Z-Wave ZRW 113 Instructions, Series 200, Release 2.2

P/D 011008

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0766-01

3

Association

The ZRW113 supports the Association command.

The ZRW113 can be set to control other Z-Wave devices.  You can turn on and off, and even dim other Z-Wave devices
once they are “

associated

” into either of 2 groups of the ZRW113.

Each group is turned on, off or dimmed by tapping or holding the switch a differing amount of times.
If you 

associate 

Z-Wave devices into Group 2, you can turn those devices on and off by tapping the switch on or

off 

twice

. You can brighten or dim devices by tapping the switch on or off once and then holding the switch. The load

attached to the ZRW113 is not affected.
If you associate

 

Z-Wave devices into Group 3, you can turn those devices on or off by tapping the switch on or off

three times

. You can brighten or dim devices by tapping the switch on or off twice and then holding the switch. The

load attached to the ZRW113 is not affected.
You can associate up to 

5

 Z-Wave devices into 

each

 of these groups.

For instructions on how to  “associate” a Z-Wave device into one of these groups, refer to your wireless controller
instructions. (If you are using the ZTH100 controller, refer to the Setup Menu, Association section).
A NOTE ABOUT DIMMING:  If you combine Z-Wave enabled dimmers and other types of Z-Wave devices in a group,
place a Z-Wave enabled dimmer into the empty group 1

st

 to ensure that the dimming operates correctly.

Configuration

The ZRW113 supports the Configuration command.

The ZRW113 can be configured to operate slightly differently than how it works when you first install it. Using the
Configuration command you can configure the following:
You can use a ZTH100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)

Set Ignore Start Level Bit When Transmitting Dim Commands

The ZRW113 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level
embedded in it.  A dimmer receiving this command will start dimming from that start level if this bit is set to 0.
If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.

•  Parameter No: 1
•  Length: 1 Byte
•  Valid Values  = 0 or 1 (default 1)

 Night Light

The LED on the ZRW113 will by default, turn ON when the load attached is turned ON. To make the LED turn
ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.

•  Parameter No: 3
•  Length: 1 Byte
•  Valid Values = 0 or 1 (default 0)

 Invert Switch

To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1.

•  Parameter No: 4
•  Length: 1 Byte
•  Valid Values = 0 or 1 (default 0)

LED Transmission Indication

The ZRW113 will flicker its LED when it is transmitting to any of its 2 groups.  This flickering can be set to
not flicker at all (set to 0), to flicker the entire time it is transmitting (set to 1), or to flicker for only 1 second
when it begins transmitting (set to 2). By default, the ZRW113 is set to flicker for only 1 second.

•   

Parameter 19

•   

Length: 1 Byte

•   

Valid Values = 0 , 1, 2 (default 2)

Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set
command. See your controller’s instructions on how to do this (and if it supports it).
All Configuration commands will be reset to their default state when the ZRW113 is RESET from the Z-Wave system.

Содержание ZRW113

Страница 1: ...wherepurchased DANGER SHOCK HAZARD Read and understand these instructions before installing This device is intended for installation in accordance with the National Electric code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada It is recommended that a qualified electrician perform this installation Make sure the load controlled by the swit...

Страница 2: ...turns the load attached ON Tapping bottom of switch turns the load attached OFF Pressing and holding switch does not effect the load attached but will allow dimming and brightening of Z Wave dimmers if associated to the ZRW113 see below for details LED indication The LED on the ZRW113 will turn on when the load attached is ON However the LED can be user configured to turn ON when the load attached...

Страница 3: ...it works when you first install it Using the Configurationcommandyoucanconfigurethefollowing You can use a ZTH100 to send Configuration commands Refer to the Setup Menu Configuration section Set Ignore Start Level Bit When Transmitting Dim Commands The ZRW113 can send Dim commands to Z Wave enabled dimmers The Dim command has a start level embedded in it A dimmer receiving this command will start ...

Страница 4: ...nfromvariouslocations WARRANTY For warranty and general product information visit our web site at www act solutions com ABOUT ZRW113 S CERTIFICATION The ZRW113 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmf...

Отзывы: