Smart IP Button
(IPBTN) Installation
Advanced Network Devices
•
3820 Ventura Dr. Arlington Hts. IL 60004
847-463-
2237 •
2
v2.2
blink_ms_output_gpio0="500" />
<GPIO_callback
send_activations_only="1" />
<Indicate
indicate_gpo="0"
trying_action="blink"
success_action="pulse" />
REGISTRED SIP CALL
Register the Smart IP Button device to an SIP server
to call an SIP phone or ring a group.
Configuration File Parameters
SIPConfig tag (values included for example):
<SIPConfig
push_to_talk_ip1="301"
/>
Web Server Settings
•
Go to
Device Settings
→
SIP
.
•
Under
SIP GPIO Input Action Settings
, set
Push-to-Talk 1
to the SIP extension the button
should call.
•
Select
Save and Apply
to save changes.
DIRECT SIP CALL
Call a SIP phone directly without registration to a
SIP server.
Configuration File Parameters
SIPConfig tag (values included for example):
<SIPConfig
push_to_talk_ip1="sip:
"
/>
Web Server Settings
•
Go to
Device Settings
→
SIP
.
•
Under
SIP GPIO Input Action Settings
, set
Push-to-Talk 1
to the SIP extension the button
should call.
•
Select
Save and Apply
to save changes.
PUSH AND HOLD SIP CALL
In addition to the Push-to-Talk call, configure a
second action (registered or direct SIP call) to dial
a different SIP extension when holding the button
for a specified time or longer.
Configuration File Parameters
SIPConfig tag (values included for example):
<SIPConfig
push_to_talk_ip1_alt="301"
push_to_talk_ip1_alt_ms="2000"
/>
Web Server Settings
•
Go to
Device Settings
→
SIP
.
•
Under
SIP GPIO Input Action Settings
, set
Push-to-Talk 1 Alternate
to the SIP extension
the button should call when held for the
desired duration.
•
Set
Push-to-Talk 1 Alternate Hold Time
to the
desired duration (in milliseconds) to hold the
button to trigger the call.
•
Select
Save and Apply
to save changes.
HTTP CALLBACK
Send an HTTP GET to IPClockWise or a third-party
software solution.
Configuration File Parameters
GPIO_callback tag (value included for example):
<GPIO_callback
url="
http://10.10.7.168:8089/
"
/>
Web Server Settings
•
Go to
Device Settings
→
Servers
•
Set
GPIO Callback URL
to the HTTP string.
•
Select
Save and Apply
to save changes. See the
IPClockWise manual to configure an alert to
trigger on this callback.
RESOURCES
SIP Configuration:
https://www.ipspeaker.com/support30/help/settin
gs.html#sip
User Support:
https://www.anet.com/user-support/
AND Limited Warranty:
https://www.anetd.com/warranty/
Legal Disclaimer: