OR 8 10K Optional High Voltage Current The 5 Volt and ground pins are connected through an internal 100 ohm...

Страница 6: ...ype and option setting will result in the QSP 421SS being in a continuous alarm condition which is indicated by the unit to seemingly be stuck in full frame sequencing mode and generating a continuous alarm output state Please note that if less than four alarm inputs are used and A jumper is not installed the remaining alarm inputs must be grounded Tied to pin 10 DWELL OPTIONS The QSP 421SS dwell ...

Страница 7: ...es when the VCR is in playback but paused the picture will jump vibrate by one line Setting SW9 Position 1 to ON usually compensates for this For most other cases SW9 Position 1 should be OFF FRAME MODE SW9 POSITION 2 ON In frame mode each independent field which makes up a frame will get displayed for monitoring or recording In a system without a VCR frame is the recommended mode of operation sin...

Страница 8: ... misuse neglect faulty installation or adjustment of controls or improper maintenance Except as herein expressly set forth Advanced Technology Video Inc shall not under any circumstances be responsible for any direct indirect incidental or consequential damages including but not limited to damage to the equipment For warranty service you must obtain a return authorization number by calling 425 885...

Отзывы: