background image

Smart IP Button 

(IPBTN) Installation 

Advanced Network Devices 

• 

3820 Ventura Dr. Arlington Hts. IL 60004 

[email protected]

 

• 

 847-463-

2237 •

 

www.anetd.com/

 

 

1

 

v2.2 

 

 
 
 
 

MOUNT THE BUTTON DEVICE 

 

Use device to mark installation location.  

 

Choose  the  best  location  and  orientation  to 
make the push button easy to access by the user, 
as well as to connect the network cable. 

 

Secure  device  using  mounting  hardware 
appropriate for the installation surface. 

 

Drywall:  #8-32  steel screw x  1-5/8"  min.  length 
fastened  to  a  75  lbs.  rated  drywall  anchor,  or 
similar

 

 

Concrete:  #8-32  steel screw x  5/8"  min.  length 
fastened  to  a  8-32  concrete  anchor  with  9/16" 
min. length, or similar

 

CONNECT TO THE NETWORK  

 

Connect a network cable (CAT 5 or better) to the 
RJ-45 port (PoE/PoE+).  

 

Connect the other end of the network cable to 
an LPS (Limited Power Source) PoE (Power over 
Ethernet)  network  switch  or  PoE  injector  on  a 
network with a DHCP server. 

ACCESS THE DEVICE 

Use one of these ways to access the device: 

 

Enter the IP address assigned by the DHCP server 
in your browser. 

 

Enter the 

IPv6 link-local address in your browser, 

formatted 

as 

http://[fe80::2246:f9ff:feXX:XXXX]

  (XX:XXXX  = 

last 6 digits of MAC address).

 

 

Double-click  on  the  device  in  the  IPClockWise 

Endpoints list to open the web server interface.

 

 

For  third-party  software  application,  consult 
guide  for  access  method  (often  uses 
configuration file).

 

CONFIGURE THE BUTTON 

 

Set up the button to trigger notifications, alerts, 
or other signal (see next page). 

 

Consult  the  IPClockWise  User  Manual  
(available 

on 

the 

Customer 

Portal 

www.anetd.com/portal/

) 

or 

third-party 

software guide for further instructions. 

 

Test before putting it into service. 

OPERATION 

The front panel blue LED provides feedback on a 
button  push.   The  LED  flashes  upon  the  initial 
button press. Once the device then connects to a 
SIP  phone  or  HTTP  Callback  server,  the  LED  will 
stop  flashing  and  remain  on  solid  for  at  least  5 
seconds.

 

CONFIGURATION OPTIONS 

The device ships with default settings: 

SIP Mode

 

 

 

 

 

"Button" 

Push-to-Talk 1 Trigger Only 

 

"Yes”

 

Activate GPIO 0 During Active Call  

“Yes”

  

Send Activations Only 

 

 

“Yes”

 

GPIO 0 Output Pulse Time

       

 

“5000”

 

GPIO 0 Output Blink Period         

“500”

 

Indicate GPO      

 

 

 

“0”

 

Indicate Trying Action 

 

 

“Blink”

 

Indicate Success Action    

 

“Pulse”

 

Configuration File Setup 

<SIPConfig 
  SIP_mode="button" 
  push_to_talk_ip1_trigger_mode="1" 
  gpio0_when_active_call="1" /> 
<GPIO  
  pulse_ms_output_gpio0="5000" 

Отзывы: